P.1.17 Follow-up after right atrial multilinear catheter ablation of atrial fibrillation

EP Europace ◽  
2003 ◽  
Vol 4 ◽  
pp. A37
Author(s):  
C PERINGS
EP Europace ◽  
2003 ◽  
Vol 4 (Supplement_1) ◽  
pp. A37-A37
Author(s):  
C. Perings ◽  
S. Dierkes ◽  
M.G. Hennersdorf ◽  
B.E. Strauer

2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
A Katbeh ◽  
T De Potter ◽  
P Geelen ◽  
S Nagumo ◽  
Z Balogh ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Public Institution(s). Main funding source(s): International PhD Program in Cardiovascular Pathophysiology and Therapeutics CardioPaTh Background Radio-frequency catheter ablation (CA) is associated with changes of left atrial (LA) structure and function. However, there is limited knowledge regarding the long-term impact of successful CA on atrial morphology and mechanics. Purpose To compare the time course of LA and right atrial (RA) performance in patients with paroxysmal atrial fibrillation (AF) undergoing the first CA. Methods This prospective study included 89 consecutive patients (age:62 ± 21 years; 66% male) with a history of symptomatic AF who underwent successful CA. All patients maintained SR during follow-up. A comprehensive echocardiographic examination was performed 1- day before and 1-day, 3-month and 12-month after CA. The reservoir and contractile strain for both LA and RA (LAS, RAS), and left intra-atrial mechanical dispersion (LAMD) were assessed using 2D speckle tracking echocardiography in all three apical views (only 4CH view for RAS and LAMD). Results At baseline, all patients with paroxysmal AF showed a significant reduction of reservoir and contractile LAS and RAS compared with controls (all p < 0.01). CA was associated with a significant decrease in reservoir and contractile LAS while no significant difference was observed for RAS. At 3-month follow-up, the LAS showed full recovery, whereas the RAS did not show any significant change from 1-day post CA values. At 12-month follow-up, both reservoir and contractile LAS showed further improvement compared to baseline and 3-month values. LAMD derived from the LA strain curve followed a similar trend. Although the RA motion was not affected in the early phase, both reservoir and contractile RAS showed a significant increase between 3-month and 12-month follow-up. Conclusion Although the radio-frequency CA affected negatively LA performance in the acute phase, it has a long-term positive impact on both left and right atrial function. Figure Time course of reservoir and contractile LAS and RAS at Baseline, 1-day, 3-month and 12-month follow-up. Abstract Figure.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
O.M Aldaas ◽  
F Lupercio ◽  
C.L Malladi ◽  
P.S Mylavarapu ◽  
D Darden ◽  
...  

Abstract Background Catheter ablation improves clinical outcomes in symptomatic atrial fibrillation (AF) patients with heart failure (HF) with reduced ejection fraction (HFrEF). However, the role of catheter ablation in HF patients with a preserved ejection fraction (HFpEF) is less clear. Purpose To determine the efficacy of catheter ablation of AF in patients with HFpEF relative to those with HFrEF. Methods We performed an extensive literature search and systematic review of studies that compared AF recurrence at one year after catheter ablation of AF in patients with HFpEF versus those with HFrEF. Risk ratio (RR) 95% confidence intervals were measured using the Mantel-Haenszel method for dichotomous variables, where a RR<1.0 favors the HFpEF group. Results Four studies with a total of 563 patients were included, of which 312 had HFpEF and 251 had HFrEF. All patients included were undergoing first time catheter ablation of AF. Patients with HFpEF experienced similar recurrence of AF one year after ablation on or off antiarrhythmic drugs compared to those with HFrEF (RR 0.87; 95% CI 0.69–1.10, p=0.24), as shown in Figure 1. Recurrence of AF was assessed with electrocardiography, Holter monitoring, and/or event monitoring at scheduled follow-up visits and final follow-up. Conclusion Based on the results of this meta-analysis, catheter ablation of AF in patients with HFpEF appears as efficacious in maintaining sinus rhythm as in those with HFrEF. Funding Acknowledgement Type of funding source: None


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
T Kato ◽  
K Usuda ◽  
H Tada ◽  
T Tsuda ◽  
K Takeuchi ◽  
...  

Abstract Background High plasma B-Type natriuretic peptide (BNP) level is associated with cardiac events or stroke in patients with atrial fibrillation (AF). However, it is still unknown whether BNP predicts worse clinical outcomes after catheter ablation ofAF. Purpose We aimed to see if plasma BNP level is associated with major adverse cardiac and cerebrovascular events (MACCE) after catheter ablation of AF. Methods We retrospectively analyzed 1,853 participants (73.1% men, mean age 63.3±10.3 years, 60.7% paroxysmal AF) who received first catheter ablation of AF with pre-ablation plasma BNP level measurement and completed follow-up more than 3 months after the procedure from AF Frontier Ablation Registry, a multicenter cohort study in Japan. We evaluated an association between plasma BNP level before catheter ablation and first MACCE in cox-regression hazard models adjusted for known risk factors. MACCE were defined as stroke/transient ischemic attack (TIA), cardiovascular events or all-cause death. Results The mean plasma BNP level was 120.2±3.7 pg/mL. During a mean follow-up period of 21.9 months, 57 patients (3.1%) suffered MACCE (ischemic stroke 8 [14.0%], hemorrhagic stroke 5 [8.8%], TIA 5 [8.8%], hospitalization for heart failure 11 [19.2%], acute coronary syndrome 9 [15.8%], hospitalization for other cardiovascular events 8 [14.0%] and all-cause death 11 [19.2%]). Plasma BNP level of patients with MACCE were significantly higher than those without MACCE (291.7±47.0 vs 114.7±3.42 pg/mL, P<0.001). Multivariate analysis revealed that plasma BNP level (hazard ratio [HR] per 10 pg/mL increase 1.014; 95% confidence interval [CI] 1.005–1.023; P=0.001), baseline age (HR 1.052; 95% CI 1.022–1.084; P=0.001), heart failure (HR 2.698; 95% CI 1.512–4.815; P=0.001), old myocardial infarction (HR 3.593; 95% CI 1.675–7.708; P=0.001) and non-ischemic cardiomyopathy (HR 2.676; 95% CI 1.337 - 5.355; P=0.005) were independently associated with MACCE. At receiver-operating characteristic curve analysis, plasma BNP level before catheter ablation ≥162.7 pg/mL was the best threshold to predict MACCE (area under the curve: 0.71). Kaplan-Meier curve analysis (Figure) showed that the cumulative incidence of MACCE was significantly higher in patients with a BNP ≥162.7 pg/mL than in those with a BNP below 162.7 pg/mL (HR 4.85; 95% CI 2.86–8.21; P<0.001). Conclusions Elevation of plasma BNP level was independently related to the increased risk of MACCE after catheter ablation ofAF. Funding Acknowledgement Type of funding source: Private company. Main funding source(s): Bristol-Meiers Squibb


