scholarly journals The feasibility of a noise elimination method using continuous wave response of therapeutic ultrasound signals for ultrasonic monitoring of high-intensity focused ultrasound treatment

Author(s):  
Ryo Takagi ◽  
Toshikatsu Washio ◽  
Yoshihiko Koseki

Abstract Purpose In this study, the robustness and feasibility of a noise elimination method using continuous wave response of therapeutic ultrasound signals were investigated when tissue samples were moved to simulate the respiration-induced movements of the different organs during actual high-intensity focused ultrasound (HIFU) treatment. In addition to that, the failure conditions of the proposed algorithm were also investigated. Methods The proposed method was applied to cases where tissue samples were moved along both the lateral and axial directions of the HIFU transducer to simulate respiration-induced motions during HIFU treatment, and the noise reduction level was investigated. In this experiment, the speed of movement was increased from 10 to 40 mm/s to simulate the actual movement of the tissue during HIFU exposure, with the intensity and driving frequency of HIFU set to 1.0–5.0 kW/cm2 and 1.67 MHz, respectively. To investigate the failure conditions of the proposed algorithm, the proposed method was applied with the HIFU focus located at the boundary between the phantom and water to easily cause cavitation bubbles. The intensity of HIFU was set to 10 kW/cm2. Results Almost all HIFU noise was constantly able to be eliminated using the proposed method when the phantom was moved along the lateral and axial directions during HIFU exposure. The noise reduction level (PRL in this study) at an intensity of 1.0, 3.0, and 5.0 kW/cm2 was in the range of 28–32, 38–40, and 42–45 dB, respectively. On the other hand, HIFU noise was not basically eliminated during HIFU exposure after applying the proposed method in the case of cavitation generation at the HIFU focus. Conclusions The proposed method can be applicable even if homogeneous tissues or organs move axially or laterally to the direction of HIFU exposure because of breathing. A condition under which the proposed algorithm failed was when instantaneous tissue changes such as cavitation bubble generation occurred in the tissue, at which time the reflected continuous wave response became less steady.

2014 ◽  
Vol 2014 ◽  
pp. 1-11 ◽  
Author(s):  
Yufeng Zhou

Pancreatic cancer is under high mortality but has few effective treatment modalities. High-intensity focused ultrasound (HIFU) is becoming an emerging approach of noninvasively ablating solid tumor in clinics. A variety of solid tumors have been tried on thousands of patients in the last fifteen years with great success. The principle, mechanism, and clinical outcome of HIFU were introduced first. All 3022 clinical cases of HIFU treatment for the advanced pancreatic cancer alone or in combination with chemotherapy or radiotherapy in 241 published papers were reviewed and summarized for its efficacy, pain relief, clinical benefit rate, survival, Karnofsky performance scale (KPS) score, changes in tumor size, occurrence of echogenicity, serum level, diagnostic assessment of outcome, and associated complications. Immune response induced by HIFU ablation may become an effective way of cancer treatment. Comments for a better outcome and current challenges of HIFU technology are also covered.


2003 ◽  
Vol 113 (4) ◽  
pp. 2308-2308
Author(s):  
Narendra Sanghvi ◽  
Adam Wunderlich ◽  
Ralf Seip ◽  
Jahangir Tavakkoli ◽  
Kris Dines ◽  
...  

