ATTENUATION COEFFICIENTS OF VARIOUS ELEMENTS

Kerntechnik ◽  
2017 ◽  
Vol 82 (3) ◽  
pp. 339-343 ◽  
Author(s):  
S. M. Vahabi ◽  
M. Bahreinipour ◽  
M. Shamsaie-Zafarghandi

Materials ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 3913
Author(s):  
Aljawhara H. Almuqrin ◽  
Mohamed Hanfi ◽  
K. G. Mahmoud ◽  
M. I. Sayyed ◽  
Hanan Al-Ghamdi ◽  
...  

The radiation shielding competence was examined for a binary glass system xLa2O3 + (1 − x) TeO2 where x = 5, 7, 10, 15, and 20 mol% using MCNP-5 code. The linear attenuation coefficients (LACs) of the glasses were evaluated, and it was found that LT20 glass has the greatest LAC, while LT5 had the least LAC. The transmission factor (TF) of the glasses was evaluated against thicknesses at various selected energies and was observed to greatly decrease with increasing thickness; for example, at 1.332 MeV, the TF of the LT5 glass decreased from 0.76 to 0.25 as the thickness increased from 1 to 5 cm. The equivalent atomic number (Zeq) of the glasses gradually increased with increasing photon energy above 0.1 MeV, with the maximum values observed at around 1 MeV. The buildup factors were determined to evaluate the accumulation of photon flux, and it was found that the maximum values for both can be seen at around 0.8 MeV. This research concluded that LT20 has the greatest potential in radiation shielding applications out of the investigated glasses due to the glass having the most desirable parameters.


Water ◽  
2021 ◽  
Vol 13 (11) ◽  
pp. 1464
Author(s):  
Leon Katona ◽  
Yvonne Vadeboncoeur ◽  
Christopher T. Nietch ◽  
Katie Hossler

Recent studies suggest that photophysiological parameters for intact substrates with depth (e.g., periphytic biofilms, microphytobenthos) are overestimated by pulse-amplitude modulated (PAM) fluorometry. This overestimation results from depth-integration effects, following the activation of deeper photosynthesizing layers by an attenuated light signal. To mitigate this error, we propose a novel slide-based thin-film technique in which fluorescence is measured on a vertically representative subsample of the biofilm, spread evenly on a microscope slide. We compared bias and precision for photosynthetic parameters estimated through conventional PAM fluorometry on intact biofilms and through our novel slide-based technique, both theoretically and empirically. Numerical simulations confirmed the consistent overestimation of key parameters for intact biofilms, with relative errors up to 145%, compared to, at most, 52% on thin films. Paired empirical observations likewise demonstrated that estimates based on intact biofilms were consistently higher (up to 248%, p<0.001) than estimates from thin films. Numerical simulation suggested greater precision with the slide-based technique for homogeneous biofilms, but potentially less precision for heterogeneous biofilms with improper subsampling. Our empirical comparison, however, demonstrated some improvement in precision with the slide-based technique (e.g., the coefficient of variation for the maximum electron transport rate was reduced 30%, p=0.009). We recommend the use of the slide-based technique, particularly for biofilms that are thick or have small light attenuation coefficients. Care should be taken, however, to obtain vertically representative subsamples of the biofilm for measurement.


2010 ◽  
Vol 37 (7) ◽  
pp. 910-914 ◽  
Author(s):  
I. Akkurt ◽  
H. Akyıldırım ◽  
B. Mavi ◽  
S. Kilincarslan ◽  
C. Basyigit

Sign in / Sign up

Export Citation Format

Share Document