Magnetic Solid-Phase Extraction Followed by HPLC–DAD for Highly Sensitive Determination of Phthalate Esters in Edible Vegetable Oils

Author(s):  
Yuanli Zhao ◽  
Zhenbao Zhu ◽  
Jianghua Liu ◽  
Jichao Liu ◽  
Guoliang Li
2019 ◽  
Vol 102 (5) ◽  
pp. 1624-1631 ◽  
Author(s):  
Shuo Yin ◽  
Yi Yang ◽  
Danni Yang ◽  
Yongxin Li ◽  
Yang Jiang ◽  
...  

Abstract Background: Beverages can be easily contaminated by phthalate esters (PAEs) during the production, bottling, and transportation processes. It is necessary to determine the contamination level in beverages for assessment of human exposure. Objective: In this study, magnetic solid-phase extraction (MSPE) was combined with HPLC for the determination of 11 PAEs in beverages. Methods: Self-synthesized magnetic multiwalled carbon nanotubes (m-MWCNTs) were used as the adsorbent for PAE extraction. To extract the PAEs, an appropriate amount of m-MWCNTs and NaCl was added to the beverage sample. The mixture was mixed on a vortex mixer, the magnetic sorbent was collected with the aid of a magnet, and the supernatant was removed. Then, the analytes were eluted with n-hexane–acetone (1+1, v/v). Finally, the eluent was analyzed by the HPLC method. The separation was accomplished on a Phenomenex Luna-C18 column (250 × 4.6 mm, 5 μm), and the detection wavelength was set at 225 nm. Results: The linear ranges of the method were 2–300 μg/L with correlation coefficients greater than 0.9981. The LOD and LOQ were in the range of 0.659–5.33 × 10–2 μg/L and 2.20–17.8 × 10–2 μg/L, respectively. The recoveries of the method ranged from 79.8 to 114%, with the relative SDs less than 15.8%. The established method has been successfully applied for the determination of 11 PAEs in mineral water, carbonated soft drink, tea beverage, and fruit juice samples. PAEs were detected at 0.246–34.3 μg/L in these samples. Conclusions: The m-MWCNTs are the satisfactory sorbent for MSPE because of their strong adsorption capacity for PAEs. The established MSPE-HPLC method is rapid, easy, sensitive, green, and cost-effective. It can be applied to the analysis of trace PAEs in plastic bottled beverages. Highlights: Three magnetic nanoparticles (MNPs), including Fe3O4 MNPs, m-MWCNTs, and magnetic graphene oxide, were synthesized, and m-MWCNTs were chosen as the sorbent of MSPE for PAE extraction because of their strong adsorption capacity for PAEs. An MSPE–HPLC method has been developed for the analysis of 11 phthalates in plastic bottled beverages. The established method was successfully applied to the analysis of 11 phthalates in four types of beverage samples.


Toxins ◽  
2019 ◽  
Vol 11 (11) ◽  
pp. 621 ◽  
Author(s):  
Li Yu ◽  
Fei Ma ◽  
Liangxiao Zhang ◽  
Peiwu Li

In this study, magnetic graphene nanocomposite Fe3O4/rGO was synthesized by facile one-pot solvothermal method. The nanocomposite was successfully used as magnetic solid phase extraction (MSPE) adsorbents for the determination of aflatoxins in edible vegetable oils through the π–π stacking interactions. MSPE parameters including the amount of adsorbents, extraction and desorption time, washing conditions, and the type and volume of desorption solvent were optimized. Under optimal conditions, good linear relationships were achieved. Limits of detection of this method were as low as 0.02 µg/kg and 0.01 µg/kg for aflatoxin B1 and B2, respectively. Finally, the magnetic graphene nanocomposite was successfully applied to aflatoxin analysis in vegetable oils. The results indicated that the recoveries of the B-group aflatoxins ranged from 80.4% to 106.0%, whereas the relative standard deviations (RSDs) were less than 8.1%. Owing to the simplicity, rapidity and efficiency, Fe3O4/rGO magnetic solid phase extraction coupled with high-performance liquid chromatography fluorescence with post-column photochemical derivatization (Fe3O4/rGO MSPE-HPLC-PCD-FLD) is a promising analytical method for routine and accurate determination of aflatoxins in lipid matrices.


Sign in / Sign up

Export Citation Format

Share Document