Air Concentration Distributions in Water Jets Discharging Into the Atmosphere

Keyword(s):  
Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 492
Author(s):  
Fatih Selimefendigil ◽  
Hakan F. Oztop ◽  
Mikhail A. Sheremet

In this study, thermoelectric generation with impinging hot and cold nanofluid jets is considered with computational fluid dynamics by using the finite element method. Highly conductive CNT particles are used in the water jets. Impacts of the Reynolds number of nanojet stream combinations (between (Re1, Re2) = (250, 250) to (1000, 1000)), horizontal distance of the jet inlet from the thermoelectric device (between (r1, r2) = (−0.25, −0.25) to (1.5, 1.5)), impinging jet inlet to target surfaces (between w2 and 4w2) and solid nanoparticle volume fraction (between 0 and 2%) on the interface temperature variations, thermoelectric output power generation and conversion efficiencies are numerically assessed. Higher powers and efficiencies are achieved when the jet stream Reynolds numbers and nanoparticle volume fractions are increased. Generated power and efficiency enhancements 81.5% and 23.8% when lowest and highest Reynolds number combinations are compared. However, the power enhancement with nanojets using highly conductive CNT particles is 14% at the highest solid volume fractions as compared to pure water jet. Impacts of horizontal location of jet inlets affect the power generation and conversion efficiency and 43% variation in the generated power is achieved. Lower values of distances between the jet inlets to the target surface resulted in higher power generation while an optimum value for the highest efficiency is obtained at location zh = 2.5ws. There is 18% enhancement in the conversion efficiency when distances at zh = ws and zh = 2.5ws are compared. Finally, polynomial type regression models are obtained for estimation of generated power and conversion efficiencies for water-jets and nanojets considering various values of jet Reynolds numbers. Accurate predictions are obtained with this modeling approach and it is helpful in assisting the high fidelity computational fluid dynamics simulations results.


2007 ◽  
Vol 19 (5) ◽  
pp. 053102 ◽  
Author(s):  
Tomiichi Hasegawa ◽  
Hiroshi Watanabe ◽  
Takashi Sato ◽  
Tohru Watanabe ◽  
Masanao Takahashi ◽  
...  
Keyword(s):  

2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Bo Cao ◽  
Junxiao Zheng ◽  
Yixue Chen

Atmospheric dispersion modeling and radiation dose calculations have been performed for a hypothetical AP1000 SGTR accident by HotSpot code 3.03. TEDE, the respiratory time-integrated air concentration, and the ground deposition are calculated for various atmospheric stability classes, Pasquill stability categories A–F with site-specific averaged meteorological conditions. The results indicate that the maximum plume centerline ground deposition value of1.2E+2 kBq/m2occurred at about 1.4 km and the maximum TEDE value of1.41E-05 Sv occurred at 1.4 km from the reactor. It is still far below the annual regulatory limits of 1 mSv for the public as set in IAEA Safety Report Series number 115. The released radionuclides might be transported to long distances but will not have any harmful effect on the public.


2008 ◽  
Vol 134 (6) ◽  
pp. 833-842 ◽  
Author(s):  
Iran E. Lima Neto ◽  
David Z. Zhu ◽  
Nallamuthu Rajaratnam
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document