scholarly journals Effects of ovariectomy on the secretory apparatus in the right atrial cardiomyocytes of middle-aged mice

Clinics ◽  
2014 ◽  
Vol 69 (8) ◽  
pp. 554-558 ◽  
Author(s):  
RR de Souza ◽  
VC de Oliveira ◽  
TC Curi ◽  
DC Maldonado
2020 ◽  
Vol 122 (6) ◽  
pp. 151579
Author(s):  
Marcelo Simoni Ferro ◽  
Marcelo Betti Mascaro ◽  
Romeu Rodrigues De Souza

2019 ◽  
Vol 41 (3) ◽  
pp. 331-337
Author(s):  
Romeu Rodrigues de Souza ◽  
Cristiano Ferreira Pacheco ◽  
Erico Chagas Caperuto ◽  
Laura B.M. Maifrino ◽  
Eliane F. Gama

2005 ◽  
Vol 8 (2) ◽  
pp. 96 ◽  
Author(s):  
Osman Tansel Dar�in ◽  
Alper Sami Kunt ◽  
Mehmet Halit Andac

Background: Although various synthetic materials and pericardium have been used for atrial septal defect (ASD) closure, investigators are continuing to search for an ideal material for this procedure. We report and evaluate a case in which autologous right atrial wall tissue was used for ASD closure. Case: In this case, we closed a secundum ASD of a 22-year-old woman who also had right atrial enlargement due to the defect. After establishing standard bicaval cannulation and total cardiopulmonary bypass, we opened the right atrium with an oblique incision in a superior position to a standard incision. After examining the secundum ASD, we created a flap on the inferior rim of the atrial wall. A stay suture was stitched between the tip of the flap and the superior rim of the defect, and suturing was continued in a clockwise direction thereafter. Considering the size and shape of the defect, we incised the inferior attachment of the flap, and suturing was completed. Remnants of the flap on the inferior rim were resected, and the right atrium was closed in a similar fashion. Results: During an echocardiographic examination, neither a residual shunt nor perigraft thrombosis was seen on the interatrial septum. The patient was discharged with complete recovery. Conclusion: Autologous right atrial patch is an ideal material for ASD closure, especially in patients having a large right atrium. A complete coaptation was achieved because of the muscular nature of the right atrial tissue and its thickness, which is a closer match to the atrial septum than other materials.


2018 ◽  
Vol 1 (94) ◽  
pp. 55-61
Author(s):  
R.O. Myalkovsky

Goal. The purpose of the research was to determine the influence of meteorological factors on potato yield in the conditions of the Right Bank Forest-steppe of Ukraine. Methods.Field, analytical and statistical. Results.It was established that among the mid-range varieties Divo stands out with a yield of 42.3 t/ha, Malin white – 39.8 t/ha, and Legend – 37.1 t/ ha. The most favourable weather and climatic conditions for the production of potato tubers were for the Divo 2011 variety with a yield of 45.9 t/ha and 2013 – 45.1 t/ha. For the Legenda variety 2016, the yield of potato tubers is 40.6 t/ha and 2017 – 43.2 t/ha. Malin White 2013 is 41.4 t/ha and 2017 42.1 t/ha. The average varieties of potatoes showed a slightly lower yield on average over the years of research. However, among the varieties is allocated Nadiyna – 40.3 t/ha, Slovyanka – 37.2 t/ ha and Vera 33.8 t/ha. Among the years, the most high-yielding for the Vera variety was 2016 with a yield of 36.6 t/ha and 2017 year – 37.8 t/ha. Varieties Slovyanka and Nadiyna 2011 and 2012 with yields of 42.6 and 44.3 t/ha and 46.5 and 45.3 t/ha, respectively. Characterizing the yield of potato tubers of medium-late varieties over the years of research, there was a decrease in this indicator compared with medium-early and middle-aged varieties. However, the high yield of the varieties of Dar is allocated – 40.0 t/ha, Alladin – 33.6 t/ha and Oxamit 31.3 t/ha. Among the years, the most favourable ones were: for Oxamit and Alladin – 2011 – 33.5 and 36.5 t/ha, and 2017 – 34.1 and 36.4 t/ha, respectively. Favourable years for harvesting varieties were 2011 and 2012 with yields of 45.7 and 45.8 t/ha. Thus, the highest yield of potato tubers on average over the years of studies of medium-early varieties of 41.2-43.3 t / ha were provided by weather conditions of 2011 and 2017 years, medium-ripe varieties 41.0-41.1 - 2012 and 2011, medium- late 37,6-38,5 t / ha - 2012 and 2011, respectively.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Smoczynska ◽  
H.D.M Beekman ◽  
R.W Chui ◽  
S Rajamani ◽  
M.A Vos

