Chromatographic method of quantitative determination of the composition of gases in high-boiling liquid products

1971 ◽  
Vol 7 (3) ◽  
pp. 231-233
Author(s):  
E. N. Shtern ◽  
R. A. Lipshtein ◽  
V. V. Kulikova
1971 ◽  
Vol 54 (3) ◽  
pp. 711-712
Author(s):  
Martha Fuzesi

Abstract A gas chromatographic method is described for the quantitative determination of N-butyl-N-ethyl-α,α,α-trifluoro-2,6-dinitro-p-tolindine and α,α,α-trifluoro-2,6-dinitro-N,N-dipropyI-p-toluidine herbicides in formulations. The sample is extracted with benzene, and equal amounts of sample and reference solution in the same concentration range are analyzed by gas chromatography, using an electron capture detector and an SE-30/Diatoport S column. The method has been applied successfully to laboratory-prepared and commercial samples.


1974 ◽  
Vol 20 (2) ◽  
pp. 249-254 ◽  
Author(s):  
M A Evenson ◽  
G L Lensmeyer

Abstract A rapid, simple, accurate, and precise isothermal gas-chromatographic method is introduced for determination of methaqualone (2-methyl-3-o-tolyl-4(3H)-quinazolinone) in serum. A single extraction of 2 ml of serum, without derivative formation, will give adequate sensitivity for quantitation of therapeutic serum concentrations of the drug within 15 min. The method is free of interferences from biological substances, as well as from commonly used drugs. A non-drug internal standard compensates for variables in extraction, injection, and instrumental changes during analysis. The coefficient of variation, day-to-day, is 5.6%. Mean recovery of added methaqualone was 80%. To compensate for the nonquantitative yield and ensure accurate results, we prepared all analytical methaqualone standards in serum.


2004 ◽  
Vol 87 (4) ◽  
pp. 842-846 ◽  
Author(s):  
Cássia V Garcia ◽  
Clésio S Paim ◽  
Martin Steppe

Abstract Rabeprazole sodium is a proton pump inhibitor that covalently binds and inactivates the gastric parietal cell proton pump (H+/K+ ATPase). Little has been published about the quantitative determination of this drug. The aim of this research was to develop a new liquid chromatographic method for quantitative determination of rabeprazole in coated tablets. The system consisted of a Hypersil Keystone Betabasic C8 column (250 × 4.6 mm, 5 μm particle size), an isocratic acetonitrile–water (35 + 65) mobile phase at a flow rate of 1.0 mL/min, and a diode array detector set at 282 nm. The following validation parameters were evaluated: linearity, precision, accuracy, specificity, detection and quantitation limits, and robustness. The method showed good linearity in the concentration range of 10–70 μg/mL. The quantitation limit was 2.43 μg/mL, and the detection limit was 0.80 μg/mL. The intra- and interday precision data showed that the method has good reproducibility (relative standard deviation = 1.03). Accuracy and robustness were also evaluated, and the results were satisfactory. The mean recovery was 101.61%. The analysis of a placebo mixture demonstrated the method is also specific.


1972 ◽  
Vol 18 (11) ◽  
pp. 1343-1349 ◽  
Author(s):  
Rodney G Cooper ◽  
Mavis S Greaves ◽  
Goronwy Owen

Abstract An accurate method is described for the qualitative and quantitative determination of 11 barbiturates, glutethimide, and diphenylhydantoin in a single extract obtained from 1 ml of whole blood, which is extracted with ether at pH 2 and separately but simultaneously gas-liquid chromatographed on a selective (3% OV-17) and a nonselective (5% OV-1) column. Retention data are given. Results for barbiturate obtained by the Broughton [Biochem. J.63, 207 (1956)] spectrophotometric method and this gas-liquid chromatographic method are compared. Blood from more than 30 patients has been analyzed, and data are given to illustrate some of the findings.


1970 ◽  
Vol 53 (3) ◽  
pp. 566-568
Author(s):  
J E Paterson

Abstract A gas chromatographic method is described for the quantitative determination of dioxathion and chlorfenvinphos in emulsifiable concentrates and livestock dips. A convenient quantity of the emulsifiable formulation is dissolved in xylene and the aqueous dip is extracted with xylene for gas chromatographic analysis, using a mixed silicone oil stationary phase and a flame ionization detector. The coefficients of variation for the dioxathion and chlorfenvinphos determinations in the emulsifiable concentrate are 2.4 and 1.0%, respectively. Recoveries of the former from a fouled dip ranged from 97 to 103% and recoveries of the latter ranged from 92 to 97%.


Sign in / Sign up

Export Citation Format

Share Document