Optical Coherence Tomography: Emerging In Vivo Optical Biopsy Technique for Oral Cancers

2018 ◽  
pp. 217-237
Author(s):  
Prashanth Panta ◽  
Chih-Wei Lu ◽  
Piyush Kumar ◽  
Tuan-Shu Ho ◽  
Sheng-Lung Huang ◽  
...  
2001 ◽  
Author(s):  
Wolfgang Drexler ◽  
Ravi K. Ghanta ◽  
Joel S. Schuman ◽  
Tony H. Ko ◽  
Uwe Morgner ◽  
...  

2020 ◽  
Vol 132 (6) ◽  
pp. 1907-1913 ◽  
Author(s):  
Anne E. Carolus ◽  
Marcel Lenz ◽  
Martin Hofmann ◽  
Hubert Welp ◽  
Kirsten Schmieder ◽  
...  

OBJECTIVEBecause of their complex topography, long courses, and small diameters, peripheral nerves are challenging structures for radiological diagnostics. However, imaging techniques in the area of peripheral nerve diseases have undergone unexpected development in recent decades. They include MRI and high-resolution sonography (HRS). Yet none of those imaging techniques reaches a resolution comparable to that of histological sections. Fascicles are the smallest discernable structure. Optical coherence tomography (OCT) is the first imaging technique that is able to depict a nerve’s ultrastructure at micrometer resolution. In the current study, the authors present an in vivo assessment of human peripheral nerves using OCT.METHODSOCT measurement was performed in 34 patients with different peripheral nerve pathologies, i.e., nerve compression syndromes. The nerves were examined during surgery after their exposure. Only the sural nerve was twice examined ex vivo. The Thorlabs OCT systems Callisto and Ganymede were used. For intraoperative use, a hand probe was covered with a sterile foil. Different postprocessing imaging techniques were applied and evaluated. In order to highlight certain structures, five texture parameters based on gray-level co-occurrence matrices were calculated according to Haralick.RESULTSThe intraoperative use of OCT is easy and intuitive. Image artifacts are mainly caused by motion and the sterile foil. If the artifacts are kept at a low level, the hyporeflecting bundles of nerve fascicles and their inner parts can be displayed. In the Haralick evaluation, the second angular moment is most suitable to depict the connective tissue.CONCLUSIONSOCT is a new imaging technique that has shown promise in peripheral nerve surgery for particular questions. Its resolution exceeds that provided by recent radiological possibilities such as MRI and HRS. Since its field of view is relatively small, faster acquisition times would be highly desirable and have already been demonstrated by other groups. Currently, the method resembles an optical biopsy and can be a supplement to intraoperative sonography, giving high-resolution insight into a suspect area that has been located by sonography in advance.


Endoscopy ◽  
2000 ◽  
Vol 32 (10) ◽  
pp. 743-749 ◽  
Author(s):  
S. Jäckle ◽  
N. Gladkova ◽  
F. Feldchtein ◽  
A. Terentieva ◽  
B. Brand ◽  
...  

Cancers ◽  
2020 ◽  
Vol 12 (9) ◽  
pp. 2376
Author(s):  
Ping-Hsien Chen ◽  
Hung-Yi Lee ◽  
Yi-Fen Chen ◽  
Yi-Chen Yeh ◽  
Kuo-Wei Chang ◽  
...  

Detection of oral dysplastic and early-stage cancerous lesions is difficult with the current tools. Half of oral cancers are diagnosed in a late stage. Detection of early stromal change to predict malignant transformation is a new direction in the diagnosis of early-stage oral cancer. The application of new optical tools to image stroma in vivo is under investigation, and polarization-sensitive optical coherence tomography (PS-OCT) is potentially one of those tools. This is a preliminary study to sequentially image oral stromal changes from normal, hyperplasia, and dysplasia to early-stage cancer by PS-OCT in vivo. We used 4-Nitroquinoline-1-oxide drinking water to induce dysplasia and early-stage oral cancer in 19 K14-EGFP-miR-211-GFP transgenic mice. A total of 8 normal, 12 hyperplastic, 11 dysplastic, and 4 early-stage cancerous lesions were enrolled. A new analytic process of PS-OCT imaging was proposed, called an en-face birefringence map. From the birefringence map, the sensitivity, specificity, positive predictive value, and negative predictive values to detect dysplasia and early-stage cancer were 100.00%, 95.00%, 93.75%, and 100.00%, respectively, and the kappa value of these images between two investigators was 0.942. The mean size of malignant lesions detected in this study is 1.66 ± 0.93 mm. This pilot animal study validates the use of PS-OCT to detect small and early-stage oral malignancy with high accuracy and consistency.


2004 ◽  
Vol 171 (4S) ◽  
pp. 68-68 ◽  
Author(s):  
Markus D. Sachs ◽  
Dmitry Daniltchenko ◽  
Eva Lankenau ◽  
Frank Koenig ◽  
Gerion Huettmann ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 808
Author(s):  
Max Philipp Brinkmann ◽  
Nikolas Xavier Kibele ◽  
Michelle Prasuhn ◽  
Vinodh Kakkassery ◽  
Mario Damiano Toro ◽  
...  

Optical coherence tomography angiography (OCTA) is a non-invasive tool for imaging and quantifying the retinal and choroidal perfusion state in vivo. This study aimed to evaluate the acute effects of isometric and dynamic exercise on retinal and choroidal sublayer perfusion using OCTA. A pilot study was conducted on young, healthy participants, each of whom performed a specific isometric exercise on the first day and a dynamic exercise the day after. At baseline and immediately after the exercise, heart rate (HR), mean arterial pressure (MAP), superficial capillary plexus perfusion (SCPP), deep capillary plexus perfusion (DCPP), choriocapillaris perfusion (CCP), Sattlers’s layer perfusion (SLP), and Haller’s layer perfusion (HLP) were recorded. A total of 34 eyes of 34 subjects with a mean age of 32.35 ± 7.87 years were included. HR as well as MAP increased significantly after both types of exercise. Both SCPP and DCPP did not show any significant alteration due to isometric or dynamic exercise. After performing dynamic exercise, CCP, SLP, as well as HLP significantly increased. Changes in MAP correlated significantly with changes in HLP after the dynamic activity. OCTA-based analysis in healthy adults following physical activity demonstrated a constant retinal perfusion, supporting the theory of autoregulatory mechanisms. Dynamic exercise, as opposed to isometric activity, significantly changed choroidal perfusion. OCTA imaging may represent a novel and sensitive tool to expand the diagnostic spectrum in the field of sports medicine.