Thermal environment induced by jatropha oil pool fire in a compartment

2016 ◽  
Vol 127 (3) ◽  
pp. 2397-2415 ◽  
Author(s):  
Avinash Chaudhary ◽  
Akhilesh Gupta ◽  
Surendra Kumar ◽  
Ravi Kumar
2018 ◽  
Vol 6 ◽  
pp. 104-127
Author(s):  
Avinash Chaudhary ◽  
Akhilesh Gupta ◽  
Surendra Kumar
Keyword(s):  

2021 ◽  
pp. 073490412110301
Author(s):  
Yawei Wang ◽  
Gaowan Zou ◽  
Conglin Liu ◽  
Y Gao

The Halon 1301 fixed gas fire extinguishing system used in ship engine rooms has been banned from production all over the world, because halon destroys the ozone layer. Therefore, it is necessary to find an environmentally friendly, compatible and efficient alternative firefighting system. In this study, we performed fire extinguishing tests in an ISO9705 standard room for four alternative fire extinguishing agents, as well as Halon 1301. The fire extinguishing efficiency of each agent was determined based on its cooling effect, dilution effect of oxygen concentration, the extinguishing time of the oil pool fire and the re-ignition probability of the wood stack. The test results provide data support for the selection of alternatives of Halon 1301 from the aspect of fire extinguishing efficiency. Among these results, Novec 1230 had the best ability to put out the oil pool fire, and HFC-227ea suppressed the wood stack fire the best. The difference between the cooling ability of each fire extinguishing agent was small, and the inert gas (IG-541) displayed the best ability to dilute oxygen. Hot aerosol required the longest time to extinguish fire. Consequently, under the existing design standards, HFC-227ea had the better firefighting efficiency, more suitable to replace Halon 1301.


Fuel ◽  
2018 ◽  
Vol 234 ◽  
pp. 464-472 ◽  
Author(s):  
Depeng Kong ◽  
Zhen Zhang ◽  
Ping Ping ◽  
Guoming Chen ◽  
Xu He ◽  
...  

2018 ◽  
Vol 31 (5) ◽  
pp. 436-449 ◽  
Author(s):  
Depeng Kong ◽  
Zhen Zhang ◽  
Ping Ping ◽  
Xu He ◽  
Hanbing Yang

1986 ◽  
Vol 1 ◽  
pp. 911-918 ◽  
Author(s):  
Takaaki Yamaguchi ◽  
K. Wakasa
Keyword(s):  

2018 ◽  
Vol 211 ◽  
pp. 94-103 ◽  
Author(s):  
Tao Chen ◽  
Xue-cheng Fu ◽  
Zhi-ming Bao ◽  
Jian-jun Xia ◽  
Rong-ji Wang

2013 ◽  
Vol 790 ◽  
pp. 686-689
Author(s):  
Chen Jian ◽  
Xu Yan Ying ◽  
Wang Yan Sheng

The objective of this work is to investigate the diesel analog pool fire with water mist .For this purpose, a series of water mist fire suppression experiment are carried out by changing the nozzle operating pressure, the source of fire power, opening and closing the exhaust fan to analyze the inhibitory effect of water mist to oil pool fire in the enclosed compartment of 5.0m × 5.0m × 3.0m. The results shows that extinguishing efficiency first increases and then decreases when the nozzle operating pressure increases from 8MPa to 12MPa, reaching the highest efficiency at 10MPa; increasing the power of the source of fire, the burning speed increases and the water mist fire extinguishing efficiency decreases; fresh oxygen coming in when smoke exhaust fan is turned on and water mist fire suppression efficiency decreases. Using FDS to simulate the water mist extinguishing oil pool fire, the predict temperature field and extinguishing time are basically consistent with the experimental results. In the actual applications of water mist fire suppression systems engineering, we can use the FDS field simulation methods to predict the characteristic parameters variation of the fire fighting fire temperature and component concentration, which is significant to the fire extinguishing system optimized design.


Sign in / Sign up

Export Citation Format

Share Document