Experimental and Numerical Study on the Suppression of Pool Fire with Water Mist

2013 ◽  
Vol 790 ◽  
pp. 686-689
Author(s):  
Chen Jian ◽  
Xu Yan Ying ◽  
Wang Yan Sheng

The objective of this work is to investigate the diesel analog pool fire with water mist .For this purpose, a series of water mist fire suppression experiment are carried out by changing the nozzle operating pressure, the source of fire power, opening and closing the exhaust fan to analyze the inhibitory effect of water mist to oil pool fire in the enclosed compartment of 5.0m × 5.0m × 3.0m. The results shows that extinguishing efficiency first increases and then decreases when the nozzle operating pressure increases from 8MPa to 12MPa, reaching the highest efficiency at 10MPa; increasing the power of the source of fire, the burning speed increases and the water mist fire extinguishing efficiency decreases; fresh oxygen coming in when smoke exhaust fan is turned on and water mist fire suppression efficiency decreases. Using FDS to simulate the water mist extinguishing oil pool fire, the predict temperature field and extinguishing time are basically consistent with the experimental results. In the actual applications of water mist fire suppression systems engineering, we can use the FDS field simulation methods to predict the characteristic parameters variation of the fire fighting fire temperature and component concentration, which is significant to the fire extinguishing system optimized design.

2014 ◽  
Vol 1016 ◽  
pp. 819-823
Author(s):  
Xue Han ◽  
Jun Qin ◽  
Jun Jun Tao ◽  
Ming Hui Feng

Water mist technology has been developed and regarded as a promising substitute fire-extinguishing agent in spacecraft. In this paper, a numerical simulation method is introduced to investigate the effect of water mist size, velocity and flow rateon the fire suppressionefficiencyin microgravity. The fire extinguishing efficiency is better for the finer water mist in microgravity due to better heat transfer and more rapid vaporization. The evaporation cooling is the dominant mechanism of fire suppression in microgravity.As for the water mist velocity, the performance of fire suppression is affected slightly in microgravity. The results on the effect of water flow rate show that the flow rate should be higher than a critical value to suppress the fire effectively.


2016 ◽  
pp. 895-901 ◽  
Author(s):  
Pei Zhu ◽  
Xishi Wang ◽  
Zhigang Wang ◽  
Haiyong Cong ◽  
Xiaomin Ni

2014 ◽  
Vol 67 ◽  
pp. 1-12 ◽  
Author(s):  
A. Jenft ◽  
A. Collin ◽  
P. Boulet ◽  
G. Pianet ◽  
A. Breton ◽  
...  

2013 ◽  
Vol 392 ◽  
pp. 116-121
Author(s):  
Qiang Liang ◽  
Yan Feng Li ◽  
Guo Cai Yao ◽  
Xue Fei Xing

A new effervescent atomized water mist fire extinguishing equipment was developed by combining the characters of water mist and effervescent atomization. A series of wood crib and gasoline pool fire suppression experiments were performed using the equipment. The fire extinguishment time, temperature and radiation heat flux of the flame were measured, and then the process of putting out different type fire was analyzed. A wood crib fire of 0.6A can be put out in 180 seconds using water mist produced by effervescent atomization equipment. Only 38 seconds was taken to suppress a gasoline fire.


2021 ◽  
Vol 11 (7) ◽  
pp. 3247
Author(s):  
Dong Hwan Kim ◽  
Chi Young Lee ◽  
Chang Bo Oh

In this study, the effects of discharge area and atomizing gas type in a twin-fluid atomizer on heptane pool fire-extinguishing performance were investigated under the heat release rate conditions of 1.17 and 5.23 kW in an enclosed chamber. Large and small full cone twin-fluid atomizers were prepared. Nitrogen and air were used as atomizing gases. With respect to the droplet size of water mist, as the water and air flow rates decreased and increased, respectively, the Sauter mean diameter (SMD) of the water mist decreased. The SMD of large and small atomizers were in the range of approximately 12–60 and 12–49 μm, respectively. With respect to the discharge area effect, the small atomizer exhibited a shorter extinguishing time, lower peak surface temperature, and higher minimum oxygen concentration than the large atomizer. Furthermore, it was observed that the effect of the discharge area on fire-extinguishing performance is dominant under certain flow rate conditions. With respect to the atomizing gas type effect, nitrogen and air appeared to exhibit nearly similar extinguishing times, peak surface temperatures, and minimum oxygen concentrations under most flow rate conditions. Based on the present and previous studies, it was revealed that the effect of atomizing gas type on fire-extinguishing performance is dependent on the relative positions of the discharged flow and fire source.


