Three-dimensional laser absorption spectroscopy velocimetry for high-speed flow diagnosis

2019 ◽  
Vol 125 (7) ◽  
Author(s):  
Qianwei Qu ◽  
Shuo Gao ◽  
Liuyong Chang ◽  
Lijun Xu
Author(s):  
Maximilian Passmann ◽  
Stefan aus der Wiesche ◽  
Eugeny Y. Kenig

Abstract Low speed and high speed flow phenomena in pillow plate channels are considered. High speed flows were investigated by means of analytical methods and fully three-dimensional computational fluid dynamics (CFD) simulations. The theoretical analysis indicated that a Fanno-type flow model described high speed flow behavior in pillow plate channels reasonably well. Since only wavy walls with smooth profiles were involved, linearized gas dynamics was applied in order to derive similarity laws for the high speed flows. The detailed CFD analysis was used to support the assumption of a Fanno-type flow. The effects of the wavy wall structures on pressure drop and Mach number distribution within the flow path were investigated in detail. The present analysis demonstrates that pillow plate heat exchangers represent promising candidates for high speed turbo machinery applications.


2021 ◽  
Vol 11 (8) ◽  
pp. 3701
Author(s):  
Sunghyun So ◽  
Nakwon Jeong ◽  
Aran Song ◽  
Jungho Hwang ◽  
Daehae Kim ◽  
...  

It is important to monitor the temperature and H2O concentration in a large combustion environment in order to improve combustion (and thermal) efficiency and reduce harmful combustion emissions. However, it is difficult to simultaneously measure both internal temperature and gas concentration in a large combustion system because of the harsh environment with rapid flow. In regard, tunable diode laser absorption spectroscopy, which has the advantages of non-intrusive, high-speed response, and in situ measurement, is highly attractive for measuring the concentration of a specific gas species in the combustion environment. In this study, two partially overlapped H2O absorption signals were used in the tunable diode laser absorption spectroscopy (TDLAS) to measure the temperature and H2O concentration in a premixed CH4/air flame due to the wide selection of wavelengths with high temperature sensitivity and advantages where high frequency modulation can be applied. The wavelength regions of the two partially overlapped H2O absorptions were 1.3492 and 1.34927 μm. The measured signals separated the multi-peak Voigt fitting. As a result, the temperature measured by TDLAS based on multi-peak Voigt fitting in the premixed CH4/air flame was the highest at 1385.80 K for an equivalence ratio of 1.00. It also showed a similarity to those tendencies to the temperature measured by the corrected R-type T/C. In addition, the H2O concentrations measured by TDLAS based on the total integrated absorbance area for various equivalent ratios were consistent with those calculated by the chemical equilibrium simulation. Additionally, the H2O concentration measured at an equivalence ratio of 1.15 was the highest at 18.92%.


Sign in / Sign up

Export Citation Format

Share Document