Association of albumin to creatinine ratio with urinary arsenic and metal exposure: evidence from NHANES 2015–2016

Author(s):  
Humairat H. Rahman ◽  
Danielle Niemann ◽  
Stuart H. Munson-McGee
2011 ◽  
Vol 9 (2) ◽  
pp. 90 ◽  
Author(s):  
Rohola Hemmati ◽  
Mojgan Gharipour ◽  
Hasan Shemirani ◽  
Alireza Khosravi ◽  
Elham Khosravi ◽  
...  

Background:Appearance of microalbuminuria, particularly in patients with hypertension, might be associated with a higher prevalence of left ventricular (LV) dysfunction and geometric abnormalities. This study was undertaken to determine whether high urine albumin to creatinine ratio (UACR) as a sensitive marker for microalbuminuria can be associated with LV hypertrophy (LVH) and systolic and diastolic LV dysfunction.Methods:The study population consisted of 125 consecutive patients with essential uncomplicated hypertension. Urine albumin and creatinine concentration was determined by standard methods. LVH was defined as a LV mass index >100 g/m2 of body surface area in women and >130 g/m2 in men. Echocardiographic LV systolic and diastolic parameters were measured.Results:The prevalence of microalbuminuria in patients with essential hypertension was 5.6 %. UACR was significantly no different in patients with LVH than in patients with normal LV geometry (21.26 ± 31.55 versus 17.80 ± 24.52 mg/mmol). No significant correlation was found between UACR measurement and systolic and diastolic function parameters, including early to late diastolic peak velocity (E/A) ratio (R=-0.192, p=0.038), early diastolic peak velocity to early mitral annulus velocity (E/E') ratio (R=-0.025, p=0.794), LV ejection fraction (R=0.008, p=0.929), and LV mass (R=-0.132, p=0.154). According to the receiver operator characteristic (ROC) curve analysis, UACR measurement was not an acceptable indicator of LVH with areas under the ROC curves 0.514 (95 % confidence interval 0.394–0.634). The optimal cut-off value for UACR for predicting LVH was identified at 9.4, yielding a sensitivity of 51.6 % and a specificity of 48.3 %.Conclusion:In patients with uncomplicated essential hypertension, abnormal systolic and diastolic LV function and geometry cannot be effectively predicted by the appearance of microalbuminuria.


1992 ◽  
Vol 26 (9-11) ◽  
pp. 2345-2348 ◽  
Author(s):  
C. N. Haas

A new method for the quantitative analysis of multiple toxicity data is described and illustrated using a data set on metal exposure to copepods. Positive interactions are observed for Ni-Pb and Pb-Cr, with weak negative interactions observed for Ni-Cr.


2019 ◽  
Vol 16 (2) ◽  
pp. 166-172 ◽  
Author(s):  
Linghui Deng ◽  
Changyi Wang ◽  
Shi Qiu ◽  
Haiyang Bian ◽  
Lu Wang ◽  
...  

Background: Hydration status significantly affects the clinical outcome of acute ischemic stroke (AIS) patients. Blood urea nitrogen-to-creatinine ratio (BUN/Cr) is a biomarker of hydration status. However, it is not known whether there is a relationship between BUN/Cr and three-month outcome as assessed by the modified Rankin Scale (mRS) score in AIS patients. Methods: AIS patients admitted to West China Hospital from 2012 to 2016 were prospectively and consecutively enrolled and baseline data were collected. Poor clinical outcome was defined as three-month mRS > 2. Univariate and multivariate logistic regression analyses were performed to determine the relationship between BUN/Cr and three-month outcome. Confounding factors were identified by univariate analysis. Stratified logistic regression analysis was performed to identify effect modifiers. Results: A total of 1738 patients were included in the study. BUN/Cr showed a positive correlation with the three-month outcome (OR 1.02, 95% CI 1.00-1.03, p=0.04). However, after adjusting for potential confounders, the correlation was no longer significant (p=0.95). An interaction between BUN/Cr and high-density lipoprotein (HDL) was discovered (p=0.03), with a significant correlation between BUN/Cr and three-month outcome in patients with higher HDL (OR 1.03, 95% CI 1.00-1.07, p=0.04). Conclusion: Elevated BUN/Cr is associated with poor three-month outcome in AIS patients with high HDL levels.


Sign in / Sign up

Export Citation Format

Share Document