2021 ◽  
pp. 073490412110301
Author(s):  
Yawei Wang ◽  
Gaowan Zou ◽  
Conglin Liu ◽  
Y Gao

The Halon 1301 fixed gas fire extinguishing system used in ship engine rooms has been banned from production all over the world, because halon destroys the ozone layer. Therefore, it is necessary to find an environmentally friendly, compatible and efficient alternative firefighting system. In this study, we performed fire extinguishing tests in an ISO9705 standard room for four alternative fire extinguishing agents, as well as Halon 1301. The fire extinguishing efficiency of each agent was determined based on its cooling effect, dilution effect of oxygen concentration, the extinguishing time of the oil pool fire and the re-ignition probability of the wood stack. The test results provide data support for the selection of alternatives of Halon 1301 from the aspect of fire extinguishing efficiency. Among these results, Novec 1230 had the best ability to put out the oil pool fire, and HFC-227ea suppressed the wood stack fire the best. The difference between the cooling ability of each fire extinguishing agent was small, and the inert gas (IG-541) displayed the best ability to dilute oxygen. Hot aerosol required the longest time to extinguish fire. Consequently, under the existing design standards, HFC-227ea had the better firefighting efficiency, more suitable to replace Halon 1301.


2014 ◽  
Vol 915-916 ◽  
pp. 356-361
Author(s):  
Zheng Wen Xie

FDS simulation software was used to establish the full size lampblack physics model of single wind pipe, using the orthogonal design method design of analog calculation conditions, research in the nozzle pressure, the droplet radius, nozzle, flow quantity and injection angle parameters under different conditions of water mist fire extinguishing effect. Based on a full-scale combustion and water mist fire extinguishing experiment, the water mist fire suppression was observed and test analysis etc, to better understand the flue water mist fire extinguishing feasibility, provides the theory basis for the design of efficient, reliable flue fire extinguishing system.


2013 ◽  
Vol 790 ◽  
pp. 53-56
Author(s):  
Chen Jian ◽  
Xu Yan Ying ◽  
Wang Na

This paper presents an experimental study of fire suppression effectiveness with water mist containing FeCl2 additives.The investigation focuses on suppression effectiveness under various FeCl2 additives concentrations,working pressures and nozzle different height above the fire source . The experimental results show that: there is a significant impact on fire suppression effectiveness when adding FeCl2 to water mist. There is an optimum additive concentration of extinguishing fire, corresponding to the shortest extinguishing time, the least amount of water, the highest efficiency of extinguishing fire. The nozzle working pressures and nozzle position have effect on the performance of the water mist extinguishing: the greater the pressure is, the shorter water mist fire extinguishing time is. Under the same experimental conditions, the closer the water mist nozzles are to the oil pan, the shorter extinguishing time is.


Energies ◽  
2020 ◽  
Vol 13 (21) ◽  
pp. 5850
Author(s):  
Hassan Raza Shah ◽  
Kun Wang ◽  
Xu Qing Lang ◽  
Jing Wu Wang ◽  
Jing Jun Wang ◽  
...  

Recently, water has been employed as a supportive agent for the preparation of multiple suppressing agents including aqueous film forming foams (AFFF), which is combined with different kinds of gases for its various applications. In this study, the water mist is chosen for the gas-suppressing agent such as carbon dioxide. Our work investigated the suppression effects of water droplets on the n-heptane pool fire, and its mixture with carbon dioxide, respectively. The size and frequency of droplets with their effect on temperature and suppression was compared to observe the difference in the suppression. Initially, it was found that the droplets having a larger droplet size were found to be more efficient as compared to the smaller droplets with respect to the heat release rate, temperature, and radiation. Afterwards, a mixture of water droplets and carbon dioxide was simultaneously discharged to compare the difference between these two suppressing agents. It was found that the synergistic effect of the mixture has higher advantages over the use of only water suppression. It helps reduce the hot gases that surround the pool fire and allows the water mist to travel efficiently towards the fuel. Both suppression mechanisms were set to similar initial parameters that lead to different outcomes.


Sign in / Sign up