The enhanced coronal green line intensity and the magnetic field gradients

2000 ◽  
Vol 21 (3-4) ◽  
pp. 419-420
Author(s):  
K. B. Ramesh ◽  
B. S. Nagabhushana ◽  
B. A. Varghese
2000 ◽  
Vol 179 ◽  
pp. 419-420
Author(s):  
K. B. Ramesh ◽  
B. S. Nagabhushana ◽  
B. A. Varghese

Extended abstractRamesh, Nagabhushana and Varghese (1999) have shown that the green line intensity enhancement does not depend entirely on the strength of the underlying spot magnetic field though the coronal intensity enhanced feature is almost sure to occur at the locations of sunspots with strong magnetic fields and at the locations of plages having larger areas. Presented here are the results of an analysis of intensity of green line emission and the active region magnetic signatures as seen in Stanford magnetograms.The data base used in this study consisted of homogeneous data set (HDS) of 5303 Å green coronal intensity measured at position angle intervals of 5° on any given day from several stations (see Rybanský, 1975) and brought down to the common scale of Lomnicky Štit. Daily maps of sunspots, and Ca plages are then superposed on the green line intensity maps of the corresponding day. Resultant composite maps are then compared with the Stanford magnetograms published inSolar Geophysical Data.


1973 ◽  
Vol 10 (2) ◽  
pp. 249-263 ◽  
Author(s):  
B. Butt ◽  
G. S. Lakhina

Electromagnetic waves propagating perpendicular to an external magnetic field in a non-uniform anisotropic plasma can become unstable due to the excitation of either resonant ion instability or resonant electron instability. The former instability can exist in the absence of both the temperture anisotropy and the temperature gradients, whereas for the excitation of resonant electron instability the presence of at least one of them is necessary. An off-resonance drift cyclotron instability can also get excited if the temperature gradients are much stronger than the magnetic field gradients.


2016 ◽  
Vol 09 (01) ◽  
pp. 1650003 ◽  
Author(s):  
Pengfei Gao ◽  
Tie Liu ◽  
Meng Dong ◽  
Yi Yuan ◽  
Kai Wang ◽  
...  

We investigated how high magnetic field gradients affected the magnetostrictive performance of Tb[Formula: see text]Dy[Formula: see text]Fe[Formula: see text] during solidification. At high applied magnetic field gradients, the magnetostriction exhibited a gradient distribution throughout the alloy. Increasing the magnetic field gradient also increased the magnetostriction gradient. We attributed the graded magnetostrictive performance to the gradient distribution of (Tb, Dy)Fe2 phase in the alloy and its orientation.


Author(s):  
Alexandru Mihail Morega ◽  
Cristina Savastru ◽  
Mihaela Morega

Magnetic drug targeting (MDT) therapy is usually controlled through the magnetic field produced by a permanent magnet; the solution proposed and assessed here considers a planar spiral coil (PSC) or a system of such coils, as an equally effective magnetic field source. The PSC may be designed to provide proper configurations of the magnetic field gradients, required for the generation of high magnetic body forces and to limit, in the same time, unwanted side effects affecting adjacent tissue (heating, excitable tissue stimulation). Simplified numerical models (2D projections) and more realistic structures (3D representations) are shown and analyzed in the paper; the electromagnetic and heat transfer problems are solved for different powering schemes applied to the coils.


2008 ◽  
Vol 26 (1) ◽  
pp. 145-157 ◽  
Author(s):  
H. Nilsson ◽  
M. Waara ◽  
O. Marghitu ◽  
M. Yamauchi ◽  
R. Lundin ◽  
...  

