Virucidal effect of UV light on hepatitis a virus in sea water: evaluation with cell culture and RT-PCR

1995 ◽  
Vol 31 (5-6) ◽  
1995 ◽  
Vol 31 (5-6) ◽  
pp. 157-160 ◽  
Author(s):  
F. Lévêque ◽  
J. M. Crance ◽  
C. Beril ◽  
L. Schwartzbrod

Virucidal effect of UV light on hepatitis A virus was investigated in artificial sea water. Infectious virus was no longer detectable after 15 min irradiation of 3 liter experimentally contaminated water. Genomic amplification by polymerase chain reaction after reverse transcription allowed the detection of viral RNA in all samples even after 60 min irradiation.


2011 ◽  
Vol 74 (10) ◽  
pp. 1756-1761 ◽  
Author(s):  
JI-YEON HYEON ◽  
JUNG-WHAN CHON ◽  
CHANKYU PARK ◽  
JUNG-BOK LEE ◽  
IN-SOO CHOI ◽  
...  

We have developed a rapid and simple method for filtration using a positively charged membrane to concentrate hepatitis A virus (HAV) from lettuce and an integrated cell culture–real-time reverse transcription PCR (ICC–real-time RT-PCR) to detect infectious HAV. The most suitable buffer for HAV concentration by filtration was 100 mM Tris-HCl, 50 mM glycine (pH 9.5). Filtration using the NanoCeram matrix was compared with polyethylene glycol precipitation for viral concentration from lettuce inoculated with 6 log RNA copies of HAV. The recovery rate of filtration was statistically higher than that of polyethylene glycol precipitation (47.3 versus 24.9%, respectively). The sensitivity of ICC–real-time RT-PCR for detection of infectious HAV was determined by inoculation of FRhK-4 cells with HAV (4 log to 0 log RNA copies). ICC–real-time RT-PCR detected infectious HAV on average 5 days earlier than cytopathic effects at all inoculation levels. HAV recovered from lettuce (approximately 3 log RNA copies) was also analyzed with ICC–real-time RT-PCR. Infectious HAV was detected within 2 days postinfection by ICC–real-time RT-PCR, whereas cytopathic effects were not observed until 7 days postinfection. Coupled with a virus concentration and purification system using a positively charged membrane, ICC–real-time RT-PCR has the potential to become a novel and rapid method for the detection of infectious HAV in vegetables.


2001 ◽  
Vol 47 (2) ◽  
pp. 153-157 ◽  
Author(s):  
Kelly A Reynolds ◽  
Charles P Gerba ◽  
Morteza Abbaszadegan ◽  
Ian L Pepper

This study applied the integrated cell culture/polymerase chain reaction methodology (ICC/PCR) for rapid and specific detection of both cytopathogenic and noncytopathogenic viruses. Results of this study showed that the use of direct RT-PCR or conventional cell culture alone may yield erroneous results with the analysis of environmental samples. The purpose of this study was to compare cultural, molecular, and combined assays for the most effective method of virus detection in variable environmental samples. Using ICC/PCR, stock enterovirus inocula of [Formula: see text]10 PFU were PCR positive in at least 4/5 replicate flasks after only 5 h of incubation in cell culture, and in all flasks after [Formula: see text]10 h. An inoculum of one PFU was detected by PCR after 20 h of cell culture incubation while for concentrations of virus below one PFU, 25 h of incubation was sufficient. Similarly, hepatitis A virus (HAV) inocula of 100 MPN/flask, produced indeterminate CPE in cell culture, but were clearly detected by ICC/PCR following 48 h of incubation. Lower levels of HAV, 1 and 10 MPN, were detected by ICC/PCR after 96 to 72 h of incubation, respectively. Cell culture lysates from 11 environmental sample concentrates of sewage, marine water, and surface drinking water sources, were positive for enteroviruses by ICC/PCR compared to 3 positive by direct RT-PCR alone. Results from ICC/PCR eventually agreed with cell culture but required [Formula: see text]48 h of incubation, compared to as long as 3 weeks for CPE following incubation with BGM and FRhK cells.Key words: RT-PCR, cell culture, ICC/PCR, enterovirus, hepatitis A virus.


2002 ◽  
Vol 68 (10) ◽  
pp. 4951-4955 ◽  
Author(s):  
Jun Wen Li ◽  
Zhong Tao Xin ◽  
Xin Wei Wang ◽  
Jin Lai Zheng ◽  
Fu Huan Chao

ABSTRACT The study was intended to investigate the feasibility of reverse transcription-PCR (RT-PCR) for evaluation of the efficacy of inactivation of viruses in water and to elucidate the mechanisms of inactivation of hepatitis A virus (HAV) by chlorine. Cell culture, enzyme-linked immunosorbent assay, and long-overlap RT-PCR were used to detect the infectivity, antigenicity, and entire genome of HAV inactivated or destroyed by chlorine. The cell culture results revealed the complete inactivation of infectivity after 30 min of exposure to 10 or 20 mg of chlorine per liter and the highest level of sensitivity in the 5′ nontranslated regions (5′NTR), inactivation of which took as much time as the inactivation of infectivity of HAV by chlorine. However, antigenicity was not completely destroyed under these conditions. Some fractions in the coding region were resistant to chlorine. To determine the specific region of the 5′NTR lost, three segments of primers were redesigned to monitor the region from bp 1 to 1023 across the entire genome. It was shown that the sequence from bp 1 to 671 was the region most sensitive to chlorine. The results suggested that the inactivation of HAV by chlorine was due to the loss of the 5′NTR. It is believed that PCR can be used to assess the efficacy of disinfection of HAV by chlorine as well as to research the mechanisms of inactivation of viruses by disinfectants.