2021 ◽  
Author(s):  
Siavash Rahimian ◽  
Jahan Tavakkoli

Background This study investigated the dynamic changes of tissue attenuation coefficients before, during, and after high-intensity focused ultrasound (HIFU) treatment at different total acoustic powers (TAP) in ex vivo porcine muscle tissue. It further assessed the reliability of employing changes in tissue attenuation coefficient parameters as potential indicators of tissue thermal damage. Methods Two-dimensional pulse-echo radio frequency (RF) data were acquired before, during, and after HIFU exposure to estimate changes in least squares attenuation coefficient slope (Δβ) and attenuation coefficient intercept (Δα0). Using the acquired RF data, Δβ and Δα0 images, along with conventional B-mode ultrasound images, were constructed. The dynamic changes of Δβ and Δα0, averaged in the region of interest, were correlated with B-mode images obtained during the HIFU treatment process. Results At a HIFU exposure duration of 40 s and various HIFU intensities (737–1,068 W/cm2), Δβ and Δα0 increased rapidly to values in the ranges 1.5–2.5 dB/(MHz.cm) and 4–5 dB/cm, respectively. This rapid increase was accompanied with the appearance of bubble clouds in the B-mode images. Bubble activities appeared as strong hyperechoic regions in the B-mode images and caused fluctuations in the estimated Δβ and Δα0 values. After the treatment, Δβ and Δα0 values gradually decreased, accompanied by fade-out of hyperechoic spots in the B-mode images. At 10 min after the treatment, they reached values in ranges 0.75–1 dB/(MHz.cm) and 1–1.5 dB/cm, respectively, and remained stable within those ranges. At a long HIFU exposure duration of around 10 min and low HIFU intensity (117 W/cm2), Δβ and Δα0 gradually increased to values of 2.2 dB/(MHz.cm) and 2.2 dB/cm, respectively. This increase was not accompanied with the appearance of bubble clouds in the B-mode images. After HIFU treatment, Δβ and Δα0 gradually decreased to values of 1.8 dB/(MHz.cm) and 1.5 dB/cm, respectively, and remained stable at those values. Conclusions Δβ and Δα0 estimations were both potentially reliable indicators of tissue thermal damage. In addition, Δβ and Δα0 images both had significantly higher contrast-to-speckle ratios compared to the conventional B-mode images and outperformed the B-mode images in detecting HIFU thermal lesions at all investigated TAPs and exposure durations.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
K. J. Anneveldt ◽  
I. M. Verpalen ◽  
I. M. Nijholt ◽  
J. R. Dijkstra ◽  
R. D. van den Hoed ◽  
...  

Abstract Background Although promising results have been reported for Magnetic Resonance image-guided High-Intensity Focused Ultrasound (MR-HIFU) treatment of uterine fibroids, this treatment is not yet widely implemented in clinical practice. During the implementation of a new technology, lessons are learned and an institutional learning-curve often has to be completed. The primary aim of our prospective cohort study was to characterize our learning-curve based on our clinical outcomes. Secondary aims included identifying our lessons learned during implementation of MR-HIFU on a technical, patient selection, patient counseling, medical specialists and organizational level. Results Our first seventy patients showed significant symptom reduction and improvement of quality of life at 3, 6 and 12 months after MR-HIFU treatment compared to baseline. After the first 25 cases, a clear plateau phase was reached in terms of failed treatments. The median non-perfused volume percentage of these first 25 treatments was 44.6% (range: 0–99.7), compared to a median of 74.7% (range: 0–120.6) for the subsequent treatments. Conclusions Our findings describe the learning-curve during the implementation of MR-HIFU and include straightforward suggestions to shorten learning-curves for future users. Moreover, the lessons we learned on technique, patient selection, patient counseling, medical specialists and organization, together with the provided supplements, may be of benefit to other institutions aiming to implement MR-HIFU treatment of uterine fibroids. Trial registration ISRCTN14634593. Registered January 12, 2021—Retrospectively registered, https://www.isrctn.com/ISRCTN14634593.


mSphere ◽  
2020 ◽  
Vol 5 (6) ◽  
pp. e00859-20
Author(s):  
Juhua Xiao ◽  
Xin Zhou ◽  
Ye Luo ◽  
Shuang Wang ◽  
Zhili Yang ◽  
...  

ABSTRACTHigh-intensity focused ultrasound (HIFU), a noninvasive ablation therapy that has been widely used clinically in ablation of solid tumors, induces immune sensitization. We therefore in this study investigated whether HIFU treatment could enhance the efficacy of a herpes simplex virus 2 (HSV-2) vaccine. First, we observed that in HSV-2-positive cervical intraepithelial neoplasia (CIN) II patients, HIFU treatment induced significantly higher anti-HSV-2 neutralization response than surgical removal. Next, we tested the efficacy of HIFU-treated, UV-inactivated HSV-2-infected cells as a proof-of-concept vaccine in mice. Our data showed that HIFU-treated formulation significantly enhanced HSV-2 antibody titers and neutralization titers, compared to UV-, microwave (MW)-, or freeze-thaw (FT)-treated formulations. HIFU treatment also promoted the Th1/2 cell-mediated response. A long-term full protection was observed in mice that received the HIFU-treated formulation, and no weight loss was detected. Our findings indicate that the novel application of HIFU in vaccine production may represent a rational way to improve vaccine efficacy.IMPORTANCE High-intensity focused ultrasound (HIFU) is mainly used in tumor ablation and tumor vaccinology study. It has been shown to induce immune sensitization and enhance tumor responsiveness to other therapies. Our study has shown enhanced anti-HSV-2 response in HIFU-treated CIN II patients. Furthermore, in a murine model, we have demonstrated that HIFU-treated HSV-2 vaccine induced long-term protective immunity against lethal challenge. Our findings indicate that the novel application of HIFU in vaccine production may represent a rational way to improve vaccine efficacy.