halon 1301
Recently Published Documents


TOTAL DOCUMENTS

78
(FIVE YEARS 7)

H-INDEX

7
(FIVE YEARS 1)

2021 ◽  
pp. 073490412110301
Author(s):  
Yawei Wang ◽  
Gaowan Zou ◽  
Conglin Liu ◽  
Y Gao

The Halon 1301 fixed gas fire extinguishing system used in ship engine rooms has been banned from production all over the world, because halon destroys the ozone layer. Therefore, it is necessary to find an environmentally friendly, compatible and efficient alternative firefighting system. In this study, we performed fire extinguishing tests in an ISO9705 standard room for four alternative fire extinguishing agents, as well as Halon 1301. The fire extinguishing efficiency of each agent was determined based on its cooling effect, dilution effect of oxygen concentration, the extinguishing time of the oil pool fire and the re-ignition probability of the wood stack. The test results provide data support for the selection of alternatives of Halon 1301 from the aspect of fire extinguishing efficiency. Among these results, Novec 1230 had the best ability to put out the oil pool fire, and HFC-227ea suppressed the wood stack fire the best. The difference between the cooling ability of each fire extinguishing agent was small, and the inert gas (IG-541) displayed the best ability to dilute oxygen. Hot aerosol required the longest time to extinguish fire. Consequently, under the existing design standards, HFC-227ea had the better firefighting efficiency, more suitable to replace Halon 1301.


2021 ◽  
pp. 073490412110032
Author(s):  
Yifang Xiong ◽  
Michail Diakostefanis ◽  
Akhil Dinesh ◽  
Suresh Sampath ◽  
Theoklis Nikolaidis

Fire on board an aircraft cargo compartment can lead to catastrophic consequences. Therefore, fire safety is one of the most important considerations during aircraft design and certification. Conventionally, Halon-based agents were used for fire suppression in such cases. However, an international agreement under the Montreal Protocol of 1994 banned further production of Halon and several other halocarbons considered harmful to the environment. There is therefore a requirement for new suppression agents, along with suitable system design and certification. This article aims to describe the creation of a mechanism to validate a preliminary design for fire suppression systems using Computational Fluid Dynamics and provide further guidance for fire suppression experiments in aircraft cargo compartments. Investigations were performed for the surface burning fire, one of the fire testing scenarios specified in the Minimum Performance Standard, using the numerical code Fire Dynamics Simulator. This study investigated the use and performance of nitrogen, a potential replacement for Halon 1301, as an environmentally friendly agent for cargo fire suppression. Benchmark fires using the pyrolysis model and fire design model were built for the surface-burning fire scenario. Compared with experiment results, the two Computational Fluid Dynamics models captured the suppression process with high accuracy and displayed similar temperature and gas concentration profiles. Fire consequences in response to system uncertainties were studied using fire curves with various fire growth rates. The results suggested that using nitrogen as a fire suppression agent could achieve a lower post-suppression temperature compared to a Halon 1301-based system. It can therefore be considered as a potential candidate for aircraft cargo fire suppression. Such work will feed directly into system safety assessments during the early design stages, where analyses must precede testing. Future work proposed for the application of this model can be extended to other fire scenarios such as buildings, shipping, and surface transport vehicles.


2020 ◽  
Vol 20 (6) ◽  
pp. 101-107
Author(s):  
Hyun-Bea Hwang ◽  
Se-Hong Min

The gaseous fire extinguishing agents CO<sub>2</sub>, Halon 1301, and HCFC-BLEND A and a clean fire extinguishing agent are installed and operated in 85.5%, 6.19%, 4.14%, and 4.62% of the city railroad subway stations of Korea, respectively. The fire extinguishing halon gases Halon1301 and HCFC-BLEND A currently used in city railroad subway stations are already regulated globally because of global warming and ozone layer destruction.Moreover, the use of Halon 1301 is prohibited because of the development of alternative clean fire extinguishing gas. However, newly installing and operating CO₂, unlike the use of halon gas, has not been sanctioned. In particular, even though a fire extinguishing CO₂ facility has the serious safety problem of choking accidents occurring as a result of operation in a closed space because of the characteristics of a subway station, the situation has not been improved. The Organisation for Economic Co-operation and Development designates CO₂ as the major substance causing global warming and forcibly allocates the reduction of carbon emissions to member countries through a reduction policy. Therefore, overall annual replacement of CO₂ fire extinguishing facilities installed and operated in subway stations is necessary, and the problems of fire extinguishing operation characteristics and maintenance of fire extinguishing gas facilities should be reviewed. The purpose of this work is to presentthe maintenance status of fire extinguishing gas facilities installed and operated in the city railroad subway stations of Korea. Furthermore, the preparation of measures and laws for preventing fatalities resulting from choking caused by fire extinguishing CO₂ facilities and for improving cooperation with the international environmental response is proposed.


2020 ◽  
Vol 13 (1) ◽  
pp. 73-84
Author(s):  
Tanja J. Schuck ◽  
Ann-Katrin Blank ◽  
Elisa Rittmeier ◽  
Jonathan Williams ◽  
Carl A. M. Brenninkmeijer ◽  
...  

