Voltammetric behavior and determination of antidepressant drug paroxetine at carbon-based electrodes

Ionics ◽  
2015 ◽  
Vol 21 (8) ◽  
pp. 2345-2354 ◽  
Author(s):  
Mariola Brycht ◽  
Sławomira Skrzypek ◽  
Nurgul Karadas-Bakirhan ◽  
Sylwia Smarzewska ◽  
Burcin Bozal-Palabiyik ◽  
...  
Chemosensors ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 72
Author(s):  
Aurelia Magdalena Pisoschi ◽  
Aneta Pop ◽  
Florin Iordache ◽  
Loredana Stanca ◽  
Liviu Bilteanu ◽  
...  

Antioxidants are compounds that prevent or delay the oxidation process, acting at a much smaller concentration, in comparison to that of the preserved substrate. Primary antioxidants act as scavenging or chain breaking antioxidants, delaying initiation or interrupting propagation step. Secondary antioxidants quench singlet oxygen, decompose peroxides in non-radical species, chelate prooxidative metal ions, inhibit oxidative enzymes. Based on antioxidants’ reactivity, four lines of defense have been described: Preventative antioxidants, radical scavengers, repair antioxidants, and antioxidants relying on adaptation mechanisms. Carbon-based electrodes are largely employed in electroanalysis given their special features, that encompass large surface area, high electroconductivity, chemical stability, nanostructuring possibilities, facility of manufacturing at low cost, and easiness of surface modification. Largely employed methods encompass voltammetry, amperometry, biamperometry and potentiometry. Determination of key endogenous and exogenous individual antioxidants, as well as of antioxidant activity and its main contributors relied on unmodified or modified carbon electrodes, whose analytical parameters are detailed. Recent advances based on modifications with carbon-nanotubes or the use of hybrid nanocomposite materials are described. Large effective surface area, increased mass transport, electrocatalytical effects, improved sensitivity, and low detection limits in the nanomolar range were reported, with applications validated in complex media such as foodstuffs and biological samples.


2015 ◽  
Vol 5 (1) ◽  
Author(s):  
Jair C. C. Freitas ◽  
Wanderlã L. Scopel ◽  
Wendel S. Paz ◽  
Leandro V. Bernardes ◽  
Francisco E. Cunha-Filho ◽  
...  

2016 ◽  
Vol 6 (3) ◽  
pp. 265 ◽  
Author(s):  
Shreekant M Patil ◽  
Vijay P Pattar ◽  
Sharanappa T Nandibewoor

<p class="PaperAbstract"><span lang="EN-US">A sensitive and economic voltammetric method was developed for the simultaneous determination of acetaminophen (AMP) and metoclopramide (MCP) using pre-treated graphite pencil electrode (PTGPE). Compared to a graphite pencil electrode, the pre-treated electrode showed an apparent shift of the oxidation potentials in the positive direction and a notable enhancement in the current responses for both AMP and MCP. Cyclic voltammetry (CV) was used to study the voltammetric behavior of the drugs, while differential pulse voltammetry (DPV) was used to determine AMP and MCP simulta­neously. The dependence of the current on scan rate, pH and concentration was investi­gated to boost the experimental conditions for simultaneous determination. The calibra­tion curves were obtained over the range of 0.1</span><span lang="EN-US">×</span><span lang="EN-US">10<sup>-7</sup> to 1.1</span><span lang="EN-US">×</span><span lang="EN-US">10<sup>-7</sup> M, the concentration of each of both the drugs was varied by keeping the other constant, and achieved lower detection limit of 3.25 nM for AMP and 1.16 nM for MCP. The developed method was found to be selective and rapid for the simultaneous determination of AMP and MCP. The proposed method was applied simultaneously in real samples and pharmaceutical samples, with satisfactory results.</span></p>


Measurement ◽  
2021 ◽  
Vol 186 ◽  
pp. 110160
Author(s):  
Amany M. Fekry ◽  
Shereen M. Azab ◽  
Fekria M. Abou Attia ◽  
Neveen S. Ibrahim ◽  
Gehad G. Mohamed

1978 ◽  
Vol 24 (1) ◽  
pp. 36-40 ◽  
Author(s):  
G F Read ◽  
D Riad-Fahmy

Abstract A radioimmunoassay is reported for the tricyclic antidepressant drug, clomipramine (Anafranil, Geigy). Antisera generated in rabbits to clomipramine conjugated to bovine serum albumin at positions 10 and 11 were specific, cross reacting less than 5% with the pharmacologically active metabolite, desmethylclomipramine. Specificity was confirmed by the good agreement in titres observed when the samples were assayed with and without a pre-assay thin-layer chromatographic purification. Intra- and inter-assay variations were less than 8 and 13%, respectively, with a sensitivity of 175 ng/liter. Results obtained agreed well with those reported by other groups using double radioisotope derivative assays. The method has a high throughput rate, one technician can assay 200 samples in duplicate in a working week; and it is sufficiently precise, sensitive, and specific for use in routine minitoring of the drug in plasma and for checking patient compliance with dosage regimen.


2017 ◽  
Vol 231 (5) ◽  
Author(s):  
Jyothi C. Abbar ◽  
Manjunath D. Meti ◽  
Sharanappa T. Nandibewoor

AbstractThe anodic voltammetric behavior of an antibiotic drug, lincomycin hydrochloride (LIN) at gold electrode (GE) has been investigated using cyclic and linear sweep voltammetry. The dependence of the current on pH, concentration and scan rate were investigated to optimize the experimental conditions for the determination of lincomycin. The anodic peak was characterized and the process was adsorption-controlled. The number of electrons transferred in the oxidation process was calculated. In the range of 8.0×10


Sign in / Sign up

Export Citation Format

Share Document