CALCULATION ANALYSIS ON POWER SYSTEM DAMPING AND LOW-FREQUENCY ELECTROMECHANICAL OSCILLATIONS IN INTERCONNECTED POWER SYSTEMS

Author(s):  
Zhou Xiao Xin ◽  
He Zhi Hua ◽  
Zhang Zu Ping
2021 ◽  
pp. 22-30
Author(s):  
Kahramon R. ALLAEV ◽  
◽  
Tokhir F. MAKHMUDOV ◽  

Power systems are large non-linear systems that are often subject to low frequency electromechanical oscillations with a frequency of 0.5–2.5 Hz. Power system stabilizers (PSS) are commonly used as effective and economically efficient means to dampen electromechanical oscillations of generators and increase the stability of power systems. PSS can increase the power transmission stability limits by adding a stabilizing signal through the channels of the automatic excitation control system. The article presents the results of training a neural network based on which a fuzzy logic PSS is obtained for increasing the stability of electric power systems. The synchronous generator rotor speed deviation and acceleration were taken as input data for the fuzzy logic controller. These variables have a significant effect on damping the rotor's electromechanical oscillations. The characteristics of the power system equipped with the proposed fuzzy logic based PSS are compared with its characteristics with a PSS with non-optimized parameters and without a PSS.


Mathematics ◽  
2021 ◽  
Vol 9 (13) ◽  
pp. 1474
Author(s):  
Ruben Tapia-Olvera ◽  
Francisco Beltran-Carbajal ◽  
Antonio Valderrabano-Gonzalez ◽  
Omar Aguilar-Mejia

This proposal is aimed to overcome the problem that arises when diverse regulation devices and controlling strategies are involved in electric power systems regulation design. When new devices are included in electric power system after the topology and regulation goals were defined, a new design stage is generally needed to obtain the desired outputs. Moreover, if the initial design is based on a linearized model around an equilibrium point, the new conditions might degrade the whole performance of the system. Our proposal demonstrates that the power system performance can be guaranteed with one design stage when an adequate adaptive scheme is updating some critic controllers’ gains. For large-scale power systems, this feature is illustrated with the use of time domain simulations, showing the dynamic behavior of the significant variables. The transient response is enhanced in terms of maximum overshoot and settling time. This is demonstrated using the deviation between the behavior of some important variables with StatCom, but without or with PSS. A B-Spline neural networks algorithm is used to define the best controllers’ gains to efficiently attenuate low frequency oscillations when a short circuit event is presented. This strategy avoids the parameters and power system model dependency; only a dataset of typical variable measurements is required to achieve the expected behavior. The inclusion of PSS and StatCom with positive interaction, enhances the dynamic performance of the system while illustrating the ability of the strategy in adding different controllers in only one design stage.


2013 ◽  
Vol 391 ◽  
pp. 271-276
Author(s):  
Peng Li ◽  
Ning Bo Wang ◽  
De Zhi Chen ◽  
Xiao Rong Zhu ◽  
Yun Ting Song

Increasing penetration level of wind power integration has a significant impact on low-frequency oscillations of power systems. Based on PSD-BPA simulation software, time domain simulation analysis and eigenvalue analysis are employed to investigate its effect on power system low-frequency oscillation characteristic in an outward transmitting thermal generated power bundled with wind power illustrative power system. System damping enhances markedly and the risk of low-frequency oscillation reduce when the generation of wind farm increase. In addition, dynamic reactive power compensations apply to wind farm, and the simulation result indicates that it can improve dynamic stability and enhance the system damping.


2011 ◽  
Vol 26 (3) ◽  
pp. 1733-1743 ◽  
Author(s):  
José L. Rueda ◽  
Carlos A. Juarez ◽  
István Erlich

2014 ◽  
Vol 63 (2) ◽  
pp. 161-175 ◽  
Author(s):  
S. Selvakumaran ◽  
V. Rajasekaran ◽  
R. Karthigaivel

Abstract A new design of decentralized Load Frequency Controller for interconnected thermal non-reheat power systems with AC-DC parallel tie-lines based on Genetic Algorithm (GA) tuned Integral and Proportional (IP) controller is proposed in this paper. A HVDC link is connected in parallel with an existing AC tie-line to stabilize the frequency oscillations of the AC tie-line system. Any optimum controller selected for load frequency control of interconnected power systems should not only stabilize the power system but also reduce the system frequency and tie line power oscillations and settling time of the output responses. In practice Load Frequency Control (LFC) systems use simple Proportional Integral (PI) or Integral (I) controller. The controller parameters are usually tuned based on classical or trial-and-error approaches. But they are incapable of obtaining good dynamic performance for various load change scenarios in multi-area power system. For this reason, in this paper GA tuned IP controller is used. A two area interconnected thermal non-reheat power system is considered to demonstrate the validity of the proposed controller. The simulation results show that the proposed controller provides better dynamic responses with minimal frequency and tie-line power deviations, quick settling time and guarantees closed-loop stability margin.


Sign in / Sign up

Export Citation Format

Share Document