scholarly journals Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis

2019 ◽  
Vol 30 (4) ◽  
pp. 1876-1884
Author(s):  
He An ◽  
Xiaodong Ma ◽  
Ziyi Pan ◽  
Hua Guo ◽  
Elaine Yuen Phin Lee

Abstract Objectives To qualitatively and quantitatively compare the image quality between single-shot echo-planar (SS-EPI) and multi-shot echo-planar (IMS-EPI) diffusion-weighted imaging (DWI) in female pelvis Methods This was a prospective study involving 80 females who underwent 3.0T pelvic magnetic resonance imaging (MRI). SS-EPI and IMS-EPI DWI were acquired with 3 b values (0, 400, 800 s/mm2). Two independent reviewers assessed the overall image quality, artifacts, sharpness, and lesion conspicuity based on a 5-point Likert scale. Regions of interest (ROI) were placed on the endometrium and the gluteus muscles to quantify the signal intensities and apparent diffusion coefficient (ADC). Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and geometric distortion were quantified on both sequences. Inter-rater agreement was assessed using κ statistics and Kendall test. Qualitative scores were compared using Wilcoxon signed-rank test and quantitative parameters were compared with paired t test and Bland-Altman analysis. Results IMS-EPI demonstrated better image quality than SS-EPI for all aspects evaluated (SS-EPI vs. IMS-EPI: overall quality 3.04 vs. 4.17, artifacts 3.09 vs. 3.99, sharpness 2.40 vs. 4.32, lesion conspicuity 3.20 vs. 4.25; p < 0.001). Good agreement and correlation were observed between two reviewers (SS-EPI κ 0.699, r 0.742; IMS-EPI κ 0.702, r 0.789). IMS-EPI showed lower geometric distortion, SNR, and CNR than SS-EPI (p < 0.050). There was no significant difference in the mean ADC between the two sequences. Conclusion IMS-EPI showed better image quality with lower geometric distortion without affecting the quantification of ADC, though the SNR and CNR decreased due to post-processing limitations. Key Points • IMS-EPI showed better image quality than SS-EPI. • IMS-EPI showed lower geometric distortion without affecting ADC compared with SS-EPI. • The SNR and CNR of IMS-EPI decreased due to post-processing limitations.

2021 ◽  
Vol 10 (2) ◽  
pp. 205846012199473
Author(s):  
Takeshi Yoshizako ◽  
Rika Yoshida ◽  
Hiroya Asou ◽  
Megumi Nakamura ◽  
Hajime Kitagaki

Background Echo-planar imaging (EPI)-diffusion-weighted imaging (DWI) may take unclear image affected by susceptibility, geometric distortions and chemical shift artifacts. Purpose To compare the image quality and usefulness of EPI-DWI and turbo spin echo (TSE)-DWI in female patients who required imaging of the pelvis. Material and Methods All 57 patients were examined with a 3.0-T MR scanner. Both TSE- and EPI-DWI were performed with b values of 0 and 1000 s/mm2. We compared geometric distortion, the contrast ratio (CR) of the myometrium to the muscle and the apparent diffusion coefficient (ADC) values for the myometrium and lesion. Two radiologists scored the TSE- and EPI-DWI of each patient for qualitative evaluation. Results The mean percent distortion was significantly smaller with TSE- than EPI-DWI ( p = 0.00). The CR was significantly higher with TSE- than EPI-DWI ( p = 0.003). There was a significant difference in the ADC value for the uterus and lesions between the EPI- and TSE-DWI ( p < 0.05). Finally, the ADC values of cancer were significantly different from those for the uterus and benign with both the two sequences ( p < 0.05). The scores for ghosting artifacts were higher with TSE- than EPI-DWI ( p = 0.019). But there were no significant differences between TSE- and EPI-DWI with regard to image contrast and overall image quality. Conclusion TSE-DWI on the female pelvis by 3T MRI produces less distortion and higher CR than EPI-DWI, but there is no difference in contrast and image quality.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Mengnv Xie ◽  
Zhen Ren ◽  
Dujun Bian ◽  
Dan Li ◽  
Li Yu ◽  
...  

Abstract Background We assessed the image quality of endometrial cancer lesions by readout segmentation of long variable echo-trains (RESOLVE) diffusion-weighted imaging (DWI) compared with that by single-shot echo-planar imaging (SS-EPI) DWI, aimed to explore the value of RESOLVE DWI for determining myometrial invasion and clinical stage in endometrial cancer. Materials and methods From April 2017 to March 2018, a total of 30 endometrial cancer patients (mean age 52.8 ± 9.0 years), who had undergone RESOLVE DWI and SS-EPI DWI, were included in the study. The image quality of endometrial carcinoma by two kinds of DWI scanning methods was compared qualitatively and quantitatively. The Spearman rank correlation test was used to assess the correlation of qualitative image quality scores between two readers. The accuracy of two DWI methods in detecting myometrial invasion and staging of endometrial carcinoma was calculated according to postoperative pathological results. The indexes were analyzed including sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV). Results The qualitative score of RESOLVE DWI group was superior to SS-EPI DWI group in every aspect of five aspects (all P < 0.001). Interobserver agreement of depiction was good or excellent in two DWI sequences. Signal to noise ratio and contrast to noise ratio values in RESOLVE DWI group were both higher than those in SS-EPI DWI group (P<0.001). No statistical difference of apparent diffusion coefficient value was observed between two DWI groups (P = 0.261). The specificity, accuracy, PPV, and NPV of estimating myometrial invasion by RESOLVE DWI in three cases (intramucosal lesion, <50% superficial invasion and ≥ 50% deep invasion) were all higher than those by SS-EPI DWI for endometrial carcinoma. Especially RESOLVE DWI was valuable in judging <50% superficial invasion (95%CI:0.586, 0.970). No significant difference in accuracy staging was between the two DWI groups (P = 0.125). Conclusion RESOLVE DWI can provide higher quality images of endometrial carcinoma than SS-EPI DWI. The high-quality images are helpful for precise assessment of myometrial invasion in endometrial cancer.


