scholarly journals Prognostic value of electrocardiographic detection of unrecognized myocardial infarction in persons with stable coronary artery disease: data from the Heart and Soul Study

2010 ◽  
Vol 100 (4) ◽  
pp. 359-366 ◽  
Author(s):  
Devin W. Kehl ◽  
Ramin Farzaneh-Far ◽  
Beeya Na ◽  
Mary A. Whooley
2021 ◽  
Vol 49 (6) ◽  
pp. 030006052110196
Author(s):  
Heyu Meng ◽  
Jianjun Ruan ◽  
Xiaomin Tian ◽  
Lihong Li ◽  
Weiwei Chen ◽  
...  

Objective This study aimed to investigate whether differential expression of the retinoic acid receptor-related orphan receptor A ( RORA) gene is related to occurrence of acute myocardial infarction (AMI). Methods This was a retrospective study. White blood cells of 93 patients with acute myocardial infarction and 74 patients with stable coronary artery disease were collected. Reverse transcription quantitative polymerase chain reaction and western blotting were used to measure RORA mRNA and protein expression, respectively. Results RORA mRNA expression levels in peripheral blood leukocytes in patients with AMI were 1.57 times higher than those in patients with stable coronary artery disease. Protein RORA levels in peripheral blood of patients with AMI were increased. Binary logistic regression analysis showed that high expression of RORA was an independent risk factor for AMI, and it increased the risk of AMI by 2.990 times. Conclusion RORA expression levels in patients with AMI is significantly higher than that in patients with stable coronary artery disease. High expression of RORA is related to AMI and it may be an independent risk factor for AMI.


Author(s):  
Tomonori Itoh ◽  
◽  
Hiromasa Otake ◽  
Takumi Kimura ◽  
Yoshiro Tsukiyama ◽  
...  

AbstractThe purpose of this study was to assess early and late vascular healing in response to bioresorbable-polymer sirolimus-eluting stents (BP-SESs) for the treatment of patients with ST-elevation myocardial infarction (STEMI) and stable coronary artery disease (CAD). A total of 106 patients with STEMI and 101 patients with stable-CAD were enrolled. Optical frequency-domain images were acquired at baseline, at 1- or 3-month follow-up, and at 12-month follow-up. In the STEMI and CAD cohorts, the percentage of uncovered struts (%US) was significantly and remarkably decreased during early two points and at 12-month (the STEMI cohort: 1-month: 18.75 ± 0.78%, 3-month: 10.19 ± 0.77%, 12-month: 1.80 ± 0.72%; p < 0.001, the CAD cohort: 1-month: 9.44 ± 0.78%, 3-month: 7.78 ± 0.78%, 12-month: 1.07 ± 0.73%; p < 0.001 respectively). The average peri-strut low-intensity area (PLIA) score in the STEMI cohort was significantly decreased during follow-up period (1.90 ± 1.14, 1.18 ± 1.25, and 1.01 ± 0.72; p ≤ 0.001), whereas the one in the CAD cohort was not significantly changed (0.89 ± 1.24, 0.67 ± 1.07, and 0.64 ± 0.72; p = 0.59). In comparison with both groups, differences of %US and PLIA score at early two points were almost disappeared or close at 12 months. The strut-coverage and healing processes in the early phase after BP-SES implantation were significantly improved in both cohorts, especially markedly in STEMI patients. At 1 year, qualitatively and quantitatively consistent neointimal coverage was achieved in both pathogenetic groups.


Sign in / Sign up

Export Citation Format

Share Document