Abstract Background Atrial fibrillation (AF) is the most common cardiac arrhythmia treated in clinical practice. Structural remodeling is characterized by atrial enlargement and contributes to the therapeutic resistance in patients with long-standing AF. Purpose To study the atrial arrhythmogenic and echocardiographic consequences induced by volume overload in the complete chronic atrioventricular block (CAVB) dog. Methods Echocardiographic and electrophysiological data was obtained in 14 anaesthetized Mongrel dogs, in acute AV-block (AAVB), after 6 weeks of CAVB (CAVB6) and CAVB10. Left atrial (LA) volume was determined with 2D echocardiography by using the biplane method. An electrocardiogram and monophasic action potentials (MAP) at the right atrial (RA) free wall were recorded. Atrial effective refractory period (AERP) was determined by continuous programmed electrical stimulation (PES) of 20 beats with a cycle length of 400 ms and an extrastimulus with decremental design until refractoriness was reached. A continuous PES protocol of 20 beats with an extrastimulus 5 ms longer than the AERP was applied for 150 seconds to trigger AF. After 5 min without arrhythmias, autonomic neuromodulation was performed by intravenous infusion (IV) of acetylcholine (1,5μg/kg/min to 6,0μg/kg/min) for 20 min followed by prompt IV infusion of isoprenaline (3μg/min) until the atrial heart rate increased by 20 bpm. PES with an extrastimulus was repeated for 150 seconds to induce AF. Results LA volume increased from 13.7±3.2 ml at AAVB to 20.5±5.9 ml* at CAVB6, and 22.7±6.0 ml* at CAVB10 (Fig. 1A). AERP was similar at AAVB, CAVB6, and CAVB10 (115.8±11.9, 117.3±11.7, and 106.8±12.1 ms respectively). Repetitive AF paroxysms of >10 seconds were induced in 1/14 (7%) dogs at AAVB, 1/11 (9%) at CAVB6, and 5/10 (50%)* at CAVB10 (*p<0.05) upon PES (Fig. 1B). Combined neuromodulation and PES did not increase the AF inducibility rate, but prolonged the longest episode of AF in the inducible dogs from 55±49 seconds to 236±202 seconds* at CAVB10 (Fig. 1C). LA volume was higher in inducible dogs 25.0±4.9 ml compared to 18.4±4.2 ml in non-inducible dogs at CAVB10. Conclusion Sustained atrial dilation forms a substrate for repetitive paroxysms of AF. Neuro-modulation prolongs AF episode duration in susceptible dogs. This animal model can be used to study structural remodeling of the atria and possible therapeutic advances in the management of AF. Figure 1 Funding Acknowledgement Type of funding source: Private company. Main funding source(s): Amgen Research


Nutrients ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 2533
Author(s):  
Zeyu Zhou ◽  
Jocelyn Vidales ◽  
José A González-Reyes ◽  
Bradley Shibata ◽  
Keith Baar ◽  
...  

Alterations in markers of mitochondrial content with ketogenic diets (KD) have been reported in tissues of rodents, but morphological quantification of mitochondrial mass using transmission electron microscopy (TEM), the gold standard for mitochondrial quantification, is needed to further validate these findings and look at specific regions of interest within a tissue. In this study, red gastrocnemius muscle, the prefrontal cortex, the hippocampus, and the liver left lobe were used to investigate the impact of a 1-month KD on mitochondrial content in healthy middle-aged mice. The results showed that in red gastrocnemius muscle, the fractional area of both subsarcolemmal (SSM) and intermyofibrillar (IMM) mitochondria was increased, and this was driven by an increase in the number of mitochondria. Mitochondrial fractional area or number was not altered in the liver, prefrontal cortex, or hippocampus following 1 month of a KD. These results demonstrate tissue-specific changes in mitochondrial mass with a short-term KD and highlight the need to study different muscle groups or tissue regions with TEM to thoroughly determine the effects of a KD on mitochondrial mass.