Abstract. The role of the centrifugal acceleration mechanism for ion outflow at high altitude above the polar cap has been investigated. Magnetometer data from the four Cluster spacecraft has been used to obtain an estimate of magnetic field gradients. This is combined with ion moment data of the convection drift and the field-aligned particle velocity. Thus all spatial terms in the expression for the centrifugal acceleration are directly obtained from observations. The temporal variation of the unit vector of the magnetic field is estimated by predicting consecutive measurement-points through the use of observed estimates of the magnetic field gradients, and subtracting this from the consecutively observed value. The calculation has been performed for observations of outflowing O+ beams in January to May for the years 2001–2003, and covers an altitude range of about 5 to 12 RE. The accumulated centrifugal acceleration during each orbit is compared with the observed parallel velocities to get an estimate of the relative role of the centrifugal acceleration. Finally the observed spatial terms (parallel and perpendicular) of the centrifugal acceleration are compared with the results obtained when the magnetic field data was taken from the Tsyganenko T89 model instead. It is found that the centrifugal acceleration mechanism is significant, and may explain a large fraction of the parallel velocities observed at high altitude above the polar cap. The magnetic field model results underestimate the centrifugal acceleration at the highest altitudes investigated and show some systematic differences as compared to the observations in the lower altitude ranges investigated. Our results indicate that for altitudes corresponding to magnetic field values of more than 50 nT a test particle model with a steady state magnetic field model, a realistic convection model and an initial velocity of about 20 k m s−1 at 5 RE should be able to reproduce the main part of our observational results.


2019 ◽  
Vol 625 ◽  
pp. A129 ◽  
Author(s):  
C. J. Díaz Baso ◽  
M. J. Martínez González ◽  
A. Asensio Ramos

Aims. Our aim is to demonstrate the limitations of using a single-component model to study the magnetic field of an active region filament. To do this, we analyzed the polarimetric signals of the He I 10830 Å multiplet, which were acquired with the infrared spectrograph GRIS of the GREGOR telescope (Tenerife, Spain). Methods. After a first analysis of the general properties of the filament using HAZEL under the assumption of a single-component model atmosphere, in this second part we focus our attention on the observed Stokes profiles and the signatures that cannot be explained with this model. Results. We have found an optically thick filament whose blue and red components have the same sign in the linear polarization as an indication of radiative transfer effects. Moreover, the circular polarization signals inside the filament show strong magnetic field gradients. We also show that even a filament with such high absorption still shows signatures of the circular polarization that is generated by the magnetic field below the filament. The reason is that the absorption of the spectral line decays very quickly toward the wings, just where the circular polarization has a larger amplitude. In order to separate the two contributions, we explore the possibility of a two-component model, but the inference becomes impossible to overcome because very many solutions are compatible with the observations.


Author(s):  
Paul C. Lauterbur

Nuclear magnetic resonance imaging can reach microscopic resolution, as was noted many years ago, but the first serious attempt to explore the limits of the possibilities was made by Hedges. Resolution is ultimately limited under most circumstances by the signal-to-noise ratio, which is greater for small radio receiver coils, high magnetic fields and long observation times. The strongest signals in biological applications are obtained from water protons; for the usual magnetic fields used in NMR experiments (2-14 tesla), receiver coils of one to several millimeters in diameter, and observation times of a number of minutes, the volume resolution will be limited to a few hundred or thousand cubic micrometers. The proportions of voxels may be freely chosen within wide limits by varying the details of the imaging procedure. For isotropic resolution, therefore, objects of the order of (10μm) may be distinguished.Because the spatial coordinates are encoded by magnetic field gradients, the NMR resonance frequency differences, which determine the potential spatial resolution, may be made very large. As noted above, however, the corresponding volumes may become too small to give useful signal-to-noise ratios. In the presence of magnetic field gradients there will also be a loss of signal strength and resolution because molecular diffusion causes the coherence of the NMR signal to decay more rapidly than it otherwise would. This phenomenon is especially important in microscopic imaging.


2002 ◽  
Vol 20 (7) ◽  
pp. 567-573 ◽  
Author(s):  
Nikolaus Nestle ◽  
Asal Qadan ◽  
Petrik Galvosas ◽  
Wolfgang Süss ◽  
Jörg Kärger

Sign in / Sign up

Export Citation Format

Share Document