scholarly journals Instrumented fusion of thoracolumbar fracture with type I mineralized collagen matrix combined with autogenous bone marrow as a bone graft substitute: a four-case report

2006 ◽  
Vol 15 (S5) ◽  
pp. 630-635 ◽  
Author(s):  
Antonio A. Faundez ◽  
Sofia Taylor ◽  
André J. Kaelin
RSBO ◽  
2017 ◽  
Vol 1 (2) ◽  
pp. 114
Author(s):  
Priscila Alves Teixeira ◽  
Carmen L. Mueller Storrer ◽  
Felipe Rychuv Santos ◽  
Aline Monise Sebastiani ◽  
Tatiana Miranda Deliberador

The periodontal treatment of teeth with furcation defect is clinically challenging. In cases of class II furcation defects, the regenerative surgery shows low morbidity and good prognosis when correctly indicated. The aim of the presentstudy is to report a treatment option for class II furcation defect through autogenous bone graft associated with the Bichat’s fat pad. Case report: A 59-year-old female patient was diagnosed with class II furcation defect in the left mandibular first molar. The treatment comprised surgical reconstruction of the defect with a combination of maxillary tuberosity bone graft and Bichat’s fat pad. The clinical and radiographic follow-up of 180 days showed bone formation inthe furcation area and absence of probing depth. Conclusion: An association of autogenous graft form the maxillary tuberosity with a Bichat’s fat pad proved to be a safe, low cost, and effective therapy for the regenerative treatment of class II furcation.


2001 ◽  
Vol 59 (3A) ◽  
pp. 582-586 ◽  
Author(s):  
Rosana Herminia Scola ◽  
Lineu Cesar Werneck ◽  
Cássio Slompo Ramos ◽  
Ricardo Pasquini ◽  
Hans Graf ◽  
...  

The authors report one case of amyloidosis associated with muscular pseudohypertrophy in a 46-year-old woman, who developed weakness, macroglossia and muscle hypertrophy associated with primary systemic amyloidosis. Electromyography showed a myopathic pattern and bilateral carpal tunnel syndrome. The muscle biopsy presented with a type I and II fiber hypertrophy and infiltration of amyloid material in the interstitious space and artery walls. She underwent bone marrow transplantation with stabilization and subjective improvement of the clinical picture.


2003 ◽  
Vol 774 ◽  
Author(s):  
Matthew J. Olszta ◽  
Elliot P. Douglas ◽  
Laurie B. Gower

AbstractIntrafibrillar mineralization of type-I collagen with hydroxyapatite (HA) is the basis of the complex biological composite known as bone, which from a material science perspective is a fascinating example of an interpenetrating bioceramic composite. Using a polymer-induced liquid-precursor (PILP) process, collagen substrates were highly infiltrated with a liquid-phase mineral precursor to calcium carbonate (CaCO3). At sections of partially mineralized collagen, banded mineral patterns were observed perpendicular to the collagen fibrils, while other fibrils were completely mineralized. An acid etch, used to preferentially remove superficial mineral, further revealed such banded patterns in fully mineralized samples. Removal of the collagen matrix with a dilute hypochlorite solution showed an interpenetrating mineral phase, with mineral disks that spanned the diameter of the pre-existing collagen fibrils, supporting our hypothesis that intrafibrillar mineralization can be achieved via capillary action applied to a liquid-phase mineral precursor.


Materials ◽  
2020 ◽  
Vol 13 (19) ◽  
pp. 4312
Author(s):  
Federico Morosato ◽  
Francesco Traina ◽  
Ronja A. Schierjott ◽  
Georg Hettich ◽  
Thomas M. Grupp ◽  
...  

Hip implant failure is mainly due to aseptic loosening of the cotyle and is typically accompanied by defects in the acetabular region. Revision surgery aims to repair such defects before implantation by means of reconstruction materials, whose morselized bone graft represents the gold standard. Due to the limited availability of bone tissue, synthetic substitutes are also used. The aim of this study was to evaluate if a synthetic fully resorbable tri-calcium phosphate-based substitute can provide adequate mechanical stability when employed to restore severe, contained defects, in comparison with morselized bone graft. Five cadaveric pelvises were adopted, one side was reconstructed with morselized bone graft and the other with the synthetic substitute, consisting of dense calcium phosphate granules within a collagen matrix. During the biomechanical test, cyclic load packages of increasing magnitude were applied to each specimen until failure. Bone/implant motions were measured through Digital Image Correlation and were expressed in terms of permanent and inducible translations and rotations. The reconstruction types exhibited a similar behavior, consisting of an initial settling trend followed by failure as bone fracture (i.e., no failure of the reconstruction material). When 2.2 Body Weight was applied, the permanent translations were not significantly different between the two reconstructions (p = 0.06–1.0) and were below 1.0 mm. Similarly, the inducible translations did not differ significantly (p = 0.06–1.0) and were below 0.160 mm. Rotations presented the same order of magnitude but were qualitatively different. Overall, the synthetic substitute provided adequate mechanical stability in comparison with morselized bone graft, thus representing a reliable alternative to treat severe, contained acetabular defects.


Sign in / Sign up

Export Citation Format

Share Document