Evaluation of cerebral arteriovenous shunts: a comparison of parallel imaging time-of-flight magnetic resonance angiography (TOF-MRA) and compressed sensing TOF-MRA to digital subtraction angiography

2020 ◽  
Author(s):  
Akihiko Sakata ◽  
Yasutaka Fushimi ◽  
Tomohisa Okada ◽  
Satoshi Nakajima ◽  
Takuya Hinoda ◽  
...  
2021 ◽  
pp. 197140092098809
Author(s):  
Donghyun Kim ◽  
Young Jin Heo ◽  
Hae Woong Jeong ◽  
Jin Wook Baek ◽  
Gi Won Shin ◽  
...  

Background and purpose Compressed sensing is used for accelerated acquisitions with incoherently under-sampled k-space data, and intracranial time-of-flight magnetic resonance angiography is suitable for compressed sensing. Compressed sensing time-of-flight is beneficial in decreasing acquisition time and increasing spatial resolution while maintaining acquisition time. In this retrospective study, we aimed to evaluate the image quality and diagnostic performance of compressed sensing time-of-flight with high spatial resolution and compare with parallel imaging time-of-flight using digital subtraction angiography as a reference. Material and methods In total, 39 patients with 46 intracranial aneurysms underwent parallel imaging and compressed sensing time-of-flight in the same imaging session and digital subtraction angiography before or after magnetic resonance angiography. The overall image quality, artefacts and diagnostic confidence were assessed by two observers. The contrast ratio, maximal aneurysm diameters and diagnostic performance were evaluated. Results Compressed sensing time-of-flight showed significantly better overall image quality, degree of artefacts and diagnostic confidence in both observers, with better inter-observer agreement. The contrast ratio was significantly higher for compressed sensing time-of-flight than for parallel imaging time-of-flight in both observers (source images, P < 0.001; maximum intensity projection images, P < 0.05 for both observers); however, the measured maximal diameters of aneurysms were not significantly different. Compressed sensing time-of-flight showed higher sensitivity, specificity, accuracy and positive and negative predictive values for detecting aneurysms than parallel imaging time-of-flight in both observers, with better inter-observer agreement. Compressed sensing time-of-flight was preferred over parallel imaging time-of-flight by both observers; however, parallel imaging time-of-flight was preferred in cases of giant and large aneurysms. Conclusions Compressed sensing-time-of-flight provides better image quality and diagnostic performance than parallel imaging time-of-flight. However, neuroradiologists should be aware of under-sampling artefacts caused by compressed sensing.


2021 ◽  
pp. 197140092110217
Author(s):  
Miho Gomyo ◽  
Kazuhiro Tsuchiya ◽  
Shun Goto ◽  
Shinsuke Hosoi ◽  
Takahiro Tahara ◽  
...  

Purpose After stent-assisted treatment for intracranial diseases, three-dimensional time-of-flight magnetic resonance angiography is a noninvasive follow-up method, but susceptibility artifacts prevent accurate evaluations of stented arteries. Sampling perfection with application-optimized contrast using different flip angle evolution (SPACE) sequence often used for vessel wall imaging is less susceptible to susceptibility artifacts, since it is a spin-echo sequence. Hence, we evaluated the feasibility of black-blood magnetic resonance angiography generated from vessel wall imaging data obtained using the SPACE sequence in the depiction of stented arteries by comparing with three-dimensional time-of-flight magnetic resonance angiography and digital subtraction angiography. Methods Our study group comprised 11 consecutive patients. For both three-dimensional time-of-flight magnetic resonance angiography and black-blood magnetic resonance angiography, the contrast ratio obtained from the stented artery and the normal artery proximal to the stent were calculated. And the depiction of stented arteries was visually evaluated. Additionally, the relative diameter index obtained from the stented artery and the normal artery proximal to the stent were calculated for three-dimensional time-of-flight magnetic resonance angiography, black-blood magnetic resonance angiography and digital subtraction angiography. Results The contrast ratio of the stented artery was significantly lower than that of the normal artery on three-dimensional time-of-flight magnetic resonance angiography, but no significant difference was seen using black-blood magnetic resonance angiography. Regarding both the diameter index and the visual assessment score, black-blood magnetic resonance angiography was significantly better than three-dimensional time-of-flight magnetic resonance angiography. On black-blood magnetic resonance angiography, the diameter index was equal to that of digital subtraction angiography, and the flow signal was homogeneous and continuous in most the cases.


2021 ◽  
Vol 84 (2) ◽  
pp. 119-123
Author(s):  
Mami Ishikawa ◽  
Satoshi Terao ◽  
Hiroshi Kagami ◽  
Makoto Inaba ◽  
Heiji Naritaka

<b><i>Background:</i></b> Patients with moyamoya disease often develop cerebral infarction and hemorrhage, but the ischemic and hemorrhagic subtypes are difficult to diagnose prior to disease onset. We aimed to differentiate the ischemic and hemorrhagic subtypes of moyamoya disease by analyzing the intralateral and perilateral ventricular arteries on the original axial magnetic resonance angiography (MRA) images. <b><i>Methods:</i></b> We retrospectively analyzed the intralateral and perilateral ventricular arteries on the original axial time-of-flight (TOF)-MRA images of 18 patients with hemorrhagic moyamoya disease, 25 patients with ischemic moyamoya disease, and 22 control patients with unruptured aneurysms. <b><i>Results:</i></b> There were significantly more intralateral and perilateral ventricular arteries on the original axial MRA images in the patients with hemorrhagic moyamoya disease (6.3 ± 2.7) than in those with ischemic moyamoya disease (0.8 ± 0.9) and those with unruptured aneurysms (0.4 ± 0.8). <b><i>Conclusion:</i></b> The intralateral and perilateral ventricular arteries on the original axial TOF-MRA images might suggest the hemorrhagic type of moyamoya disease prior to onset.


Sign in / Sign up

Export Citation Format

Share Document