Drop interval flowmeter for low flow rate measurement

1989 ◽  
Vol 38 (3) ◽  
pp. 309-313
Author(s):  
Robert L. Hester ◽  
B.J. Barber
2021 ◽  
Vol 18 ◽  
pp. 100279
Author(s):  
Emmelyn Graham ◽  
Kerstin Thiemann ◽  
Sabrina Kartmann ◽  
Elsa Batista ◽  
Hugo Bissig ◽  
...  

2010 ◽  
Vol 158 (2) ◽  
pp. 273-279 ◽  
Author(s):  
Qi Zhang ◽  
Wenzhou Ruan ◽  
Han Wang ◽  
Youzheng Zhou ◽  
Zheyao Wang ◽  
...  

Author(s):  
Behrokh Abbasnejad ◽  
David McGloin ◽  
Lee Clemon

Abstract Direct low flow sensing is of interest to many applications in medical and biochemical industries. Low flow rate measurement is still challenging, and conventional flow sensors such as hot films, hot wires and Pitot probes are not capable of measuring very low flow rates accurately. In some applications that require flow measurement in a small diameter tubing (e.g. intravenous (IV) infusion), using such sensors also becomes mechanically impractical. Herein, a flexible laser-induced graphitic (LIG) piezoresistive flow sensor has been fabricated in a cost-effective single processing step. The capability of the LIG sensor in very low flow rate measurement has been investigated by embedding the sensor within an intravenous (IV) line. The embedded LIG hair-like sensor was tested at ambient temperature within the IV line at flow rates ranging from 0 m/s to 0.3 m/s (IV infusion free-flow rate). The LIG hair-like sensor presented in this study detects live flow rates of IV infusions with a threshold detection limit as low as 0.02 m/s. Moreover, the deformation of the LIG hair-like sensor that lead to resistance change in response to various flow rates is simulated using COMSOL Multiphysics.


2021 ◽  
Vol 104 (2) ◽  
pp. 003685042199886
Author(s):  
Wenzhe Kang ◽  
Lingjiu Zhou ◽  
Dianhai Liu ◽  
Zhengwei Wang

Previous researches has shown that inlet backflow may occur in a centrifugal pump when running at low-flow-rate conditions and have nonnegligible effects on cavitation behaviors (e.g. mass flow gain factor) and cavitation stability (e.g. cavitation surge). To analyze the influences of backflow in impeller inlet, comparative studies of cavitating flows are carried out for two typical centrifugal pumps. A series of computational fluid dynamics (CFD) simulations were carried out for the cavitating flows in two pumps, based on the RANS (Reynolds-Averaged Naiver-Stokes) solver with the turbulence model of k- ω shear stress transport and homogeneous multiphase model. The cavity volume in Pump A (with less reversed flow in impeller inlet) decreases with the decreasing of flow rate, while the cavity volume in Pump B (with obvious inlet backflow) reach the minimum values at δ = 0.1285 and then increase as the flow rate decreases. For Pump A, the mass flow gain factors are negative and the absolute values increase with the decrease of cavitation number for all calculation conditions. For Pump B, the mass flow gain factors are negative for most conditions but positive for some conditions with low flow rate coefficients and low cavitation numbers, reaching the minimum value at condition of σ = 0.151 for most cases. The development of backflow in impeller inlet is found to be the essential reason for the great differences. For Pump B, the strong shearing between backflow and main flow lead to the cavitation in inlet tube. The cavity volume in the impeller decreases while that in the inlet tube increases with the decreasing of flow rate, which make the total cavity volume reaches the minimum value at δ = 0.1285 and then the mass flow gain factor become positive. Through the transient calculations for cavitating flows in two pumps, low-frequency fluctuations of pressure and flow rate are found in Pump B at some off-designed conditions (e.g. δ = 0.107, σ = 0.195). The relations among inlet pressure, inlet flow rate, cavity volume, and backflow are analyzed in detail to understand the periodic evolution of low-frequency fluctuations. Backflow is found to be the main reason which cause the positive value of mass flow gain factor at low-flow-rate conditions. Through the transient simulations of cavitating flow, backflow is considered as an important aspect closely related to the hydraulic stability of cavitating pumping system.