Airway changes after fixed functional appliance treatment in children with and without morphologic deviations of the upper spine: A 3-dimensional CBCT study

Author(s):  
Yousef Abdalla ◽  
Stavros Kiliaridis ◽  
Liselotte Sonnesen
2016 ◽  
Vol 50 (2) ◽  
pp. 128-129
Author(s):  
Abhishek Choudhary ◽  
Amitabh Kallury ◽  
Chandresh Shukla ◽  
Ankur Chaukse

2018 ◽  
Vol 12 (1) ◽  
pp. 296-302
Author(s):  
Irina Stupar ◽  
Enver Yetkiner ◽  
Daniel Wiedemeier ◽  
Thomas Attin ◽  
Rengin Attin

Background:Lateral Cephalometric Radiographs (LCR) are a common decision-making aid in orthodontic treatment planning and are routinely used in clinical practice. The aim of this present study was to test the null hypothesis that LCR evaluation does not alter specific components of orthodontic treatment planning in Class II patients.Materials and Methods:Records of 75 patients, who had been treated at the Department of Orthodontics, Centre of Dental Medicine, University of Zurich comprised the study material. Inclusion criteria were: (1) adolescents between the age of 12-15, (2) permanent dentition with Class II buccal segment relationship (3) absence of craniofacial and dento-alveolar malformations. Fifteen orthodontists from the dental faculties of Istanbul University, Istanbul and Ege University, Izmir filled out Likert-type linear scale questionnaires without knowing that they would repeat the same procedure with and without LCRs at two different time points. Equivalence and clinical relevance were assessed using (%95 CI) Wilcoxon signed rank tests.Results:Extraction decision did not differ between groups (p=0.68). Preference of functional appliance use (p=0.006) and inter-maxillary fixed functional appliance (p=0.043) was different among groups.Conclusion:LCR evaluation has minor influence on treatment planning procedure of Class II patients. It might be beneficial to consider its prescription not in a routine manner but as a supplementary tool considering possible reduction of radiation exposure.


2016 ◽  
Vol 50 (2) ◽  
pp. 128-129
Author(s):  
Abhishek Choudhary ◽  
Amitabh Kallury ◽  
Chandresh Shukla ◽  
Ankur Chaukse

2009 ◽  
Vol 79 (6) ◽  
pp. 1095-1101 ◽  
Author(s):  
Koji Taira ◽  
Shoichiro Iino ◽  
Takeshi Kubota ◽  
Tomohiro Fukunaga ◽  
Shouichi Miyawaki

Abstract Introduction: To test the hypothesis that mandibular advancement with the use of a fixed functional appliance combined with prohibition of labial movement of the lower incisors will have no effect on mandibular growth in growing rats. Materials and Methods: Fifteen 4-week-old male rats were divided into fixed, unfixed, and control groups (n = 5, each). Bite-jumping appliances were used in the fixed and unfixed groups. Sites of bone perforation and the lower incisors were connected with ligature wires in the fixed group. The ramus height, mandibular length, and inclination of lower incisors were examined for 4 weeks, and those values were compared among five intervals and three groups by through one-way analysis of variance models and the Bonferroni multiple comparison test for post hoc comparison. Results: Increases in ramus height and mandibular length during the experimental period were 1.5 mm and 2.5 mm in the fixed group, 1 mm and 1.5 mm in the unfixed group, and 1.2 mm and 1.9 mm in the control group, respectively. Growth of ramus height and growth of mandibular length in the fixed group were greater than in the unfixed and control groups during the experimental period. The inclination of lower incisors in the unfixed group was increased 8.0 degrees throughout the experimental period, which differed from results obtained in the other groups. Conclusions: Mandibular growth was accelerated effectively before and during the pubertal period in rats by mandibular advancement with a fixed functional appliance combined with prohibition of labial movement of the lower incisor.


2017 ◽  
Vol 7 ◽  
pp. 87-93
Author(s):  
Harshal Ashok Patil ◽  
Pawankumar Dnyandeo Tekale ◽  
Veerendra V. Kerudi ◽  
Jitendra S. Sharan ◽  
Ratnadip Arunrao Lohakpure ◽  
...  

ObjectiveThe study conducted to assess the effects of a fixed functional appliance (Forsus Fatigue Resistant Device; 3M Unitek, Monrovia, CA, USA) on the mandible with three-dimensional (3D) finite element stress analysis.Materials and MethodsA 3D finite element model of mandible with miniplate at mandibular symphysis was prepared using SolidEdge software along with the plate geometry. The changes were deliberated with the finite element method, in the form of highest von Mises stress and maximum principal stress regions.ResultsMore areas of stress were seen in the model of the mandible at cortical bone in canine region at bone and miniplate interface.ConclusionsThis fixed functional appliance studied by finite element model analysis caused more von Mises stress and principal stress in both the cortical bone and the condylar region.


Sign in / Sign up

Export Citation Format

Share Document