High-performance liquid Chromatographic reversed-phase and normal-phase separation of diastereomeric α-ketoamide calpain inhibitors

1994 ◽  
Vol 684 (2) ◽  
pp. 243-249 ◽  
Author(s):  
Chichih Wu ◽  
Alan Akiyama ◽  
Julie Ann Straub
2019 ◽  
Vol 69 (12) ◽  
pp. 3590-3592
Author(s):  
Nela Bibire ◽  
Romeo Iulian Olariu ◽  
Luminita Agoroaei ◽  
Madalina Vieriu ◽  
Alina Diana Panainte ◽  
...  

Active pharmaceutical ingredients such as isoniazid, pyrazinamide and rifampicin are among the most important first-line anti-tuberculosis drugs. A simple, rapid and sensitive reversed phase-high performance liquid chromatographic assay method for the simultaneous determination of isoniazid, pyrazinamide and rifampicin has been developed. Separation of the interest compounds was achieved in a 10 min chromatographic run in gradient elution mode on a Zorbax SB-C18 stainless steel column (150 � 4 mm, 5 mm) using a guard column containing the same stationary phase. The gradient elution was carried out with a mobile phase of 10% CH3CN aqueous solution for channel A and 50% CH3CN in pH = 6.8 phosphate buffer (20 mM), to which 1.5 mL triethylamine were added for channel B. Quantification of the analyzed substances was carried out spectrophotometrically at 269 nm. Detection limits of 0.48 mg/L for isoniazid, 0.52 mg/L for pyrazinamide and 0.48 mg/L for rifampicin were established for the developed assay method. The present work showed that the proposed analysis method was advantageous for simple and rapid analysis of the active pharmaceutical ingredients in pharmaceuticals and biological fluids.


2007 ◽  
Vol 4 (1) ◽  
pp. 109-116 ◽  
Author(s):  
K. Basavaiah ◽  
B. C. Somashekar

A rapid, highly sensitive high performance liquid chromatographic method has been developed for the determination of finasteride(FNS) in bulk drug and in tablets. FNS was eluted from a ODS C18reversed phase column at laboratory temperature (30 ± 2°C) with a mobile phase consisting of methanol and water (80+20) at a flow rate of 1 mL min-1with UV detection at 225 nm. The retention time was ∼ 6.1 min and each analysis took not more than 10 min. Quantitation was achieved by measurement of peak area without using any internal standard. Calibration graph was linear from 2.0 to 30 μg mL-1with limits of detection (LOD) and quantification (LOQ) being 0.2 and 0.6 μg mL-1, respectively. The method was validated according to the current ICH guidelines. Within-day co efficients of variation (CV) ranged from 0.31 to 0.69% and between-day CV were in the range 1.2-3.2%. Recovery of FNS from the pharmaceutical dosage forms ranged from 97.89 – 102.9 with CV of 1.41-4.13%. The developed method was compared with the official method for FNS determination in its tablet forms.


Sign in / Sign up

Export Citation Format

Share Document