Non-Invasive Respiratory Support for Management of the Perioperative Patient: A Narrative Review

2021 ◽  
Vol 38 (4) ◽  
pp. 1746-1756
Author(s):  
Sharon Einav ◽  
Ines Lakbar ◽  
Marc Leone
Author(s):  
Denise Battaglini ◽  
Chiara Robba ◽  
Lorenzo Ball ◽  
Pedro Leme Silva ◽  
Fernanda Ferreira Cruz ◽  
...  

Author(s):  
Dejan Radovanovic ◽  
Silvia Coppola ◽  
Elisa Franceschi ◽  
Fabrizio Gervasoni ◽  
Eleonora Duscio ◽  
...  

Author(s):  
Peter A Dargaville ◽  
Andrew P Marshall ◽  
Oliver J Ladlow ◽  
Charlotte Bannink ◽  
Rohan Jayakar ◽  
...  

ObjectiveTo evaluate the performance of a rapidly responsive adaptive algorithm (VDL1.1) for automated oxygen control in preterm infants with respiratory insufficiency.DesignInterventional cross-over study of a 24-hour period of automated oxygen control compared with aggregated data from two flanking periods of manual control (12 hours each).SettingNeonatal intensive care unit.ParticipantsPreterm infants receiving non-invasive respiratory support and supplemental oxygen; median birth gestation 27 weeks (IQR 26–28) and postnatal age 17 (12–23) days.InterventionAutomated oxygen titration with the VDL1.1 algorithm, with the incoming SpO2 signal derived from a standard oximetry probe, and the computed inspired oxygen concentration (FiO2) adjustments actuated by a motorised blender. The desired SpO2 range was 90%–94%, with bedside clinicians able to make corrective manual FiO2 adjustments at all times.Main outcome measuresTarget range (TR) time (SpO2 90%–94% or 90%–100% if in air), periods of SpO2 deviation, number of manual FiO2 adjustments and oxygen requirement were compared between automated and manual control periods.ResultsIn 60 cross-over studies in 35 infants, automated oxygen titration resulted in greater TR time (manual 58 (51–64)% vs automated 81 (72–85)%, p<0.001), less time at both extremes of oxygenation and considerably fewer prolonged hypoxaemic and hyperoxaemic episodes. The algorithm functioned effectively in every infant. Manual FiO2 adjustments were infrequent during automated control (0.11 adjustments/hour), and oxygen requirements were similar (manual 28 (25–32)% and automated 26 (24–32)%, p=0.13).ConclusionThe VDL1.1 algorithm was safe and effective in SpO2 targeting in preterm infants on non-invasive respiratory support.Trial registration numberACTRN12616000300471.


Author(s):  
Jaclyn C. Omura ◽  
Maida Chen ◽  
Miriam Haviland ◽  
Susan Apkon

PURPOSE: Congenital myotonic dystrophy (CDM) results in hypotonia and acute respiratory distress at birth. Previous studies show that prolonged periods of intubation (>4 weeks) correlate with increased mortality rates. The objective is to describe the use and duration of respiratory support in newborns with CDM and how these relate to mortality. METHODS: A retrospective chart review was performed at a tertiary pediatric hospital among children with confirmed diagnosis of CDM. The main outcome measures were: mortality, duration of invasive mechanical ventilation (IMV) and non-invasive partial pressure ventilation (NIPPV), along with long-term use of respiratory support and equipment. RESULTS: A total of 18 subjects met inclusion criteria, 83%.f which had documented respiratory distress at birth, 39%.equired NIPPV, and 50%.equired intubation in the neonatal period. The earliest NIPPV was initiated at day one of life, and the latest extubation to NIPPV was at 17 days of life. CONCLUSION: This cohort required IMV for shorter periods with earlier transitions to NIPPV which suggests a possible change in practice and earlier transition to NIPPV recently. Further data are needed to determine if there is a possible correlation between the need for NIPPV/IMV and mortality rates.