Time dependent failure rate and marginal bone loss of implant supported prostheses: a 15-year follow-up study

2000 ◽  
Vol 4 (1) ◽  
pp. 0013-0020 ◽  
Author(s):  
K. Snauwaert ◽  
J. Duyck ◽  
D. van Steenberghe ◽  
M. Quirynen ◽  
I. Naert
2001 ◽  
Vol 120 (5) ◽  
pp. A628-A628
Author(s):  
P CLEMENS ◽  
V HAWIG ◽  
M MUELLER ◽  
J SCAENZLIN ◽  
B KLUMP ◽  
...  

2021 ◽  
Vol 12 (2) ◽  
pp. 35
Author(s):  
Livia Nastri ◽  
Ludovica Nucci ◽  
Vincenzo Grassia ◽  
Rino Miraldi

Single tooth implant restorations in the aesthetic area are a demanding challenge. If a complete osseointegration is mandatory, the final result has to result in a higher standard of biomimetic and soft tissue health among natural teeth. This outcome is traditionally pursued by cementing crowns over individualized abutments. However, in recent years, the need for controlling peri-implant health and the preference towards a retrievable solution has led to an increase in screw-retained crowns, which is not always applicable when the implant axis is not ideal. In the aesthetic area, the use of a novel technical solution represented by the angled screw channel (ASC) of the abutment has been proposed in order to match the advantages of the screwed solution with the aesthetic demands. The aim of this study was to compare ASC crowns to cemented crowns (CC) in single implant restorations using the white esthetic score (WES) and pink esthetic score (PES) at the crown delivery and at a follow-up of a minimum of 2 years. Peri-implant health and marginal bone loss (MBL) were also evaluated. The mean follow-up was 44.3 months, with a mean MBL of 0.22 mm in the ASC group and 0.29 mm in the CC group. The total WES/PES score was 16.6 for ASC, compared with 17.3 for CC at baseline, and 16.2 and 17.1, respectively, at follow-up. Both of the groups reached a high WES/PES, and this was maintained over time, without signs of peri-implant diseases or bone loss, regardless of the choice of connection. In conclusion, ASC can be adopted in cases where the implant axis is not ideal, with aesthetic and functional results that are comparable to implants restored by cemented crowns.


2015 ◽  
Vol 38 (14) ◽  
pp. 1407-1414
Author(s):  
Juha Suuronen ◽  
Samu Sjöblom ◽  
Risto Honkanen ◽  
Heli Koivumaa-Honkanen ◽  
Heikki Kröger ◽  
...  

2020 ◽  
Vol 21 (1) ◽  
Author(s):  
Tuuli H. Suominen ◽  
Johanna Edgren ◽  
Anu Salpakoski ◽  
Mauri Kallinen ◽  
Tomas Cervinka ◽  
...  

2005 ◽  
Vol 16 (12) ◽  
pp. 1841-1848 ◽  
Author(s):  
Joonas Sirola ◽  
Marjo Tuppurainen ◽  
Risto Honkanen ◽  
Jukka S. Jurvelin ◽  
Heikki Kröger

1997 ◽  
Vol 60 (4) ◽  
pp. 348-353 ◽  
Author(s):  
M. A. Mayoux-Benhamou ◽  
F. Bagheri ◽  
C. Roux ◽  
G. R. Auleley ◽  
J. P. Rabourdin ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document