In vivo correlation of doppler waveform analysis with arterial input impedance parameters

1993 ◽  
Vol 19 (7) ◽  
pp. 549-559 ◽  
Author(s):  
Gregory J. Downing ◽  
Dev Maulik ◽  
Cara Phillips ◽  
Taha R. Kadado
2019 ◽  
Vol 13 (2) ◽  
pp. 189-191
Author(s):  
Damien Lanéelle ◽  
Olivier Stivalet ◽  
Loukman Omarjee ◽  
Guillaume Mahé

2007 ◽  
Vol 31 (3) ◽  
pp. 149-151 ◽  
Author(s):  
Brian P. Hembling ◽  
Kelley C. Hubler ◽  
Peter M. Richard ◽  
William A. O'Keefe ◽  
Chelsey Husfloen ◽  
...  

A retrospective analysis was performed comparing the effectiveness of ankle brachial index (ABI) to Doppler waveform analysis for the detection of peripheral arterial disease (PAD) in a group of patients with an estimated 31% prevalence of diabetes. A total of 21,199 ankle pressures and corresponding Doppler waveforms were correlated; 8,628, or 41%, of the ankle pressures were within normal limits; 8,335, or 40%, of the ankle pressures were below normal limits; and 4,042, or 19%, of the ankle pressures were noncompressible. Using ABI alone for screening in a population with a high incidence of diabetes is significantly limited because of noncompressible ankle pressures caused by arterial calcification. A total of 19% of the segments evaluated in this population yielded noncompressible vessels. The prevalence of PAD, detected by Doppler waveform analysis in the segments with non-compressible ankle pressures, was 69%. Additional modalities such as Doppler waveform analysis would further increase the accuracy of screening for PAD in this population. Alternately, using the ABI alone for the detection of PAD can be improved by interpreting ABIs greater than 1.2 as positive results because of the high prevalence of PAD in this group.


Blood ◽  
2012 ◽  
Vol 120 (21) ◽  
pp. 3382-3382
Author(s):  
Junka Haku ◽  
Kenichi Ogiwara ◽  
Tomoko Matsumoto ◽  
Koji Yada ◽  
Midori Shima ◽  
...  

Abstract Abstract 3382 There is no optimal assay to monitor the hemostatic effect of bypassing therapy for hemophilia A patients (HA) with inhibitor. Clot waveform analysis (CWA) is a convenient method of assessing global clotting function based on the continuous monitoring of light transmittance or absorbance during routine coagulation tests such as aPTT. We attempted to optimize the aPTT based CWA for hemostatic monitoring during the bypassing therapy in patients of HA with inhibitor. An automated laboratory system, MDA-II® (Trinity Biotech) was used for CWA. Clot waveform was plotted from transmittance change during the clot formation. By the first and second derivation of the waveform, parameters such as clotting time, the maximum velocity (|min1|) and acceleration (|min2|) were calculated. Three trigger reagents were used; [R1] ellagic acid (E) and phospholipid (PL) that is used as an aPTT reagent, [R2] tissue factor (TF, Innovin®) and PL as a 17,000-diluted PT reagent, [R3] the mixed condition of E, TF and PL, based on our recent report on thrombin generation test optimized for HA (Matsumoto, IJH, 2009). Results were expressed as a percentage (% of control) relative to control pooled plasma. The great difference in all parameters between factor (F)VIII-deficient and control plasma resulted in R1>R3>>R2 in order (|min2| in R1, R2, R3 were 13, 119, 21% of control, respectively). Since significant difference between both plasma was not observed, we excluded R2. By the addition of clinically therapeutic concentration of recombinant FVIIa (rFVIIa, NovoSeven®) (25 nM), parameters in R3 were more improved than R1 (|min2| in R1, R3 were 18, 47% of control, respectively). Similar results were observed by the addition of activated prothrombin complex concentrates (APCC, FEIBA®) (1 U/ml) (|min2| in R1, R3 was 32, 71% of control, respectively). According to these in vitro experiments, R3 (E/TF/PL) was regarded as most optimal reagent. Next, in order to confirm the usefulness of the R3-CWA system in vivo, six patients with HA with inhibitor to whom rFVIIa (n=6, 37 (12–59) BU/ml, 105 (91–175) ƒÊg/kg dosage) or APCC (n=3, 25 (12–49) BU/ml, 91 (91–100) U/kg dosage) was administrated, were evaluated. All patients showed the clinical hemostatic efficacy by each bypassing agent. As shown in Table 2 and Fig. 1, the hemostatic effects by bypassing agents were confirmed by improvement in all R3-CWA parameters. APTT based CWA system should be promising method for quantitative monitoring during the bypassing therapy with routine automated clotting machine and only with the modified reagents such as well-balanced mixtures of E, TF and PL. Table 1. Parameters of CWA using three reagents in FVIII-deficient plasma with bypassing agents in vitro Parameter Reagent R1 R2 R3 Clotting time % of control     FVIII-def plasma 372 86 147     +rFVIIa (25 nM) 271 – 100     +APCC (1 U/ml) 122 – 69 |min1| % of control     FVIII-def plasma 16 90 33     +rFVIIa (25 nM) 20 – 54     +APCC (1 U/ml) 27 – 69 |min2| % of control     FVIII-def plasma 13 119 21     +rFVIIa (25 nM) 18 – 47     +APCC (1 U/ml) 32 – 71 Values are shown as median of triplicate. Table 2. Effect of bypassing agents in vivo on parameters of R3-triggered CWA Parameter rFVIIa (n=6) APCC (n=3) Pre Post Pre Post % of control % of control Clotting time 202 103 135 99 (129–268) (91–122) (127–159) (89–104) |min1| 37 56 41 60 (19–48) (40–78) (30–42) (46–75) |min2| 19 53 23 41 (13–32) (44–75) (16–24) (34–60) Values are shown as median (range). Fig. 1 Representative data of R3-triggered CWA in a case of HA with inhibitor on bypassing therapy using rFVIIa (dotted line) or APCC (solid line). Fig. 1. Representative data of R3-triggered CWA in a case of HA with inhibitor on bypassing therapy using rFVIIa (dotted line) or APCC (solid line). Disclosures: Shima: Chugai Pharmaceutical Co., Ltd.: Consultancy, Honoraria, Research Funding.


Sign in / Sign up

Export Citation Format

Share Document