Abstract. Measurements of halogenated trace gases in ambient air frequently rely on canister sampling followed by offline laboratory analysis. This allows for a large number of compounds to be analysed under stable conditions, maximizing measurement precision. However, individual compounds might be affected during the sampling and storage of canister samples. In order to assess halocarbon stability in whole-air samples from the upper troposphere and lowermost stratosphere, we performed stability tests using the high-resolution sampler (HIRES) air sampling unit, which is part of the Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container (CARIBIC) instrument package. The HIRES unit holds 88 lightweight stainless-steel cylinders that are pressurized in flight to 4.5 bar using metal bellows pumps. The HIRES unit was first deployed in 2010 but has up to now not been used for regular halocarbon analysis with the exception of chloromethane analysis. The sample collection unit was tested for the sampling and storage effects of 28 halogenated compounds. The focus was on compound stability in the stainless-steel canisters during storage of up to 5 weeks and on the influence of ozone, since flights take place in the upper troposphere and lowermost stratosphere with ozone mixing ratios of up to several hundred parts per billion by volume (ppbv). Most of the investigated (hydro)chlorofluorocarbons and long-lived hydrofluorocarbons were found to be stable over a storage time of up to 5 weeks and were unaltered by ozone being present during pressurization. Some compounds such as dichloromethane, trichloromethane, and tetrachloroethene started to decrease in the canisters after a storage time of more than 2 weeks or exhibited lowered mixing ratios in samples pressurized with ozone present. A few compounds such as tetrachloromethane and tribromomethane were found to be unstable in the HIRES stainless-steel canisters independent of ozone levels. Furthermore, growth was observed during storage for some species, namely for HFC-152a, HFC-23, and Halon 1301.


2019 ◽  
Vol 97 ◽  
pp. 129-134 ◽  
Author(s):  
Wei Yuan ◽  
Song Lu ◽  
Yu Guan ◽  
Yang Hu

2017 ◽  
Vol 21 (8) ◽  
pp. 4213-4231 ◽  
Author(s):  
Monique Beyer ◽  
Uwe Morgenstern ◽  
Rob van der Raaij ◽  
Heather Martindale

Abstract. We recently discovered a new groundwater age tracer, Halon-1301, which can be used to date groundwater recharged after the 1970s. In a previous study, we showed that Halon-1301 reliably inferred groundwater age at the majority of groundwater sites studied. At those sites, ages inferred from Halon-1301 agreed with those inferred from SF6 and tritium, two reliable widely applied groundwater age tracers. A few samples, however, showed reduced concentrations of Halon-1301, preventing meaningful age interpretation from its concentration. These reduced concentrations were likely a result of degradation or retardation of Halon-1301 in the aquifer. However, we could not provide full evidence for this due to the limited number of groundwater samples analysed (18 in total). In this study, we assess the potential of Halon-1301 as a groundwater age tracer for a larger dataset of groundwater samples under specific groundwater conditions, including highly anoxic young groundwater which can significantly degrade Halon-1301, to gain more information on the magnitude of occurrence and the causes of reduced Halon-1301 concentrations. In this study, we analysed 302 groundwater samples for Halon-1301, SF6, tritium and the CFCs CFC-11, CFC-12 and CFC-113. Comparison of age information inferred from the concentrations of these tracers allows assessment of the performance of Halon-1301 compared to other well established and widely used age tracers. The samples are taken from different groundwater environments in New Zealand and include anoxic and oxic waters with mean residence times ranging from < 2 years to over 150 years (tritium-free). The majority of assessed samples have reduced or elevated concentrations of CFCs, which makes it impossible to infer a reliable age using the CFCs for these samples. Halon-1301, however, reliably infers ages for CFC-contaminated waters. Three other groundwater samples were found to have elevated SF6 concentrations (contaminated). Again, at these SF6-contaminated sites, ages inferred from Halon-1301 agree with ages inferred from tritium. A few samples (14 sites) exhibit reduced concentrations of Halon-1301, which result in elevated inferred Halon-1301 ages in comparison to those inferred from SF6, tritium and/or CFC-113. Assessment of the groundwater environment at these sites gives further insight into the potential causes of Halon-1301 reduction in groundwater. Overall, Halon-1301 gives age information that matches ages inferred from SF6 and/or tritium for the majority (97 %) of the assessed groundwater sites. These findings suggest that Halon-1301 is a reasonably reliable groundwater age tracer, and is in particular significantly more reliable than the CFCs, which may have contamination and degradation problems. Halon-1301 thus has potential to become a useful groundwater age tracer where SF6 and the CFCs are compromised, and where additional independent tracers are needed to constrain complex mixing models.


2017 ◽  
Author(s):  
Monique Beyer ◽  
Uwe Morgenstern ◽  
Rob van der Raaij ◽  
Heather Martindale

Abstract. We recently discovered a new groundwater age tracer, Halon-1301, which can be used to date groundwater recharged after the 1970s. In a previous study, we showed that Halon-1301 reliably inferred groundwater age at the majority of studied groundwater sites. At those sites, ages inferred from Halon-1301 agreed with those inferred from SF6 and tritium, two reliable widely applied groundwater age tracers. A few samples, however, showed reduced concentrations of Halon-1301, preventing meaningful age interpretation from its concentration. These reduced concentrations were likely a result of degradation or retardation of Halon-1301 in the aquifer. However, we couldn’t provide full evidence for this due to the limited number of analysed groundwater samples (18 in total). In this study, we assess the potential of Halon-1301 as a groundwater age tracer for a larger dataset of groundwater samples under specific groundwater conditions, including highly anoxic young groundwater which can significantly degrade Halon-1301, to gain more information on the magnitude of occurrence and the causes of reduced Halon-1301 concentrations. In this study, we analysed 302 groundwater samples for Halon-1301, SF6, tritium and the CFCs CFC-11, CFC-12 and CFC-113. Comparison of age information inferred from the concentrations of these tracers allows assessment of the performance of Halon-1301 compared to other well established and widely used age tracers. The samples are taken from different groundwater environments in New Zealand and include anoxic and oxic waters with mean residence times ranging from