Parametric study on the effect of using cold thermal storage energy of phase change material on the performance of air-conditioning unit

2018 ◽  
Vol 230 ◽  
pp. 1380-1402 ◽  
Author(s):  
M.A. Said ◽  
Hamdy Hassan
2020 ◽  
Vol 148 ◽  
pp. 987-1001 ◽  
Author(s):  
Pouyan Talebizadeh Sardari ◽  
Donald Giddings ◽  
David Grant ◽  
Mark Gillott ◽  
Gavin S. Walker

2021 ◽  
Vol 16 (1) ◽  
pp. 032-041
Author(s):  
Pradeep N ◽  
Somesh Subramanian S

Thermal energy storage through phase change material has been used for wide applications in the field of air conditioning and refrigeration. The specific use of this thermal storage has been for energy storage during low demand and release of this energy during peak loads with potential to provide energy savings due to this. The principle of latent heat storage using phase change materials (PCMs) can be incorporated into a thermal storage system suitable for using deep freezers. The evaporator is covered with another box which has storage capacity or passage through phase change material. The results revealed that the performance is increased from 3.2 to 3.5 by using PCM.


2018 ◽  
Vol 63 (4) ◽  
pp. 158-160 ◽  
Author(s):  
V. A. Levin ◽  
N. A. Lutsenko ◽  
S. S. Fetsov

Author(s):  
Ben Xu ◽  
Peiwen Li ◽  
Cholik Chan

With a large capacity thermal storage system using phase change material (PCM), Concentrated Solar Power (CSP) is a promising technology for high efficiency of solar energy utilization. In a thermal storage system, a dual-media thermal storage tank is typically adopted in industry for the purpose of reducing the use of the heat transfer fluid (HTF). While the dual-media sensible heat storage system has been well studied, a dual-media latent heat storage system (LHSS) still needs more attention and study; particularly, the sizing of volumes of storage tanks considering actual operation conditions is of significance. In this paper, a strategy for LHSS volume sizing is proposed, which is based on computations using an enthalpy-based 1D model. One example of 60MW solar thermal power plant with 35% thermal efficiency is presented. In the study, potassium hydroxide (KOH) is adopted as PCM and Therminol VP-1 is used as HTF. The operational temperatures of the storage system are 390°C and 310°C, respectively for the high and low temperatures. The system is assumed to operate for 100 days with 6 hours charge and 6 hours discharge every day. From the study, the needed height of the thermal storage tank is calculated from using the strategy of tank sizing. The method for tank volume sizing is of significance to engineering application.