In search of a general picture processing operator

1978 ◽  
Vol 8 (2) ◽  
pp. 155-173 ◽  
Author(s):  
Goesta H. Granlund
Author(s):  
T. A. Welton

Various authors have emphasized the spatial information resident in an electron micrograph taken with adequately coherent radiation. In view of the completion of at least one such instrument, this opportunity is taken to summarize the state of the art of processing such micrographs. We use the usual symbols for the aberration coefficients, and supplement these with £ and 6 for the transverse coherence length and the fractional energy spread respectively. He also assume a weak, biologically interesting sample, with principal interest lying in the molecular skeleton remaining after obvious hydrogen loss and other radiation damage has occurred.


2011 ◽  
Author(s):  
Catherine Reeve ◽  
Heidi Marsh ◽  
Suzanne MacDonald

2015 ◽  
Vol 23 (8) ◽  
pp. 1361
Author(s):  
Songqing LI ◽  
Qingbai ZHAO ◽  
Zhijin ZHOU ◽  
Yi ZHANG

2005 ◽  
Vol 60 (1) ◽  
pp. P49-P56 ◽  
Author(s):  
D. P. Smith ◽  
C. H. Hillman ◽  
A. R. Duley

Nanomaterials ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1527
Author(s):  
Jakob Hinum-Wagner ◽  
David Kuhness ◽  
Gerald Kothleitner ◽  
Robert Winkler ◽  
Harald Plank

High-fidelity 3D printing of nanoscale objects is an increasing relevant but challenging task. Among the few fabrication techniques, focused electron beam induced deposition (FEBID) has demonstrated its high potential due to its direct-write character, nanoscale capabilities in 3D space and a very high design flexibility. A limitation, however, is the low fabrication speed, which often restricts 3D-FEBID for the fabrication of single objects. In this study, we approach that challenge by reducing the substrate temperatures with a homemade Peltier stage and investigate the effects on Pt based 3D deposits in a temperature range of 5–30 °C. The findings reveal a volume growth rate boost up to a factor of 5.6, while the shape fidelity in 3D space is maintained. From a materials point of view, the internal nanogranular composition is practically unaffected down to 10 °C, followed by a slight grain size increase for even lower temperatures. The study is complemented by a comprehensive discussion about the growth mechanism for a more general picture. The combined findings demonstrate that FEBID on low substrate temperatures is not only much faster, but practically free of drawbacks during high fidelity 3D nanofabrication.


1974 ◽  
Vol 3 (2) ◽  
pp. 178-192 ◽  
Author(s):  
Azriel Rosenfeld
Keyword(s):  

2013 ◽  
Vol 50 (7) ◽  
pp. 642-652 ◽  
Author(s):  
Christian Laier ◽  
Frank P. Schulte ◽  
Matthias Brand

2011 ◽  
Vol 1363 ◽  
Author(s):  
G.J. Ackland ◽  
T.P.C. Klaver ◽  
D.J. Hepburn

ABSTRACTFirst principles calculations have given a new insight into the energies of point defects in many different materials, information which cannot be readily obtained from experiment. Most such calculations are done at zero Kelvin, with the assumption that finite temperature effects on defect energies and barriers are small. In some materials, however, the stable crystal structure of interest is mechanically unstable at 0K. In such cases, alternate approaches are needed. Here we present results of first principles calculations of austenitic iron using the VASP code. We determine an appropriate reference state for collinear magnetism to be the antiferromagnetic (001) double-layer (AFM-d) which is both stable and lower in energy than other possible models for the low temperature limit of paramagnetic fcc iron. Another plausible reference state is the antiferromagnetic (001) single layer (AFM-1). We then consider the energetics of dissolving typical alloying impurities (Ni, Cr) in the materials, and their interaction with point defects typical of the irradiated environment. We show that the calculated defect formation energies have fairly high dependence on the reference state chosen: in some cases this is due to instability of the reference state, a problem which does not seem to apply to AFM-d and AFM-1. Furthermore, there is a correlation between local free volume magnetism and energetics. Despite this, a general picture emerge that point defects in austenitic iron have geometries similar to those in simpler, non-magnetic, thermodynamically stable FCC metals. The defect energies are similar to those in BCC iron. The effect of substitutional Ni and Cr on defect properties is weak, rarely more than tenths of eV, so it is unlikely that small amounts of Ni and Cr will have a significant effect on the radiation damage in austenitic iron at high temperatures.


Sign in / Sign up

Export Citation Format

Share Document