scholarly journals Results of an interlaboratory method performance study for the size determination and quantification of silver nanoparticles in chicken meat by single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS)

2017 ◽  
Vol 409 (20) ◽  
pp. 4839-4848 ◽  
Author(s):  
Stefan Weigel ◽  
Ruud Peters ◽  
Katrin Loeschner ◽  
Ringo Grombe ◽  
Thomas P. J. Linsinger
2016 ◽  
Vol 31 (7) ◽  
pp. 1430-1439 ◽  
Author(s):  
Claudio Toncelli ◽  
Kyriaki Mylona ◽  
Manolis Tsapakis ◽  
Spiros A. Pergantis

Description of a flow injection method for monitoring silver nanoparticles by single particle ICP-MS in seawater matrix and seawater microorganisms.


2007 ◽  
Vol 90 (3) ◽  
pp. 844-856 ◽  
Author(s):  
Kaare Julshamn ◽  
Amund Maage ◽  
Hilde Skaar Norli ◽  
Karl H Grobecker ◽  
Lars Jorhem ◽  
...  

Abstract Thirteen laboratories participated in an interlaboratory method performance (collaborative) study on a method for the determination of arsenic, cadmium, mercury, and lead by inductively coupled plasma/mass spectrometry (ICP/MS) after pressure digestion including the microwave heating technique. Prior to the study, the laboratories were able to practice on samples with defined element levels (pretrial test). The method was tested on a total of 7 foodstuffs: carrot puree, fish muscle, mushroom, graham flour, simulated diet, scampi, and mussel powder. The elemental concentrations in mg/kg dry matter (dm) ranged from 0.0621.4 for As, 0.0328.3 for Cd, 0.040.6 for Hg, and 0.012.4 for Pb. The materials used in the study were presented to the participants as blind duplicates, and the participants were asked to perform single determinations on each sample. The repeatability relative standard deviations (RSDr) for As ranged from 3.8 to 24%, for Cd from 2.6 to 6.9%, for Hg from 4.8 to 8.3%, and for Pb from 2.9 to 27%. The reproducibility relative standard deviations (RSDR) for As ranged from 9.0 to 28%, for Cd from 2.8 to 18%, for Hg from 9.9 to 24%, and for Pb from 8.0 to 50%. The HorRat values were less than 1.5 for all test samples, except for the determination of Pb in wheat flour at a level close to the limit of quantitation (0.01 mg/kg dm). The study showed that the ICP/MS method is satisfactory as a standard method for elemental determinations in foodstuffs.


Metallomics ◽  
2020 ◽  
Vol 12 (3) ◽  
pp. 408-415 ◽  
Author(s):  
Joanna Kruszewska ◽  
Dominika Kulpińska ◽  
Ilona Grabowska-Jadach ◽  
Magdalena Matczuk

ICP-MS-based platform for the characterization of medicinally attractive nanomaterials processing inside human cells.


Sign in / Sign up

Export Citation Format

Share Document