Influence of near-fault ground motion characteristics on the seismic response of cable-stayed bridges

2020 ◽  
Vol 18 (14) ◽  
pp. 6375-6403
Author(s):  
Chao Zhang ◽  
Jian-bing Lu ◽  
Hong-yu Jia ◽  
Zhi-chao Lai ◽  
Xu Li ◽  
...  
2020 ◽  
Vol 2020 ◽  
pp. 1-13
Author(s):  
Chunyang Liu ◽  
Peng Sun ◽  
Ruofan Shi

This paper proposes two kinds of arrangements of buckling-restrained brace dampers to strengthen soft-first-storey structures locally. Two types of near-fault ground motion, with and without pulse, were selected for a study of the seismic response characteristics of soft-first-storey structures with and without buckling-restrained brace dampers, and the effects of different bracing arrangements on improving the seismic performance of soft-first-storey structures were recognized. The results show that, compared with pulse-free ground motion, near-fault pulsed ground motion results in a more severe seismic response in soft-first-storey frame structures, leading to more serious and rapid destruction of the main structure. Buckling-restrained brace dampers have an obvious energy dissipation effect, play a better role in protecting the main structure, and have good practicality. Compared with structures in which the buckling-restrained brace dampers are arranged only on the bottommost layer, the bottom-four-layer-support structure is more advantageous in terms of seismic performance.


2020 ◽  
Vol 36 (3) ◽  
pp. 1485-1516
Author(s):  
Jui-Liang Lin ◽  
Wen-Hui Chen ◽  
Fu-Pei Hsiao ◽  
Yuan-Tao Weng ◽  
Wen-Cheng Shen ◽  
...  

A shaking table test of a three-story reinforced concrete (RC) building was conducted. The tested building is vertically irregular because of the first story’s elevated height and the third story’s added RC walls. In addition to far-field ground motions, near-fault ground motions were exerted on this building. A numerical model of the three-story building was constructed. Comparing with the test results indicates that the numerical model is satisfactory for simulating the seismic response of the three-story building. This validated numerical model was then further applied to look into two issues: the effective section rigidities of RC members and the effects of near-fault ground motions. The study results show the magnitude of the possible discrepancy between the actual seismic response and the estimated seismic response, when the effective section rigidities of the RC members are treated as in common practice. An incremental dynamic analysis of the three-story RC building subjected to one far-field and one near-fault ground motion, denoted as CHY047 and TCU052, respectively, was conducted. In comparison with the far-field ground motion, the near-fault ground motion is more destructive to this building. In addition, the effect of the selected near-fault ground motion (i.e. TCU052) on the building’s collapse is clearly identified.


2013 ◽  
Vol 353-356 ◽  
pp. 1867-1870
Author(s):  
Yan Li Shen ◽  
Xiu Li Du ◽  
Qing Shan Yang

For estimating seismic response of pier-structure under near-fault ground motion, The typical pulse-type near-fault ground motion records were chosen to establish a record base, and three pier models with different natural period were established; The non-elastic response spectral displacement of ground motion was used to estimate the nonlinear response; The yield displacement of the nonlinear oscillator was defined based on the static pushover analysis result, and its influence on response estimation was studied. The study result is important for structural seismic response estimation by using the non-elastic response spectral displacement and the probability-based seismic performance evaluation.


Sign in / Sign up

Export Citation Format

Share Document