Ventilation Network Analyzer in Fortran IV

2019 ◽  
pp. 415-435
Author(s):  
Joel Carpenter ◽  
Benjamin J. Eggleton ◽  
Jochen Schröder

1996 ◽  
Vol 36 (3) ◽  
pp. 175-180
Author(s):  
L. Barretta ◽  
P. Cremonesi ◽  
E. Panzeri ◽  
N. Scarabottolo

2021 ◽  
Vol 69 (1) ◽  
pp. 874-886
Author(s):  
Alberto Maria Angelotti ◽  
Gian Piero Gibiino ◽  
Troels S. Nielsen ◽  
Dominique Schreurs ◽  
Alberto Santarelli

2021 ◽  
Vol 11 (12) ◽  
pp. 5415
Author(s):  
Aleksandr Gorst ◽  
Kseniya Zavyalova ◽  
Aleksandr Mironchev ◽  
Andrey Zapasnoy ◽  
Andrey Klokov

The article investigates the near-field probe of a special design to account for changes in glucose concentration. The probe is designed in such a way that it emits radiation in both directions from its plane. In this paper, it was proposed to modernize this design and consider the unidirectional emission of the probe in order to maximize the signal and reduce energy loss. We have done extensive research for both bidirectional and unidirectional probe designs. Numerical simulations and field experiments were carried out to determine different concentrations of glucose (0, 4, 5.3, 7.5 mmol/L). Numerical modeling of a unidirectional probe showed that the interaction of radiation generated by such a probe with a multilayer structure simulating a human hand showed a better result and high sensitivity compared to a bidirectional probe. Further, based on the simulation results, a phantom (physical model) of a human hand was recreated from layers with dielectric properties as close as possible to the properties of materials during simulation. The probe was constructed from a copper tube and matched both the geometric and physical parameters of the model. The experimental measurement was carried out using a vector network analyzer in the frequency range 2–10 GHz. The experimental measurement was carried out using a vector network analyzer in the frequency range 2–10 GHz for the unidirectional and bidirectional probes. Further, the results of the experiment were compared with the results of numerical simulation. According to the results of multiple experiments, it was found that the average deviation between the concentrations was 2 dB for a unidirectional probe and 0.4 dB for a bidirectional probe. Thus, the sensitivity of the unidirectional probe was 1.5 dB/(mmol/L) for the bidirectional one 0.3 dB/(mmol/L). Thus, the improved design of the near-field probe can be used to record glucose concentrations.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4743
Author(s):  
Tomasz Janoszek ◽  
Zbigniew Lubosik ◽  
Lucjan Świerczek ◽  
Andrzej Walentek ◽  
Jerzy Jaroszewicz

The paper presents the results of experimental and model tests of transport of dispersed fluid droplets forming a cloud of aerosol in a stream of air ventilating a selected section of the underground excavation. The excavation selected for testing is part of the ventilation network of the Experimental Mine Barbara of the Central Mining Institute. For given environmental conditions, such as temperature, pressure, relative humidity, and velocity of air, the distribution of aerosol droplet changes in the mixture of air and water vapor along the excavation at a distance was measured at 10 m, 25 m, and 50 m from the source of its emission. The source of aerosol emission in the excavation space was a water nozzle that was located 25 m from the inlet (inlet) of the excavation. The obtained results of in situ tests were related to the results of numerical calculations using computational fluid dynamics (CFD). Numerical calculations were performed using Ansys-Fluent and Ansys-CFX software. The dimensions and geometry of the excavation under investigation are presented. The authors describe the adopted assumptions and conditions for the numerical model and discuss the results of the numerical solution.


Frequenz ◽  
2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Maksud Alam ◽  
Amber Khan ◽  
Mainuddin ◽  
Binod Kumar Kanaujia ◽  
Mirza Tariq Beg

AbstractIn this paper a coplanar waveguide feed (CPW) monopole antenna backed with artificial magnetic conductor (AMC) structure for efficient radiation has been presented for off-body wearable applications. A split ring resonator (SRR) having thiner and longer lines to produce higher inductance and six splits with smaller gaps for high capacitance have been placed underneath CPW fed monopole to achieve resonance mode at a lower frequency. Higher values of inductance and capacitance produce resonant modes at relatively lower frequencies resulting in highly miniaturized antenna. The desired −10dB S11 bandwidth has been optimized firstly, by tuning/optimizing flow of surface currents with the help of several slots/slits and later by realizing AMC reflector with the help of full ground backed foam. The proposed antenna covers 2.45 GHz industrial, scientific and medical (ISM) band body area network (BAN) application and posses good front to back ratio (FBR) and thereby low and acceptable values of specific absorption rate (SAR). The proposed antenna has been designed and simulated using Ansys high frequency structured simulator and tested using vector network analyzer and anechoic chamber. The simulated and measured results well agree with each other.


Sign in / Sign up

Export Citation Format

Share Document