2020 ◽  
pp. 1-2
Author(s):  
Uma Devi Karuru ◽  
Saurabh Kumar Gupta

Abstract It is not uncommon to have prolapse of the atrial septal occluder device despite accurate measurement of atrial septal defect and an appropriately chosen device. This is particularly a problem in cases with large atrial septal defect with absent aortic rim. Various techniques have been described for successful implantation of atrial septal occluder in such a scenario. The essence of all these techniques is to prevent prolapse of the left atrial disc through the defect while the right atrial disc is being deployed. In this brief report, we illustrate the use of cobra head deformity of the device to successfully deploy the device across the atrial septum.


2020 ◽  
Vol 46 (08) ◽  
pp. 895-907
Author(s):  
Nina D. Anfinogenova ◽  
Oksana Y. Vasiltseva ◽  
Alexander V. Vrublevsky ◽  
Irina N. Vorozhtsova ◽  
Sergey V. Popov ◽  
...  

AbstractPrompt diagnosis of pulmonary embolism (PE) remains challenging, which often results in a delayed or inappropriate treatment of this life-threatening condition. Mobile thrombus in the right cardiac chambers is a neglected cause of PE. It poses an immediate risk to life and is associated with an unfavorable outcome and high mortality. Thrombus residing in the right atrial appendage (RAA) is an underestimated cause of PE, especially in patients with atrial fibrillation. This article reviews achievements and challenges of detection and management of the right atrial thrombus with emphasis on RAA thrombus. The capabilities of transthoracic and transesophageal echocardiography and advantages of three-dimensional and two-dimensional echocardiography are reviewed. Strengths of cardiac magnetic resonance imaging (CMR), computed tomography, and cardiac ventriculography are summarized. We suggest that a targeted search for RAA thrombus is necessary in high-risk patients with PE and atrial fibrillation using transesophageal echocardiography and/or CMR when available independently on the duration of the disease. High-risk patients may also benefit from transthoracic echocardiography with right parasternal approach. The examination of high-risk patients should involve compression ultrasonography of lower extremity veins along with the above-mentioned technologies. Algorithms for RAA thrombus risk assessment and protocols aimed at identification of patients with RAA thrombosis, who will potentially benefit from treatment, are warranted. The development of treatment protocols specific for the diverse populations of patients with right cardiac thrombosis is important.


2021 ◽  
pp. 113269
Author(s):  
Gaurav Singhal ◽  
Magdalene C. Jawahar ◽  
Julie Morgan ◽  
Frances Corrigan ◽  
Emily J. Jaehne ◽  
...  

2020 ◽  
Vol 21 (Supplement_1) ◽  
Author(s):  
S Akhunova ◽  
R Khayrullin ◽  
N Stekolshchikova ◽  
M Samigullin ◽  
V Padiryakov

Abstract A 68-year-old man was admitted to the hospital with complaints of pain in the lumbar spine. He had L5 disc herniation, Spinal stenosis of the L5 root canal - S1 on the right in the past medical history. Percutaneous vertebroplasty at the level of L3 and Th8 vertebral bodies was performed six months ago due to painful vertebral hemangioma. The man is suffering from arterial hypertension, receives antihypertensive therapy. During routine transthoracic echocardiography, a hyperechoic structure with a size of 9.5 x 0.9 cm was found in the right atrium and right ventricle. Chest computed tomography with contrast enhancement revealed signs of bone cement in the right atrium and right ventricle, in the right upper lobe artery, in the branches of the upper lobe artery, in the paravertebral venous plexuses. Considering the duration of the disease, the stable condition, the absence of clinical manifestations and disorders of intracardiac hemodynamics, it was decided to refrain from surgical treatment. Antiplatelet therapy and dynamic observation were recommended. Conclusion Percutaneous vertebroplasty is a modern minimally invasive surgical procedure for the treatment of degenerative-dystrophic diseases of the spine. However, the cement can penetrate into the paravertebral veins and migrate to the right chambers of the heart and the pulmonary artery. This clinical case demonstrates asymptomatic cement embolism of the right chambers of the heart and pulmonary artery after percutaneous vertebroplasty, detected incidentally during routine echocardiography. Abstract P686 Figure.


Sign in / Sign up

Export Citation Format

Share Document