1999 ◽  
Vol 65 (2) ◽  
pp. 444-449 ◽  
Author(s):  
Morteza Abbaszadegan ◽  
Peter Stewart ◽  
Mark LeChevallier

ABSTRACT We evaluated the use of the PCR for detection of enteric viruses in groundwater. To do this, we used an improved sample-processing technique and a large-volume amplification protocol. The objective of this study was to use advanced molecular techniques to develop a rapid and simple method which can be used by the water industry for detection of viral contamination in a variety of water samples. The strategy described here fulfills the water industry’s need for a rapid, reliable, easily performed method for analyzing groundwater for virus contamination. Viruses were detected after concentration from at least 400 gallons (1,512 liters) of water by a filter adsorption and elution method, which resulted in a concentrate containing viruses. A total of 150 samples were analyzed by performing cell culture assays for enteroviruses and by performing reverse transcription PCR (RT-PCR) analyses for enteroviruses, hepatitis A virus, and rotavirus. Thirteen samples (8.7%) produced cellular cytopathic effects when the Buffalo green monkey cell line was used. When primers specific for enteroviruses were used in RT-PCR, 40 of 133 samples (30.1%) tested positive for the presence of enterovirus RNA. When hepatitis A virus-specific primers were used, 12 of 139 samples (8.6%) were considered positive for the presence of hepatitis A viral RNA. The RT-PCR analysis performed with rotavirus-specific primers identified 18 of 130 samples (13.8%) that were positive for rotavirus RNA sequences. Our sample-processing technique and large-volume PCR protocol (reaction volume, 300 μl) resulted in sufficient removal or dilution of inhibitors so that more than 95% of the samples could be assayed by PCR. Because of its sensitivity for detecting viral nucleic acid sequences, PCR analysis should produce more positive results than cell culture analysis. Since either cell culture analysis or PCR can reveal only a “snapshot” of the quality of the groundwater being sampled, PCR seems to be a desirable rapid initial screening tool.


1998 ◽  
Vol 64 (2) ◽  
pp. 504-508 ◽  
Author(s):  
N. Jothikumar ◽  
Dean O. Cliver ◽  
Tadesse W. Mariam

ABSTRACT We studied the concentration of hepatitis A virus (HAV) from environmental samples by membrane filter-based urea-arginine phosphate buffer and its detection by using immunomagnetic capture (IC) reverse transcription (RT)-PCR (IC PCR). Magnetic beads coated with anti-HAV rabbit antibodies were used for enrichment and concentration of HAV from environmental samples. IC PCR is sensitive enough to detect as few as 0.04 PFU of cell culture-adapted HAV in inoculated water and sewage samples. IC PCR is specific and does not yield positive reactions with poliovirus 1, HAV RNA, or selected bacteriophages. IC concentrates viruses suspended in small volumes to microliter volumes that can be used directly in RT-PCR. IC concentration of viruses from sewage samples without concentration of inhibitory substances is important for successful RT-PCR detection. In a field trial, 2 of 18 raw sewage samples tested by IC PCR were positive for HAV.


1989 ◽  
Vol 21 (3) ◽  
pp. 255-258 ◽  
Author(s):  
Evangélos Biziagos ◽  
Jacques Passagot ◽  
Jean-Marc Crance ◽  
Robert Deloince

The concentration of cell-culture-adapted hepatitis A virus (HAV) from experimentally contaminated distilled, drinking, waste and seawater was performed by using a filter adsorption-elu-tion method in the following conditions: HAV seeded in water was adsorbed at pH 4.0 to two nitrocellulose membranes (1.2 and 0.45 µm porosity for distilled and tap water or 8.0 and 3.0 µm porosity for waste and seawater), then eluted by 3% beef-extract at pH 8.5 and further concentrated by polyethylene glycol 6000 precipitation. Thus, HAV in 5 to 50 liters of seeded waters was concentrated approximately 1,700 to 17,000 fold with greater than 70% recovery of the initial virus added to the samples.


1981 ◽  
Vol 37 (1) ◽  
pp. 216-225 ◽  
Author(s):  
S A Locarnini ◽  
A G Coulepis ◽  
E G Westaway ◽  
I D Gust

1987 ◽  
Vol 61 (10) ◽  
pp. 3035-3039 ◽  
Author(s):  
J I Cohen ◽  
J R Ticehurst ◽  
S M Feinstone ◽  
B Rosenblum ◽  
R H Purcell

Sign in / Sign up

Export Citation Format

Share Document