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
M Pope ◽  
P Kuklik ◽  
A Briosa E Gala ◽  
M Leo ◽  
J Paisey ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Public hospital(s). Main funding source(s): Oxford Biomedical Research Centre Introduction Non-contact charge density mapping allows visualisation of whole chamber propagation during atrial fibrillation (AF). The identification of regions with repetitive or, conversely, more complex patterns of wavefront propagation may provide clues to mechanisms responsible for AF maintenance and lead to improved outcomes from catheter ablation. Our novel mapping approach based on signal recurrence plots has never been applied to whole chamber, bi-atrial recording of atrial fibrillation. Purpose To apply recurrence analysis to characterise whole chamber bi-atrial AF propagation. Methods Non-contact dipole signals from left and right atrial maps were obtained during simultaneous bi-atrial charge density mapping of AF. Signals were converted to phase and mean phase coherence calculated for the generation of recurrence distance matrices for the whole chamber and each anatomical region (6x LA and 4x RA) over the 30-second recording duration, where a value of 1 (purple, see figure panel A) represents uniform repetitive conduction, and 0 (red), irregular, non-repetitive activity. Whole chamber and regional mean recurrence values were calculated and correlated with the frequency of wavefronts of localised irregular activation patterns. Results Maps were obtained prior to ablation in 21 patients (5 paroxysmal (pAF), 16 persistent AF (persAF)) undergoing de-novo catheter ablation procedures. Whole chamber recurrence was higher in patients with pAF (0.40 ± 0.08) than persAF (0.34 ± 0.05), p < 0.0005. There was an inverse correlation between regional recurrence values and the number of localised irregular activations detected (-0.7021, p < 0.0005, figure panel B) with the lateral LA and anterior RA demonstrating the highest recurrence values in each chamber (figure panel C). Conclusion Use of recurrence distance matrices characterises global AF propagation phenotypes. Regional values are inversely correlated with the frequency of localised irregular activation patterns identified demonstrating an anatomic dependence in the level of AF propagation complexity, greatest in the anterior LA and septal RA. Comparison of strategies targeting regions with maximal vs. minimal values during catheter ablation may define an optimal approach to treatment of persistent AF. Abstract Figure. Recurrence abstract figure


2015 ◽  
Vol 79 (12) ◽  
pp. 2576-2583 ◽  
Author(s):  
Marina Antolini ◽  
Alessandro Brustio ◽  
Mara Morello ◽  
Federica Bongiovanni ◽  
Cristina Fornengo ◽  
...  

2019 ◽  
Vol 29 (5) ◽  
pp. 643-648 ◽  
Author(s):  
Jindong Chen ◽  
Hao Wang ◽  
Mengmeng Zhou ◽  
Liang Zhao

AbstractBackground:To assess the effectiveness of radiofrequency catheter ablation for lone atrial fibrillation in young adults.Methods:This single-centre, retrospective, observational study enrolled 75 consecutive patients (86.7% men) under 35 (median, 30) years old with lone atrial fibrillation (68% paroxysmal, 26.7% persistent, and 5.3% long-standing persistent) without other cardiopulmonary diseases who underwent catheter ablation between April 2009 and May 2017. Procedural endpoints were circumferential pulmonary vein ablation for atrial fibrillation with pulmonary vein trigger, and target ablation or bidirectional block of lines and disappearance of complex fractionated atrial electrograms for atrial fibrillation with clear and unclear non-pulmonary vein triggers, respectively.Results:Main study outcome was rate of survival free from atrial tachyarrhythmia recurrence, which at median 61 (range, 5–102) months follow-up was 62.7% (64.7 and 58.3% for paroxysmal and non-paroxysmal atrial fibrillation, respectively) after single ablation, and 69.3% (68.6 and 70.8% for paroxysmal and non-paroxysmal atrial fibrillation, respectively) after mean 1.2 ablations (two and three ablations in 11 and 2 patients, respectively). In multivariate analysis, non-pulmonary vein trigger was a significant independent predictor of recurrent atrial tachyarrhythmia (OR, 10.60 [95%CI, 2.25–49.96]; p = 0.003). There were no major periprocedural adverse events.Conclusions:In patients under 35 years old with lone atrial fibrillation, radiofrequency catheter ablation appeared effective particularly for atrial fibrillation with pulmonary vein trigger and regardless of left atrial size or atrial fibrillation duration or type. Atrial tachyarrhythmia recurrence after multiple ablations warrants further study.


Sign in / Sign up

Export Citation Format

Share Document