scholarly journals Automatic Self-Calibration of Suspended Under-Actuated Cable-Driven Parallel Robot using Incremental Measurements

Author(s):  
Edoardo Idá ◽  
Jean-Pierre Merlet ◽  
Marco Carricato
Author(s):  
Philipp Last ◽  
Annika Raatz ◽  
Ju¨rgen Hesselbach ◽  
Nenad Pavlovic ◽  
Ralf Keimer

Model based geometric calibration is well known to be an efficient way to enhance absolute accuracy of robotic systems. Generally its application requires redundant measurements, which are achieved by external metrology equipment in most traditional calibration techniques. However, these methods are usually time-consuming, expensive and inconvenient. Thus, so-called self-calibration methods have achieved attention from researchers, which either use internal sensors or rely on mechanical constraints instead. In this paper a new self-calibration technique is presented for parallel robots which is motivated by the idea of constrained calibration. The new approach utilizes a special machine component called the adaptronic swivel joint in order to achieve the required redundant information. Compared to similar approaches it offers several advantages. The new calibration scheme is described and verified in simulation studies using a RRRRR-structure as an example.


2005 ◽  
Vol 173 (4S) ◽  
pp. 121-121
Author(s):  
Hari Siva Gurunadha Rao Tunuguntla ◽  
P.V.L.N. Murthy ◽  
K. Sasidharan

Robotics ◽  
2020 ◽  
Vol 10 (1) ◽  
pp. 7
Author(s):  
Ferdaws Ennaiem ◽  
Abdelbadiâ Chaker ◽  
Juan Sebastián Sandoval Arévalo ◽  
Med Amine Laribi ◽  
Sami Bennour ◽  
...  

This paper deals with the design of an optimal cable-driven parallel robot (CDPR) for upper limb rehabilitation. The robot’s prescribed workspace is identified with the help of an occupational therapist based on three selected daily life activities, which are tracked using a Qualisys motion capture system. A preliminary architecture of the robot is proposed based on the analysis of the tracked trajectories of all the activities. A multi-objective optimization process using the genetic algorithm method is then performed, where the cable tensions and the robot size are selected as the objective functions to be minimized. The cables tensions are bounded between two limits, where the lower limit ensures a positive tension in the cables at all times and the upper limit represents the maximum torque of the motor. A sensitivity analysis is then performed using the Monte Carlo method to yield the optimal design selected out of the non-dominated solutions, forming the obtained Pareto front. The robot with the highest robustness toward the disturbances is identified, and its dexterity and elastic stiffness are calculated to investigate its performance.


Sign in / Sign up

Export Citation Format

Share Document