Shake-table testing of a self-centering precast reinforced concrete frame with shear walls

2018 ◽  
Vol 17 (2) ◽  
pp. 221-233 ◽  
Author(s):  
Xilin Lu ◽  
Boya Yang ◽  
Bin Zhao
2019 ◽  
Vol 2019 ◽  
pp. 1-17 ◽  
Author(s):  
Syed Azmat Ali Shah ◽  
Junaid Shah Khan ◽  
Syed Muhammad Ali ◽  
Khan Shahzada ◽  
Waqar Ahmad ◽  
...  

Half-scaled reinforced concrete frame of two storeys and two bays with unreinforced masonry (URM) infill walls was subjected to base excitation on a shake table for seismic performance evaluation. Considering the high seismic hazard Zone IV of Pakistan, reinforcement detailing in the RC frame is provided according to special moment resisting frames (SMFRs) requirement of Building Code of Pakistan Seismic-Provisions (BCP SP-2007). The reinforced concrete frame was infilled with in-plane solid masonry walls in its interior frame, in-plane masonry walls with door and window openings in the exterior frame, out-of-plane solid masonry wall, and masonry wall with door and window openings in its interior frame. For seismic capacity qualification test, the structure was subjected to three runs of unidirectional base excitation with increasing intensity. For system identification, ambient-free vibration tests were performed at different stages of experiment. Seismic performance of brick masonry infill walls in reinforced concrete frame structures was evaluated. During the shake table test, performance of URM infill walls was satisfactory until design ground acceleration was 0.40g with a global drift of 0.23%. The test was continued till 1.24g of base acceleration. This paper presents key findings from the shake table tests, including the qualitative damage observations and quantitative force-displacement, and hysteretic response of the test specimen at different levels of excitation. Experimental results of this test will serve as a benchmark for validation of numerical and analytical models.


Author(s):  
Lusine Gurgen Karapetyan ◽  
Tigran Vardan Ter-Poghosyan

The article touches upon the comparative analysis of bearing system calculations of a multi-storey residential building with site cast reinforced concrete frame and shear wall constructed by two different methods.  In the calculation models, the shear walls are constructed from site cast reinforced concrete in the first case, and from three-layer sound and thermal insulating bearing panels in the second. The calculations have been made considering the impact of the seismic force. According to the calculation results, the dynamic parameters of the bearing systems of the buildings and the economic efficiency indicators have been compared. Considering the fact that in the recent years three-layer sound and thermal insulating panels have been widely used in the world, the study attempted to reveal the efficiency of using such panels in the Republic of Armenia.


2017 ◽  
Vol 23 (3) ◽  
pp. 444-462 ◽  
Author(s):  
Naveed Ahmad ◽  
Asif Shahzad ◽  
Muhammad Rizwan ◽  
Akhtar Naeem Khan ◽  
Syed Muhammad Ali ◽  
...  