Anticoagulation Management in Atrial Fibrillation Catheter Ablation

2017 ◽  
pp. 239-243
Author(s):  
Brian Cryder
2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
N Poci ◽  
D Gjermeni ◽  
V Kuehlkamp

Abstract Background Catheter ablation of atrial fibrillation is known for the combining risks of thromboembolism (TE) and major bleedings. This urges a better understanding and optimization of the intraprocedural anticoagulation management. Differences in unfractionated heparin (UFH) requirements and anticoagulation time (ACT) levels between patients on different uninterrupted oral anticoagulation (OAC) agents have been studied. However, the clinical relevance, in terms of periprocedural TE and bleeding events, of UFH administration according to ACT monitoring among patients on different OAC agents, needs to be addressed. Objective To evaluate how the ACT monitoring and differences in intraprocedural UFH requirements among different anticoagulant agents, may translate to clinical outcome, in terms of periprocedural incidence of thromboembolic and bleeding events. Methods We retrospectively studied 1571 cases who underwent catheter ablation for atrial fibrillation between January 2011 and May 2017. Cases were on an uninterrupted oral OAC therapy of Vitamin K Antagonists (VKA)(713), Rivaroxaban (RG)(385), Dabigatran (DG)(260), Apixaban (AG)(192) and Edoxaban (EG)(21). First ACT measurements after the initial bolus of UFH (1ehz748.0610U), mean ACT measurements, total UFH doses/kg (Body Weight)/min (duration of procedure) and incidence of major periprocedural events were compared among the above OAC groups. Results The mean ACT (sec) was significantly lower in the AG and greater in the VKA (313,7±47 vs 340,5±49, p<0,001). Significantly lower UFH doses (U/kg/min) were required to reach the target ACT in VKA compared to RG, DG, AG and EG (0,69±0,4 vs 1,41±0,76; 1,42±0,7; 1,63±0,8; 1,37±0,4 respectively, p<0,001) The proportion of patients who achieved a target ACT value within 30 minutes after the fixed first UFH Bolus of 10 000 U was significantly lower in DG and AG compared to VKA, EG and RG group (51,5% and 49% vs 53%, 71,4%, and 61,8% respectively p=0,005). The incidence of periprocedural TE events and bleedings showed no significant difference among OAC groups. However, the 22 patients with a periprocedural TE event had significantly lower UFH doses (U)/ Duration of catheter ablation (min) compared to the ones without periprocedural TE (62,71±44,5 vs 94,4±66,4, p=0,026), despite equivalent mean ACT values between these two groups. Patients with a periprocedural TE had also a significantly older Age (69,6±10 vs 64±10 p=0,01, higher CHADSVASC Score (3,64±1,76 vs 2,63±1,7 p=0,006), longer duration of procedure (188,9±79,1 vs 144,9±57 p=0,0001) and higher pre-Ablation INR values (2,2±0,6 vs 1,7±0,6 p=0,002). Conclusions The average UFH doses required to reach the target ACT were lower in VKA than in NOAC- groups. The incidence of periprocedural TE events and bleedings was equivalent among OAC groups. Patients with TE showed a lower UFH requirement compared to no-TE group, with both groups having mean ACT ≥300 sec.


EP Europace ◽  
2021 ◽  
Author(s):  
Derek Chew ◽  
Jonathan P Piccini

Abstract Catheter ablation is superior to antiarrhythmic therapy for the reduction of symptomatic atrial fibrillation (AF), recurrence, and burden. The possibility of a true ‘rhythm’ control strategy with catheter ablation has re-opened the debate on rate vs. rhythm control and the subsequent impact on stroke risk. Some observation studies suggest that successful AF catheter ablation and maintenance of sinus rhythm are associated with a decrease in stroke risk, while the CABANA trial had demonstrated no apparent reduction. Other observational studies have demonstrated increased stroke risk when oral anticoagulation (OAC) is discontinued after catheter ablation. When and in whom OAC can be discontinued after ablation will need to be determined in properly conducted randomized control trials. In this review article, we discuss our current understanding of the interactions between AF, stroke, and anticoagulation following catheter ablation. Specifically, we discuss the evidence for the long-term anticoagulation following successful catheter ablation, the potential for OAC discontinuation with restoration of sinus rhythm, and novel approaches to anticoagulation management post-ablation.


Circulation ◽  
2014 ◽  
Vol 129 (25) ◽  
pp. 2638-2644 ◽  
Author(s):  
Luigi Di Biase ◽  
J. David Burkhardt ◽  
Pasquale Santangeli ◽  
Prasant Mohanty ◽  
Javier E. Sanchez ◽  
...  

Circulation ◽  
2018 ◽  
Vol 138 (6) ◽  
pp. 627-633 ◽  
Author(s):  
Anne-Céline Martin ◽  
Anne Godier ◽  
Kumar Narayanan ◽  
David M. Smadja ◽  
Eloi Marijon

Catheter ablation has gained a prominent role in the management of atrial fibrillation (AF), with recent data providing positive evidence on hard outcomes, including hospitalization and mortality. Ablation, however, exposes the patient to a rather unique situation, combining risks for both major bleeding and thromboembolic events. In this setting, the critical importance of rigorous anticoagulation during the procedure has been underlined, and the latest international guidelines now recommend performing AF catheter ablation with uninterrupted non-vitamin K antagonist oral anticoagulants (NOACs) and concomitant administration of unfractionated heparin adjusted to achieve and maintain a target activated clotting time of ≥300 seconds. Whereas observational studies and randomized controlled trials support the safety and efficacy of uninterrupted NOAC strategy for AF catheter ablation, recent experiences have questioned this point, showing a greater unfractionated heparin requirement in NOAC-treated patients compared with vitamin K antagonists–treated patients to achieve the target activated clotting time. Important gaps in evidence regarding optimal intraprocedural anticoagulation management need to be acknowledged. A thorough appreciation of the physiology of anticoagulation during AF catheter ablation and the relevant differences between vitamin K antagonists and NOACs is required, while also understanding the limitations of activated clotting time measurement with regard to accurate intraprocedural anticogulation monitoring. This review aims to provide a critical look at this relatively ignored aspect of AF catheter ablation, especially pitfalls in NOAC monitoring, and to identify gaps in knowledge that need to be addressed in the near future.


Sign in / Sign up

Export Citation Format

Share Document