A new approach to validate a musculo-skeletal human knee joint model

1994 ◽  
Vol 27 (6) ◽  
pp. 806
Author(s):  
M. Lamontagne ◽  
G. Németh ◽  
P. Wretenberg
Author(s):  
Ariful I. Bhuiyan ◽  
Nabila Shamim ◽  
Stephen Ekwaro-Osire

Abstract A three-dimensional (3D) finite element (FE) human knee joint model developed from magnetic resonance images (MRIs) has been validated with the sets of experimental results in a normalized scale. The performance of the 3D FE knee joint model has been tested, simulating a physical experiment. The experiment provided the direct measurement of anterior cruciate ligament (ACL) strains due to the forces of quadriceps muscle force (QMF) followed by ground reaction force (GRF) at low knee flexion. Accurate and precise anatomy has been obtained from segmented MRI images. The ACL strain subject to the loading was calculated and analyzed compared with the measured data from the experimental tests. The study shows that the pre-activated ACL strain, which is measured before the application of GRF, increased nonlinearly with increasing QMF before landing. However, the total ACL strain, which is measured after both QMF and GRF applied, reaches out to the limited constant value (6%) instead of crossing the ACL failure value. These results suggest that the forces generated from QMF and GRF at low flexion may not bring ACL to a failure level as presented in the experimental tests. The results of the FE model fall into the standard deviations of the 22 cadaveric knees testing results, which represents the successful mechanical modeling of ACL and the surrounding structures of the human knee joint. The model may further be used to investigate the risks of the ACL injury.


1999 ◽  
Vol 121 (6) ◽  
pp. 657-662 ◽  
Author(s):  
G. Li ◽  
J. Gil ◽  
A. Kanamori ◽  
S. L.-Y. Woo

This paper presents a three-dimensional finite element tibio-femoral joint model of a human knee that was validated using experimental data. The geometry of the joint model was obtained from magnetic resonance (MR) images of a cadaveric knee specimen. The same specimen was biomechanically tested using a robotic/universal force-moment sensor (UFS) system and knee kinematic data under anterior-posterior tibial loads (up to 100 N) were obtained. In the finite element model (FEM), cartilage was modeled as an elastic material, ligaments were represented as nonlinear elastic springs, and menisci were simulated by equivalent-resistance springs. Reference lengths (zero-load lengths) of the ligaments and stiffness of the meniscus springs were estimated using an optimization procedure that involved the minimization of the differences between the kinematics predicted by the model and those obtained experimentally. The joint kinematics and in-situ forces in the ligaments in response to axial tibial moments of up to 10 Nm were calculated using the model and were compared with published experimental data on knee specimens. It was also demonstrated that the equivalent-resistance springs representing the menisci are important for accurate calculation of knee kinematics. Thus, the methodology developed in this study can be a valuable tool for further analysis of knee joint function and could serve as a step toward the development of more advanced computational knee models.


2018 ◽  
Vol 00 (1) ◽  
pp. 109-118
Author(s):  
Enas Y. Abdullah ◽  
◽  
Naktal Moid Edan ◽  
Athraa N. Kadhim ◽  
◽  
...  

1985 ◽  
Vol 18 (7) ◽  
pp. 541
Author(s):  
Ph. Edixhoven ◽  
R. Huiskes ◽  
Th.J.G. van Rens ◽  
T.J.J.H. Slooff

2014 ◽  
Vol 15 (5) ◽  
pp. 7250-7265 ◽  
Author(s):  
Congming Zhang ◽  
Xiaochun Wei ◽  
Chongwei Chen ◽  
Kun Cao ◽  
Yongping Li ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document