Detection limit of technetium in99Tc(γ,γ′)99mTc radioactivation analysis in the presence of molybdenum

1991 ◽  
Vol 155 (6) ◽  
pp. 435-443 ◽  
Author(s):  
M. Yagi ◽  
T. Sekine ◽  
K. Yoshihara
2013 ◽  
Vol 12 (7) ◽  
pp. 460-465
Author(s):  
Sameer Amereih ◽  
Zaher Barghouthi ◽  
Lamees Majjiad

A sensitive colorimetric determination of fluoride in drinking water has been developed using a polymeric zirconium complex of 5-(2-Carboxyphenylazo)-8-Hydroxyquinoline as fluoride reagents. The method allowed a reliable determination of fluoride in range of (0.0-1.5) mg L-1. The molar absorptivity of the complex formation is 7695 ± 27 L mol-1 cm-1 at 460 nm. The sensitivity, detection limit, quantitation limit, and percentage recovery for 1.0 mg L-1 fluoride for the proposed method were found to be 0.353 ± 0.013 μg mL-1, 0.1 mg L-1, 0.3 mg L-1, and 101.7 ± 4.1, respectively.


Author(s):  
J. J. Domanski ◽  
P. L. Haire ◽  
T.J. Sheets

AbstractAverage residue Ievels of DDT + TDE in flue-cured tobacco decreased from 6.1 ppm in 1970 to 0.85 ppm in 1972. DDT + TDE residues in Burley also dropped sharply from previous levels. In 1972 one sample from Kentucky contained 8.17 ppm; all other Burley samples were less than 0.25 ppm. DDT + TDE residues also declined in fire-cured and air-cured types; of these samples Tennessee dark air-cured tobacco contained the highest average residue (3.5 ppm of DDT + TDE). In 1972 over 90 % of the flue-cured samples were positive for toxaphene. Since each of our samples was a composite of tobacco from 10 farmers, we cannot conclude from this result that 90 % of the individual piles contained toxaphene. Significant amounts of toxaphene were found in other types also; for example, 50 % of the 1972 Burley samples had toxaphene concentrations greater than 0.5 ppm. Average endosulfan levels decreased between 1970 and 1972 in flue-cured and Burley tobaccos. However, in all of the dark air and dark fire-cured samples from Tennessee endosulfan residues exceeded 5 ppm. Average endrin residues were at or near the low detection limit in alI samples except fire-cured and dark air-cured tobacco from Tennessee; these averaged 0.26 and 0.17 ppm, respectively.


2020 ◽  
Vol 16 ◽  
Author(s):  
Ikko Mikami ◽  
Eri Shibayama ◽  
Kengo Takagi

Background: Determination of a reducing substance based on the reaction between Ce(IV) and a reducing substance and fluorescence detection of Ce(III) generated has been reported as a selective and sensitive method. However, this method could not be applied to the determination of alcohol due to the low reaction rate of alcohol and Ce(IV). Objective: We found that thiosulfate catalytically enhanced reaction of alcohols (such as, methanol, ethanol, and propanol) and Ce(IV). Utilizing this effect, we developed a new method for the determination of alcohols. Results: In the presence of thiosulfate, an increase in fluorescence intensity was detected by injecting alcohol at concentrations of several millimolar, whereas it was not observed even at the concentration of 10% v/v (2 M for ethanol) in the absence of thiosulfate. The optimum detection conditions were determined to be 4.0 mM Ce(IV) sulfate and 0.50 mM thiosulfate, and the detection limit (S/N = 3) of ethanol under these conditions was 1 mM. In the calibration curves, changes in the slope were observed when the alcohol concentrations were approximately 10–25 mM. Using a thiosulfate solution containing ethanol as the reaction solution, a calibration curve without any change in slope was obtained, although the concentration of ethanol at the detection limit increased. The alcohols in the liquor and fuel were successfully analyzed using the proposed detection method as a postcolumn reaction. Conclusion: This new alcohol detection method using a versatile fluorescence detector can be applied to the postcolumn reaction of HPLC omitting need of time-consuming pretreatment processes.


