Effects of aging on the secretory apparatus in the right atrial cardiomyocytes of rats

2020 ◽  
Vol 122 (6) ◽  
pp. 151579
Author(s):  
Marcelo Simoni Ferro ◽  
Marcelo Betti Mascaro ◽  
Romeu Rodrigues De Souza
Clinics ◽  
2014 ◽  
Vol 69 (8) ◽  
pp. 554-558 ◽  
Author(s):  
RR de Souza ◽  
VC de Oliveira ◽  
TC Curi ◽  
DC Maldonado

2019 ◽  
Vol 41 (3) ◽  
pp. 331-337
Author(s):  
Romeu Rodrigues de Souza ◽  
Cristiano Ferreira Pacheco ◽  
Erico Chagas Caperuto ◽  
Laura B.M. Maifrino ◽  
Eliane F. Gama

2005 ◽  
Vol 8 (2) ◽  
pp. 96 ◽  
Author(s):  
Osman Tansel Dar�in ◽  
Alper Sami Kunt ◽  
Mehmet Halit Andac

Background: Although various synthetic materials and pericardium have been used for atrial septal defect (ASD) closure, investigators are continuing to search for an ideal material for this procedure. We report and evaluate a case in which autologous right atrial wall tissue was used for ASD closure. Case: In this case, we closed a secundum ASD of a 22-year-old woman who also had right atrial enlargement due to the defect. After establishing standard bicaval cannulation and total cardiopulmonary bypass, we opened the right atrium with an oblique incision in a superior position to a standard incision. After examining the secundum ASD, we created a flap on the inferior rim of the atrial wall. A stay suture was stitched between the tip of the flap and the superior rim of the defect, and suturing was continued in a clockwise direction thereafter. Considering the size and shape of the defect, we incised the inferior attachment of the flap, and suturing was completed. Remnants of the flap on the inferior rim were resected, and the right atrium was closed in a similar fashion. Results: During an echocardiographic examination, neither a residual shunt nor perigraft thrombosis was seen on the interatrial septum. The patient was discharged with complete recovery. Conclusion: Autologous right atrial patch is an ideal material for ASD closure, especially in patients having a large right atrium. A complete coaptation was achieved because of the muscular nature of the right atrial tissue and its thickness, which is a closer match to the atrial septum than other materials.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Smoczynska ◽  
H.D.M Beekman ◽  
R.W Chui ◽  
S Rajamani ◽  
M.A Vos

Abstract Background Atrial fibrillation (AF) is the most common cardiac arrhythmia treated in clinical practice. Structural remodeling is characterized by atrial enlargement and contributes to the therapeutic resistance in patients with long-standing AF. Purpose To study the atrial arrhythmogenic and echocardiographic consequences induced by volume overload in the complete chronic atrioventricular block (CAVB) dog. Methods Echocardiographic and electrophysiological data was obtained in 14 anaesthetized Mongrel dogs, in acute AV-block (AAVB), after 6 weeks of CAVB (CAVB6) and CAVB10. Left atrial (LA) volume was determined with 2D echocardiography by using the biplane method. An electrocardiogram and monophasic action potentials (MAP) at the right atrial (RA) free wall were recorded. Atrial effective refractory period (AERP) was determined by continuous programmed electrical stimulation (PES) of 20 beats with a cycle length of 400 ms and an extrastimulus with decremental design until refractoriness was reached. A continuous PES protocol of 20 beats with an extrastimulus 5 ms longer than the AERP was applied for 150 seconds to trigger AF. After 5 min without arrhythmias, autonomic neuromodulation was performed by intravenous infusion (IV) of acetylcholine (1,5μg/kg/min to 6,0μg/kg/min) for 20 min followed by prompt IV infusion of isoprenaline (3μg/min) until the atrial heart rate increased by 20 bpm. PES with an extrastimulus was repeated for 150 seconds to induce AF. Results LA volume increased from 13.7±3.2 ml at AAVB to 20.5±5.9 ml* at CAVB6, and 22.7±6.0 ml* at CAVB10 (Fig. 1A). AERP was similar at AAVB, CAVB6, and CAVB10 (115.8±11.9, 117.3±11.7, and 106.8±12.1 ms respectively). Repetitive AF paroxysms of >10 seconds were induced in 1/14 (7%) dogs at AAVB, 1/11 (9%) at CAVB6, and 5/10 (50%)* at CAVB10 (*p<0.05) upon PES (Fig. 1B). Combined neuromodulation and PES did not increase the AF inducibility rate, but prolonged the longest episode of AF in the inducible dogs from 55±49 seconds to 236±202 seconds* at CAVB10 (Fig. 1C). LA volume was higher in inducible dogs 25.0±4.9 ml compared to 18.4±4.2 ml in non-inducible dogs at CAVB10. Conclusion Sustained atrial dilation forms a substrate for repetitive paroxysms of AF. Neuro-modulation prolongs AF episode duration in susceptible dogs. This animal model can be used to study structural remodeling of the atria and possible therapeutic advances in the management of AF. Figure 1 Funding Acknowledgement Type of funding source: Private company. Main funding source(s): Amgen Research


2020 ◽  
pp. 1-2
Author(s):  
Uma Devi Karuru ◽  
Saurabh Kumar Gupta

Abstract It is not uncommon to have prolapse of the atrial septal occluder device despite accurate measurement of atrial septal defect and an appropriately chosen device. This is particularly a problem in cases with large atrial septal defect with absent aortic rim. Various techniques have been described for successful implantation of atrial septal occluder in such a scenario. The essence of all these techniques is to prevent prolapse of the left atrial disc through the defect while the right atrial disc is being deployed. In this brief report, we illustrate the use of cobra head deformity of the device to successfully deploy the device across the atrial septum.


