A finite difference/finite element approach to dynamic soil-structure interaction modelling

1988 ◽  
Vol 29 (2) ◽  
pp. 199-205 ◽  
Author(s):  
David J. Stevens ◽  
Theodor Krauthammer
1970 ◽  
Vol 7 (2) ◽  
pp. 95-105 ◽  
Author(s):  
Ian M. Smith

An application of the displacement finite element method to axisymmetric soil–structure interaction problems is described. Since the structure and foundation are analyzed as an entity, the distribution of contact pressure does not have to be assumed. The accuracy of the method is first assessed in the analysis of some simple problems to which other solutions exist. Then a series of laboratory results and one field case record, all involving flexible structures bearing on cohesionless foundations are analyzed, the foundations being treated as elastic but inhomogeneous. Both "Winkler" and elastic solid foundations are considered and it is shown that for the latter type physically reasonable distributions of the elastic modulus do not lead to very good predictions of the deflections of the structure although the deflections within the foundation itself are in agreement with observed values.


2013 ◽  
Vol 663 ◽  
pp. 87-91
Author(s):  
Ying Bo Pang

As an effective way of passive damping, isolation technology has been widely used in all types of building structures. Currently, for its theoretical analysis, it usually follows the rigid foundation assumption and ignores soil-structure interaction, which results in calculation results distortion in conducting seismic response analysis. In this paper, three-dimensional finite element method is used to establish finite element analysis model of large chassis single-tower base isolation structure which considers and do not consider soil-structure interaction. The calculation results show that: after considering soil-structure interaction, the dynamic characteristics of the isolation structure, and seismic response are subject to varying degrees of impact.


2014 ◽  
Vol 539 ◽  
pp. 731-735 ◽  
Author(s):  
Yu Chen

In this thesis, based on the design of a 140+90m span unusual single tower and single cable plane cable-stayed bridge, free vibration characteristics and seismic response are investigated; three dimensional finite element models of a single tower cable-stayed bridge with and without the pile-soil-structure interaction are established respectively by utilizing finite element software MIDAS/CIVIL, seismic response of Response spectrum and Earthquake schedule are analyzed respectively and compared. By the comparison of the data analysis, for small stiffness span cable-stayed bridge, the pile-soil-structure interaction can not be ignored with calculation and analysis of seismic response.


2011 ◽  
Vol 261-263 ◽  
pp. 1619-1624
Author(s):  
Pei Zhen Li ◽  
Jing Meng ◽  
Peng Zhao ◽  
Xi Lin Lu

Shaking table test on soil-structure interaction system in harder site condition is presented briefly in this paper. Three-dimensional finite element analysis on shaking table test is carried out using ANSYS program. The surface-to-surface contact element is taken into consideration for the nonlinearity of the state of the interface of the soil-pile and an equivalent linear model is used for soil behavior. By comparing the results of the finite element analysis with the data from shaking table tests, the computational model is validated. Based on the calculation results, the paper gives the seismic responses under the consideration of soil-structure interaction in harder site condition, including acceleration response, contact analysis on soil pile interface and so on.


Sign in / Sign up

Export Citation Format

Share Document