2019 ◽  
Vol 15 (4) ◽  
pp. 502-510 ◽  
Author(s):  
Hakan Karadeniz ◽  
Arzum Erdem

Background: Anthrax Lethal Factor (ANT) is the dominant virulence factor produced by B. anthracis and is the major cause of death of infected animals. In this paper, pencil graphite electrodes GE were modified with single-walled and multi-walled carbon nanotubes (CNTs) for the detection of hybridization related to the ANT DNA for the first time in the literature. Methods: The electrochemical monitoring of label-free DNA hybridization related to ANT DNA was explored using both SCNT and MCNT modified PGEs with differential pulse voltammetry (DPV). The performance characteristics of ANT-DNA hybridization on disposable GEs were explored by measuring the guanine signal in terms of optimum analytical conditions; the concentration of SCNT and MCNT, the concentrations of probe and target, and also the hybridization time. Under the optimum conditions, the selectivity of probe modified electrodes was tested and the detection limit was calculated. Results: The selectivity of ANT probes immobilized onto MCNT-GEs was tested in the presence of hybridization of probe with NC no response was observed and with MM, smaller responses were observed in comparison to full-match DNA hybridization case. Even though there are unwanted substituents in the mixture samples containing both the target and NC in the ratio 1:1 and both the target and MM in the ratio 1:1, it has been found that ANT probe immobilized CNT modified graphite sensor can also select its target by resulting with 20.9% decreased response in comparison to the one measured in the case of full-match DNA hybridization case Therefore, it was concluded that the detection of direct DNA hybridization was performed by using MCNT-GEs with an acceptable selectivity. Conclusion: Disposable SCNT/MCNT modified GEs bring some important advantages to our assay including easy use, cost-effectiveness and giving a response in a shorter time compared to unmodified PGE, carbon paste electrode and glassy carbon electrode developed for electrochemical monitoring of DNA hybridization. Consequently, the detection of DNA hybridization related to the ANT DNA by MCNT modified sensors was performed by using lower CNT, probe and target concentrations, in a shorter hybridization time and resulting in a lower detection limit according to the SCNT modified sensors. In conclusion, MCNT modified sensors can yield the possibilities leading to the development of nucleic acid sensors platforms for the improvement of fast and cost-effective detection systems with respect to DNA chip technology.


1986 ◽  
Vol 51 (11) ◽  
pp. 2466-2472 ◽  
Author(s):  
Jiří Barek ◽  
Antonín Berka ◽  
Ludmila Dempírová ◽  
Jiří Zima

Conditions were found for the determination of 6-mercaptopurine (I) and 6-thioguanine (II) by TAST polarography, differential pulse polarography and fast-scan differential pulse voltammetry at a hanging mercury drop electrode. The detection limits were 10-6, 8 . 10-8, and 6 . 10-8 mol l-1, respectively. A further lowering of the detection limit to 2 . 10-8 mol l-1 was attained by preliminary accumulation of the determined substances at the surface of a hanging mercury drop.


1989 ◽  
Vol 54 (3) ◽  
pp. 616-621 ◽  
Author(s):  
Záviš Holzbecher

It has been found that phosphoric acid decreases the first excitation maximum of Ce(III) at 256 nm, increases the second excitation maximum at 297 nm and shifts the fluorescence maximum from 350 to 346 nm. Under optimum conditions, with λexc = 297 nm and λem = 346 nm, Ce(III) can be determined fluorimetrically with a detection limit of 1.2 ng ml-1 in 12M-H3PO4 medium. No interference was observed from a 20-200 fold excess of HCl, H2SO4, Na, K, NH4+, Al and the rare earth elements. HNO3 interferes and Ce(IV) and Fe(III) interfere strongly. It follows from the stereofluorograms of Ce and Tb that the spectra of the two elements are practically independent. The detection limit for Tb(III) in 0.02-2.5M-H2SO4 medium for λexc = 222 nm and λem = 494 nm is 33 ng ml-1. No interference was observed from a 5-20 fold excess of Al3+ and the other rare earth elements. The determination is slightly less sensitive in H3PO4 or HCl medium. The relative standard deviation of the measurement for 10 ng ml-1 Ce(III) or 50 ng ml-1 Tb(III) is about 3%.


Sign in / Sign up

Export Citation Format

Share Document