2014 ◽  
Vol 40 (1) ◽  
pp. 120-126 ◽  
Author(s):  
Andrew B. Rosenkrantz ◽  
Hersh Chandarana ◽  
Josef Pfeuffer ◽  
Michael J. Triolo ◽  
Mohammed Bilal Shaikh ◽  
...  

2017 ◽  
Vol 58 (12) ◽  
pp. 1457-1467 ◽  
Author(s):  
Xiaoquan Xu ◽  
Yanjun Wang ◽  
Hao Hu ◽  
Guoyi Su ◽  
Hu Liu ◽  
...  

Background Readout-segmented echo-planar imaging (RS-EPI) could improve the imaging quality of diffusion-weighted imaging (DWI) in various organs. However, whether it could improve the imaging quality and diagnostic performance for the patients with orbital tumors is still unknown. Purpose To compare the image quality and diagnostic performance of RS-EPI DWI with that of conventional single-shot EPI (SS-EPI) DWI in patients with orbital tumors. Material and Methods SS-EPI and RS-EPI DW images of 32 patients with pathologically diagnosed orbital tumors were retrospectively analyzed. Qualitative imaging parameters (imaging sharpness, geometric distortion, ghosting artifacts, and overall imaging quality) and quantitative imaging parameters (apparent diffusion coefficient [ADC], signal-to-noise ratio [SNR], contrast, and contrast-to-noise ratio [CNR]) were assessed by two independent radiologists, and compared between SS-EPI and RS-EPI DWI. Receiver operating characteristic curves were used to determine the diagnostic value of ADC in differentiating malignant from benign orbital tumors. Results RS-EPI DW imaging produced less geometric distortion and ghosting artifacts, and better imaging sharpness and overall imaging quality than SS-EPI DWI (for all, P < 0.001). Meanwhile, RS-EPI DWI produced significantly lower SNR ( P < 0.001) and ADC ( P < 0.001), and higher contrast ( P < 0.001) than SS-EPI DWI, while producing no difference in CNR ( P = 0.137). There was no significant difference on the diagnostic performance between SS-EPI and RS-EPI DWI, when using ADC as the differentiating index ( P = 0.529). Conclusion Compared with SS-EPI, RS-EPI DWI provided significantly better imaging quality and comparable diagnostic performance in differentiating malignant from benign orbital tumors.


2020 ◽  
Author(s):  
Jia-Suo Jiang ◽  
Liu-Ning Zhu ◽  
Qian Wu ◽  
Yi Sun ◽  
Wei Liu ◽  
...  

Abstract Background To evaluate the feasibility of using simultaneous multi-slice (SMS) readout segmentation of long variable echo-trains (RESOLVE) diffusion-weighted imaging (DWI) to assess parotid gland tumors, compared with conventional RESOLVE DWI Methods From September 2018 to December 2018, 20 consecutive patients with parotid tumors who underwent MRI scan for pre-surgery evaluation were enrolled. SMS-RESOLVE DWI and conventional RESOLVE DWI were scanned with matched imaging parameters, respectively. The scan time of two DWI sequences was recorded. Qualitative (anatomical structure differentiation, lesion display, artifact, and overall image quality) and quantitative (apparent diffusion coefficient, ADC; ratio of signal-to-noise ratio, SNR ratio; ratio of contrast-to-noise ratio, CNR ratio) assessments of image quality were performed, and compared between SMS-RESOLVE DWI and conventional RESOLVE DWI. Paired t-test was used for statistical analyses. Results The scan time was 3 minutes and 41 seconds for SMS-RESOLVE DWI, and 5 minutes and 46 seconds for conventional RESOLVE DWI. SMS-RESOLVE DWI produced similar qualitative image quality with RESOLVE DWI (anatomical structure differentiation, P = 0.164; lesion display, P = 0.193; artifact, P = 0.330; overall image quality, P = 0.083). Meanwhile, there were no significant difference on ADCLesion (P = 0.298), ADCMasseter (P = 0.122), SNR ratio (P = 0.584) and CNR ratio (P = 0.217) between two DWI sequences. Conclusion Compared with conventional RESOLVE DWI, SMS-RESOLVE DWI could provide comparable image quality using markedly reduced scan time. SMS could increase the clinical usability of RESOLVE technique for DWI of parotid gland.


Sign in / Sign up

Export Citation Format