2020 ◽  
Vol 46 (08) ◽  
pp. 895-907
Author(s):  
Nina D. Anfinogenova ◽  
Oksana Y. Vasiltseva ◽  
Alexander V. Vrublevsky ◽  
Irina N. Vorozhtsova ◽  
Sergey V. Popov ◽  
...  

AbstractPrompt diagnosis of pulmonary embolism (PE) remains challenging, which often results in a delayed or inappropriate treatment of this life-threatening condition. Mobile thrombus in the right cardiac chambers is a neglected cause of PE. It poses an immediate risk to life and is associated with an unfavorable outcome and high mortality. Thrombus residing in the right atrial appendage (RAA) is an underestimated cause of PE, especially in patients with atrial fibrillation. This article reviews achievements and challenges of detection and management of the right atrial thrombus with emphasis on RAA thrombus. The capabilities of transthoracic and transesophageal echocardiography and advantages of three-dimensional and two-dimensional echocardiography are reviewed. Strengths of cardiac magnetic resonance imaging (CMR), computed tomography, and cardiac ventriculography are summarized. We suggest that a targeted search for RAA thrombus is necessary in high-risk patients with PE and atrial fibrillation using transesophageal echocardiography and/or CMR when available independently on the duration of the disease. High-risk patients may also benefit from transthoracic echocardiography with right parasternal approach. The examination of high-risk patients should involve compression ultrasonography of lower extremity veins along with the above-mentioned technologies. Algorithms for RAA thrombus risk assessment and protocols aimed at identification of patients with RAA thrombosis, who will potentially benefit from treatment, are warranted. The development of treatment protocols specific for the diverse populations of patients with right cardiac thrombosis is important.


2020 ◽  
Vol 21 (Supplement_1) ◽  
Author(s):  
S Akhunova ◽  
R Khayrullin ◽  
N Stekolshchikova ◽  
M Samigullin ◽  
V Padiryakov

Abstract A 68-year-old man was admitted to the hospital with complaints of pain in the lumbar spine. He had L5 disc herniation, Spinal stenosis of the L5 root canal - S1 on the right in the past medical history. Percutaneous vertebroplasty at the level of L3 and Th8 vertebral bodies was performed six months ago due to painful vertebral hemangioma. The man is suffering from arterial hypertension, receives antihypertensive therapy. During routine transthoracic echocardiography, a hyperechoic structure with a size of 9.5 x 0.9 cm was found in the right atrium and right ventricle. Chest computed tomography with contrast enhancement revealed signs of bone cement in the right atrium and right ventricle, in the right upper lobe artery, in the branches of the upper lobe artery, in the paravertebral venous plexuses. Considering the duration of the disease, the stable condition, the absence of clinical manifestations and disorders of intracardiac hemodynamics, it was decided to refrain from surgical treatment. Antiplatelet therapy and dynamic observation were recommended. Conclusion Percutaneous vertebroplasty is a modern minimally invasive surgical procedure for the treatment of degenerative-dystrophic diseases of the spine. However, the cement can penetrate into the paravertebral veins and migrate to the right chambers of the heart and the pulmonary artery. This clinical case demonstrates asymptomatic cement embolism of the right chambers of the heart and pulmonary artery after percutaneous vertebroplasty, detected incidentally during routine echocardiography. Abstract P686 Figure.


1995 ◽  
Vol 268 (6) ◽  
pp. R1411-R1417
Author(s):  
D. Javeshghani ◽  
S. Mukaddam-Daher ◽  
L. Fan ◽  
Z. Guan ◽  
J. Gutkowska ◽  
...  

Previous studies of the atrial stretch-atrial natriuretic factor (ANF) relationship during pregnancy have employed volume expansion and measured only right atrial pressure (RAP). Consequently, we studied nonpregnant (n = 7) and 115- to 125-day pregnant (n = 7) sheep and assessed the ANF response to changes of RAP and left atrial pressure (LAP) induced by graded balloon inflation. Ewes prepared with vascular catheters and atrial balloons were studied after recovery from preparatory surgical procedures. The basal levels of mean arterial pressure (MAP, 83 +/- 3 mmHg), RAP (2.1 +/- 0.7 mmHg), LAP (4.7 +/- 0.9 mmHg), and heart rate (HR, 102 +/- 6 beats/min) were similar in nonpregnant and pregnant sheep. Pregnancy also resulted in elevation of ANF concentration from 25 +/- 6 to 57 +/- 4 fmol/ml. With right atrial distension, the RAP-ANF relationships were similar in both nonpregnant and pregnant sheep, with a 10-mmHg increase in RAP increasing ANF by an average of 95 +/- 9 fmol/ml. In nonpregnant sheep, the LAP-ANF relationship was more responsive than RAP-ANF because a 10-mmHg increase in LAP resulted in a 193 +/- 10 fmol/ml increase in ANF. Moreover, during pregnancy, the LAP-ANF relationship was significantly more sensitive because a 10-mmHg increase in LAP resulted in a 433 +/- 15 fmol/ml elevation of ANF. These data demonstrate that plasma ANF levels are more responsive to distension of the left atria than to the right. More importantly, the ANF response to left, but not right, atrial distension is enhanced by pregnancy.


Sign in / Sign up

Export Citation Format

Share Document