Abstract
A case of filamentous activated sludge bulking was investigated at an extended aeration plant treating wastes from a highway service centre. The purpose of the study was to find an effective control measure for the bulking and, if possible, to determine the cause of the bulking condition. Experiments were conducted to determine the effects upon bulking of: (a) a controlled copper dosage to the mixed liquor, (b) variations in the organic loading rate, and (c) maintenance of high and low dissolved oxygen concentrations in the mixed liquor.
The microorganism responsible for the bulking condition was tentatively identified as Sphaerotilus natans. Extensive growths of these bacteria occurred in the sludge when the mixed liquor dissolved oxygen concentration dropped below 0.5 mg/1. Such dissolved oxygen levels had frequently occurred at this plant due to the use of timed aeration cycles and the use of insufficient air supply during peak loading periods. Variations in organic loading rates were found to have no adverse effect on sludge settleability.
When bulking was slight, the condition could be improved by increasing the dissolved oxygen level to 1.5 mg/1, or more. The rate at which the filamentous growths could be eliminated from a highly filamentous sludge by increased aeration was very slow, but could be greatly increased by the simultaneous feeding of copper to the mixed liquor at a dosage rate of 1.0 mg/1, based on the raw sewage flows.