High throughput screening for spores and vegetative forms of pathogenic B. anthracis by an internally controlled real-time PCR assay with automated DNA preparation

2006 ◽  
Vol 196 (1) ◽  
pp. 41-50 ◽  
Author(s):  
Marcus Panning ◽  
Stefanie Kramme ◽  
Nadine Petersen ◽  
Christian Drosten
1999 ◽  
Vol 37 (6) ◽  
pp. 1941-1947 ◽  
Author(s):  
Alexander J. Ryncarz ◽  
James Goddard ◽  
Anna Wald ◽  
Meei-Li Huang ◽  
Bernard Roizman ◽  
...  

We have developed a high-throughput, semiautomated, quantitative fluorescence-based PCR assay to detect and type herpes simplex virus (HSV) DNA in clinical samples. The detection assay, which uses primers to the type-common region of HSV glycoprotein B (gB), was linear from <10 to 108 copies of HSV DNA/20 μl of sample. Among duplicate samples in reproducibility runs, the assay showed less than 5% variability. We compared the fluorescence-based PCR assay with culture and gel-based liquid hybridization system with 335 genital tract specimens from HSV type 2 (HSV-2)-seropositive persons attending a research clinic and 380 consecutive cerebrospinal fluid (CSF) samples submitted to a diagnostic virology laboratory. Among the 162 culture-positive genital tract specimens, TaqMan PCR was positive for 157 (97%) specimens, whereas the quantitative-competitive PCR was positive for 144 (89%) specimens. Comparisons of the mean titer of HSV DNA detected by the two assays revealed that the mean titer detected by the gel-based system was slightly higher (median, 1 log). These differences in titers were in part related to the fivefold difference in the amount of HSV DNA used in the amplicon standards with the two assays. Among the 380 CSF samples, 42 were positive by both assays, 13 were positive only by the assay with the agarose gel, and 3 were positive only by the assay with the fluorescent probe. To define the subtype of HSV DNA detected in the screening assay, we also designed one set of primers which amplifies the gG regions of both types of HSV and probes which are specific to either HSV-1 (gG1) or HSV-2 (gG2). These probes were labeled with different fluorescent dyes (6-carboxyfluorescein for gG2 and 6-hexachlorofluorescein for gG1) to enable detection in a single PCR. In mixing experiments the probes discriminated the correct subtype in mixtures with up to a 7-log-higher concentration of the opposite subtype. The PCR typing results showed 100% concordance with the results obtained by assays with monoclonal antibodies against HSV-1 or HSV-2. Thus, while the real-time PCR is slightly less sensitive than the gel-based liquid hybridization system, the high throughput, the lack of contamination during processing, the better reproducibility, and the better ability to type the isolates rapidly make the real-time PCR a valuable tool for clinical investigation and diagnosis of HSV infection.


2009 ◽  
Vol 45 (4) ◽  
pp. 304-310 ◽  
Author(s):  
Elisa Leo ◽  
Simona Venturoli ◽  
Monica Cricca ◽  
Monica Musiani ◽  
Marialuisa Zerbini

2016 ◽  
Vol 120 (5) ◽  
pp. 1346-1356 ◽  
Author(s):  
G. Otti ◽  
S. Bouvaine ◽  
B. Kimata ◽  
G. Mkamillo ◽  
P.L. Kumar ◽  
...  

Author(s):  
Leslie A. Mitchell ◽  
Nick A. Phillips ◽  
Andrea Lafont ◽  
James A. Martin ◽  
Rupal Cutting ◽  
...  

2019 ◽  
Author(s):  
L. Leach ◽  
A. Russell ◽  
Y. Zhu ◽  
S. Chaturvedi ◽  
V. Chaturvedi

ABSTRACTThe multidrug-resistant yeast pathogen Candida auris continues to cause outbreaks and clusters of clinical cases worldwide. Previously, we developed a real-time PCR assay for the detection of C. auris from surveillance samples (Leach et al. JCM. 2018: 56, e01223-17). The assay played a crucial role in the ongoing investigations of C. auris outbreak in New York City. To ease the implementation of the assay in other laboratories, we developed an automated sample-to-result real-time C. auris PCR assay using BD MAX™ open system. We optimized sample extraction at three different temperatures and four incubation periods. Sensitivity was determined using eight pools of patient samples, and specificity was calculated using four clades of C. auris, and closely and distantly related yeasts. Three independent extractions and testing of two patient sample pools in the quadruplicate yielded assay precision. BD MAX™ optimum assay conditions were: DNA extraction at 75°C for 20 min, and the use of PerfeCTa Multiplex qPCR ToughMix. The limit of detection (LOD) of the assay was one C. auris CFU/PCR reaction. We detected all four clades of C. auris without cross-reactivity to other yeasts. Of the 110 patient surveillance samples tested, 50 were positive for C. auris using the BD MAX™ System with 96% clinical sensitivity and 94% accuracy compared to the manual assay. BD MAX™ assay allows high-throughput C. auris screening of 180 surveillance samples in a 12-hour workday.


Sign in / Sign up

Export Citation Format

Share Document