Seismic Performance of a Full-Scale Precast Concrete L-Shaped Column Frame Structure with a Grouted Connection

Author(s):  
Wei-Bin Ni ◽  
De-Hao Qiao ◽  
Hong-Wei Sun ◽  
Xu Zhang ◽  
Zhong-Wen Zhang ◽  
...  
2022 ◽  
pp. 136943322110572
Author(s):  
Xun Chong ◽  
Pu Huo ◽  
Linlin Xie ◽  
Qing Jiang ◽  
Linbing Hou ◽  
...  

A new connection measure between the precast concrete (PC) cladding panel and PC frame structure is proposed to realize a new kind of isostatic frame-cladding system. Three full-scale PC wall-frame substructures were tested under the quasi-static load. These substructures included a bare wall-frame specimen, a specimen with a cladding panel that has no opening, and a specimen with a cladding panel that has an opening in it. The damage evolution, failure mode, load-bearing capacity, deformation capacity, and energy dissipation capacity of three specimens were compared. The results indicated that the motions of the cladding panels and the main structures were uncoupled through the relative clearance of the bottom connections, and three specimens exhibited approximately identical failure modes and seismic performance. Thus, the reliability of this new isostatic system was validated.


2018 ◽  
Vol 8 (10) ◽  
pp. 1871 ◽  
Author(s):  
Xueyuan Yan ◽  
Suguo Wang ◽  
Canling Huang ◽  
Ai Qi ◽  
Chao Hong

Precast monolithic structures are increasingly applied in construction. Such a structure has a performance somewhere between that of a pure precast structure and that of a cast-in-place structure. A precast concrete frame structure is one of the most common prefabricated structural systems. The post-pouring joint is important for controlling the seismic performance of the entire precast monolithic frame structure. This paper investigated the joints of a precast prestressed concrete frame structure. A reversed cyclic loading test was carried out on two precast prestressed concrete beam–column joints that were fabricated with two different concrete strengths in the keyway area. This testing was also performed on a cast-in-place reinforced concrete joint for comparison. The phenomena such as joint crack development, yielding, and ultimate damage were observed, and the seismic performance of the proposed precast prestressed concrete joint was determined. The results showed that the precast prestressed concrete joint and the cast-in-place joint had a similar failure mode. The stiffness, bearing capacity, ductility, and energy dissipation were comparable. The hysteresis curves were full and showed that the joints had good energy dissipation. The presence of prestressing tendons limited the development of cracks in the precast beams. The concrete strength of the keyway area had little effect on the seismic performance of the precast prestressed concrete joints. The precast prestressed concrete joints had a seismic performance that was comparable to the equivalent monolithic system.


2019 ◽  
Vol 13 (03n04) ◽  
pp. 1940005 ◽  
Author(s):  
Zijian Cao ◽  
Quanwang Li

The quality of precast concrete (PC) component connections is one of the main factors that affect the seismic reliability of PC structures. China is developing PC structures in high seismic regions, and it is important to assess the effect of connection deficiency on seismic performance of PC structures. This paper presents a comprehensive method to assess the seismic reliability of PC shear wall-frame structure whose wall panels are assembled through grouted sleeve connections which are susceptible to insufficient grouting. Considering the uncertainties associated with the number, locations and loading behavior of defected sleeve connections, the probabilistic behavior of PC shear wall with defected connections is estimated through point estimate method using simulation results of the experiment-validated finite element model. Then, a simple shear wall-frame building, designed for the seismic intensity of 8 according to China’s seismic design code, is modeled on platform of OpenSees. Static pushover analyses and seismic fragility analyses are performed on the structure with different degrees of connection deficiency, to investigate the effect of deficiency occurrence rate on seismic performance. The seismic performance is significantly affected by connection deficiencies; it no longer meets the requirement of seismic design as the deficiency occurrence rate exceeds 25%, so the occurrence rate of defected connections should be controlled carefully in construction site.


2020 ◽  
Vol 10 (5) ◽  
pp. 1749
Author(s):  
Seung-Ho Choi ◽  
Jin-Ha Hwang ◽  
Sun-Jin Han ◽  
Hyo-Eun Joo ◽  
Hyun-Do Yun ◽  
...  

In recent years, a variety of strengthening methods have been developed to improve the seismic performance of reinforced concrete (RC) frame structures with non-seismic details. In this regard, this study proposes a new type of seismic strengthening method that compresses prefabricated precast concrete (PC) walls from the outside of a building. In order to verify the proposed method, a RC frame structure strengthened with precast walls was fabricated, and cyclic loading tests were performed. The results showed that specimens strengthened using the proposed method exhibited further improvements in strength, stiffness and energy dissipation capacity, compared to RC frame structures with non-seismic details. In addition, a nonlinear analysis method, capable of considering the flexural compression and shear behaviors of the walls, was suggested to analytically evaluate the structural behavior of the frame structures strengthened by the proposed method. Using this, an analysis model for frame structures strengthened with precast walls was proposed. Through the proposed model, the analysis and test results were compared in relation to stiffness, strength, and energy dissipation capacity. Then, the failure mode of the column was evaluated based on the pushover analysis. In addition, this study proposed a simplified analysis model that considered the placement of longitudinal reinforcements in shear walls.


2012 ◽  
Vol 174-177 ◽  
pp. 2012-2015
Author(s):  
Xiao Long Zhou ◽  
Ying Min Li ◽  
Lin Bo Song ◽  
Qian Tan

There are two typical seismic damage characteristics to the masonry building with frame shear wall structure at first two stories, and the lateral stiffness ratio of the third storey to the second storey is one of the key factors mostly affecting the seismic performance of this kind of building. However, some factors are not considered sufficiently in current Chinese seismic codes. According to the theory of performance-based seismic design, the seismic performance of this kind of structure is analyzed in this paper by taking time-history analysis on models which with different storey stiffness ratios. The results show that when the lateral stiffness ratio controlled in a reasonable range, the upper masonry deformation can be ensured in a range of elastic roughly, and the bottom frame can be guaranteed to have sufficient deformation and energy dissipation capacity. Finally, according to the seismic performance characteristics of masonry building with frame shear wall structure at first two stories, especially the characteristics under strong earthquakes, a method of simplified calculation model for the upper masonry is discussed in this paper.


Sign in / Sign up

Export Citation Format

Share Document