echo planar imaging
Recently Published Documents


TOTAL DOCUMENTS

616
(FIVE YEARS 80)

H-INDEX

63
(FIVE YEARS 5)

Author(s):  
Jos J. M. Westenberg ◽  
Hans C. Assen ◽  
Pieter J. den Boogaard ◽  
Jelle J. Goeman ◽  
Hicham Saaid ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 2273
Author(s):  
Shuyi Peng ◽  
Yihao Guo ◽  
Xiaoyong Zhang ◽  
Juan Tao ◽  
Jie Liu ◽  
...  

To investigate the feasibility and effectiveness of high-resolution readout-segmented echo planar imaging (rs-EPI), diffusion-weighted imaging (DWI) is used simultaneously with multi-slice (SMS) imaging (SMS rs-EPI) for the differentiation of breast malignant and benign lesions in comparison to conventional rs-EPI on a 3T MR scanner. A total of 102 patients with 113 breast lesions underwent bilateral breast MRI using a prototype SMS rs-EPI sequence and a conventional rs-EPI sequence. Subjective image quality was assessed using a 5-point Likert scale (1 = poor, 5 = excellent). Signal-to-noise ratio (SNR), lesion contrast-to-noise ratio (CNR) and apparent diffusion coefficients (ADC) value of the lesion were measured for comparison. Receiver operating characteristic curve analysis was performed to evaluate the diagnosis performance of ADC, and the corresponding area under curve (AUC) was calculated. The image quality scores in anatomic distortion, lesion conspicuity, sharpness of anatomical details and overall image quality of SMS rs-EPI were significantly higher than those of conventional rs-EPI. CNR was enhanced in the high-resolution SMS rs-EPI acquisition (6.48 ± 1.71 vs. 4.23 ± 1.49; p < 0.001). The mean ADC value was comparable in SMS rs-EPI and conventional rs-EPI (benign 1.45 × 10−3 vs. 1.43 × 10−3 mm2/s, p = 0.702; malignant 0.91 × 10−3 vs. 0.89 × 10−3 mm2/s, p = 0.076). The AUC was 0.957 in SMS rs-EPI and 0.983 in conventional rs-EPI. SMS rs-EPI technique allows for higher spatial resolution and slight reduction of scan time in comparison to conventional rs-EPI, which has potential for better differentiation between malignant and benign lesions of the breast.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Po-Wei Cheng ◽  
Tzi-Dar Chiueh ◽  
Jyh-Horng Chen

AbstractLatest simultaneous multi-slice (SMS) methods greatly benefit MR efficiency for recent studies using parallel imaging technique. However, these methods are limited by the requirement of array coils. The proposed Coherent Wideband method, which employs an extended field of view to separate multiple excited slices, can be applied to any existing MRI instrument, even those without array coils. In this study, the Coherent Wideband echo-planar imaging method was implemented on 7 T animal MRI to exhibit comprehensive enhancements in neuro-architecture, including diffusion tensor imaging (DTI) and functional MR studies (fMRI). Under the same scan time, the time-saving effect can be manipulated to increase the number of averages for DTI SNR improvement, reducing fractional anisotropy difference by 56.9% (from 0.072 to 0.041) and the deviation angle by 64% (from 25.3° to 16.2°). In summary, Coherent Wideband Echo Planar Imaging (EPI) will provide faster, higher resolution, thinner slice, or higher SNR imaging for precision neuro-architecture studies.


Author(s):  
Christoph A. Rettenmeier ◽  
Danilo Maziero ◽  
V. Andrew Stenger

Sign in / Sign up

Export Citation Format

Share Document