scholarly journals Assessment of thoracic disk herniation by using virtual noncalcium dual-energy CT in comparison with standard grayscale CT

Author(s):  
Vitali Koch ◽  
Ibrahim Yel ◽  
Leon D. Grünewald ◽  
Sebastian Beckers ◽  
Iris Burck ◽  
...  

Abstract Objectives To determine the diagnostic accuracy of dual-energy CT (DECT) virtual noncalcium (VNCa) reconstructions for assessing thoracic disk herniation compared to standard grayscale CT. Methods In this retrospective study, 87 patients (1131 intervertebral disks; mean age, 66 years; 47 women) who underwent third-generation dual-source DECT and 3.0-T MRI within 3 weeks between November 2016 and April 2020 were included. Five blinded radiologists analyzed standard DECT and color-coded VNCa images after a time interval of 8 weeks for the presence and degree of thoracic disk herniation and spinal nerve root impingement. Consensus reading of independently evaluated MRI series served as the reference standard, assessed by two separate experienced readers. Additionally, image ratings were carried out by using 5-point Likert scales. Results MRI revealed a total of 133 herniated thoracic disks. Color-coded VNCa images yielded higher overall sensitivity (624/665 [94%; 95% CI, 0.89–0.96] vs 485/665 [73%; 95% CI, 0.67–0.80]), specificity (4775/4990 [96%; 95% CI, 0.90–0.98] vs 4066/4990 [82%; 95% CI, 0.79–0.84]), and accuracy (5399/5655 [96%; 95% CI, 0.93–0.98] vs 4551/5655 [81%; 95% CI, 0.74–0.86]) for the assessment of thoracic disk herniation compared to standard CT (all p < .001). Interrater agreement was excellent for VNCa and fair for standard CT (ϰ = 0.82 vs 0.37; p < .001). In addition, VNCa imaging achieved higher scores regarding diagnostic confidence, image quality, and noise compared to standard CT (all p < .001). Conclusions Color-coded VNCa imaging yielded substantially higher diagnostic accuracy and confidence for assessing thoracic disk herniation compared to standard CT. Key Points • Color-coded VNCa reconstructions derived from third-generation dual-source dual-energy CT yielded significantly higher diagnostic accuracy for the assessment of thoracic disk herniation and spinal nerve root impingement compared to standard grayscale CT. • VNCa imaging provided higher diagnostic confidence and image quality at lower noise levels compared to standard grayscale CT. • Color-coded VNCa images may potentially serve as a viable imaging alternative to MRI under circumstances where MRI is unavailable or contraindicated.

2019 ◽  
Vol 124 (8) ◽  
pp. 745-752 ◽  
Author(s):  
Andrea Agostini ◽  
Alberto Mari ◽  
Cecilia Lanza ◽  
Nicolo’ Schicchi ◽  
Alessandra Borgheresi ◽  
...  

Author(s):  
Vitali Koch ◽  
Moritz H. Albrecht ◽  
Leon D. Gruenewald ◽  
Ibrahim Yel ◽  
Katrin Eichler ◽  
...  

Abstract Objectives To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging. Methods A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard. Results MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05). Conclusions Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations. Key Points • Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference. • Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series. • Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.


2019 ◽  
Vol 29 (9) ◽  
pp. 4603-4612 ◽  
Author(s):  
Lukas Lenga ◽  
Franziska Trapp ◽  
Moritz H. Albrecht ◽  
Julian L. Wichmann ◽  
Addison A. Johnson ◽  
...  

Author(s):  
Swathigha Selvaraj ◽  
Niyas N. P. ◽  
Rupa Renganathan ◽  
Rajkumar Ramasamy ◽  
Rinoy Ram Anandan ◽  
...  

Abstract Objectives The aims of our study were to assess the comparability of conventional unenhanced images (CUIs) of hepatopancreaticobiliary system with virtual unenhanced images (VUIs) derived from arterial and portal venous phases acquired in a third-generation, dual-source, dual-energy CT (DECT), and also to assess the best dataset among these VUIs. We also calculated the radiation effective dose (ED) reduction by eliminating noncontrast acquisition. Materials and Methods 60 patients were included in our study. Unenhanced images in single energy and contrast-enhanced images in dual-energy mode were acquired. Arterial virtual unenhanced (AVU) and portal virtual unenhanced (PVU) images were generated and compared with CUI, using both objective and subjective methods. The ED was calculated separately for each phase. Statistical significance between difference in mean attenuation values were analyzed using ANOVA and unpaired student t-test. Results In our study, the difference in mean attenuation of liver, spleen, and pancreas between the three phases—CU, AVU, and PVU—were insignificant with p-value > 0.05. This indicates that the values were comparable. Among the VUI, AVU images were statistically superior in image quality. Elimination of noncontrast CT from triple phase abdominal imaging can achieve an average ED reduction of 39%. Conclusions We conclude that VUI generated in third-generation, dual-source DECT has diagnostic image quality and can replace the CUI in triple-phase studies, with a mean ED reduction by 39%. The VUI obtained from arterial phase is superior to those obtained from portal venous phase.


2018 ◽  
Vol 37 (4) ◽  
pp. 735-741 ◽  
Author(s):  
Tim Nestler ◽  
Kai Nestler ◽  
Andreas Neisius ◽  
Hendrik Isbarn ◽  
Christopher Netsch ◽  
...  

Diagnostics ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 1072
Author(s):  
Moritz T. Winkelmann ◽  
Saif Afat ◽  
Sven S. Walter ◽  
Eva Stock ◽  
Vincent Schwarze ◽  
...  

The aim of this study was to investigate the effects of dose reduction on diagnostic accuracy and image quality of cervical computed tomography (CT) in patients with suspected cervical abscess. Forty-eight patients (mean age 45.5 years) received a CT for suspected cervical abscess. Low-dose CT (LDCT) datasets with 25%, 50%, and 75% of the original dose were generated with a realistic simulation. The image data were reconstructed with filtered back projection (FBP) and with advanced modeled iterative reconstruction (ADMIRE) (strengths 3 and 5). A five-point Likert scale was used to assess subjective image quality and diagnostic confidence. The signal-to-noise ratio (SNR) of the sternocleidomastoid muscle and submandibular gland and the contrast-to-noise ratio (CNR) of the sternocleidomastoid muscle and submandibular glandular fat were calculated to assess the objective image quality. Diagnostic accuracy was calculated for LDCT using the original dose as the reference standard. The prevalence of cervical abscesses was high (72.9%) in the cohort; the mean effective dose for all 48 scans was 1.8 ± 0.8 mSv. Sternocleidomastoid and submandibular SNR and sternocleidomastoid muscle fat and submandibular gland fat CNR increased with higher doses and were significantly higher for ADMIRE compared to FBP, with the best results in ADMIRE 5 (all p < 0.001). Subjective image quality was highest for ADMIRE 5 at 75% and lowest for FBP at 25% of the original dose (p < 0.001). Diagnostic confidence was highest for ADMIRE 5 at 75% and lowest for FBP at 25% (p < 0.001). Patient-based diagnostic accuracy was high for all LDCT datasets, down to 25% for ADMIRE 3 and 5 (sensitivity: 100%; specificity: 100%) and lower for FBP at 25% dose reduction (sensitivity: 88.6–94.3%; specificity: 92.3–100%). The use of a modern dual-source CT of the third generation and iterative reconstruction allows a reduction in the radiation dose to 25% (0.5 mSv) of the original dose with the same diagnostic accuracy for the assessment of neck abscesses.


Author(s):  
S. Sawall ◽  
L. Klein ◽  
E. Wehrse ◽  
L. T. Rotkopf ◽  
C. Amato ◽  
...  

Abstract Objective To evaluate the dual-energy (DE) performance and spectral separation with respect to iodine imaging in a photon-counting CT (PCCT) and compare it to dual-source CT (DSCT) DE imaging. Methods A semi-anthropomorphic phantom extendable with fat rings equipped with iodine vials is measured in an experimental PCCT. The system comprises a PC detector with two energy bins (20 keV, T) and (T, eU) with threshold T and tube voltage U. Measurements using the PCCT are performed at all available tube voltages (80 to 140 kV) and threshold settings (50–90 keV). Further measurements are performed using a conventional energy-integrating DSCT. Spectral separation is quantified as the relative contrast media ratio R between the energy bins and low/high images. Image noise and dose-normalized contrast-to-noise ratio (CNRD) are evaluated in resulting iodine images. All results are validated in a post-mortem angiography study. Results R of the PC detector varies between 1.2 and 2.6 and increases with higher thresholds and higher tube voltage. Reference R of the EI DSCT is found as 2.20 on average overall phantoms. Maximum CNRD in iodine images is found for T = 60/65/70/70 keV for 80/100/120/140 kV. The highest CNRD of the PCCT is obtained using 140 kV and is decreasing with decreasing tube voltage. All results could be confirmed in the post-mortem angiography study. Conclusion Intrinsically acquired DE data are able to provide iodine images similar to conventional DSCT. However, PCCT thresholds should be chosen with respect to tube voltage to maximize image quality in retrospectively derived image sets. Key Points • Photon-counting CT allows for the computation of iodine images with similar quality compared to conventional dual-source dual-energy CT. • Thresholds should be chosen as a function of the tube voltage to maximize iodine contrast-to-noise ratio in derived image sets. • Image quality of retrospectively computed image sets can be maximized using optimized threshold settings.


Sign in / Sign up

Export Citation Format

Share Document