Performance investigation of regenerative total heat exchanger with periodic flow

2018 ◽  
Vol 130 ◽  
pp. 1319-1327 ◽  
Author(s):  
Chih-Chung Chang ◽  
Jyun-De Liang ◽  
Sih-Li Chen
1964 ◽  
Vol 86 (2) ◽  
pp. 105-117 ◽  
Author(s):  
G. D. Bahnke ◽  
C. P. Howard

A numerical finite-difference method of calculating the effectiveness for the periodic-flow type heat exchanger accounting for the effect of longitudinal heat conduction in the direction of fluid flow is presented. The method considers the metal stream in crossflow with each of the gas streams as two separate but dependent heat exchangers. To accommodate the large number of divisions necessary for accuracy and extrapolation to zero element area, use was made of a general purpose digital computer. The values of the effectiveness thus obtained are good to four significant figures while those values for the conduction effect are good to three significant figures. The exchanger effectiveness and conduction effect have been evaluated over the following range of dimensionless parameters. 1.0⩾Cmin/Cmax⩾0.901.0⩽Cr/Cmin⩽∞1.0⩽NTU0⩽1001.0⩾(hA)*⩾0.251.0⩾As*⩾0.250.01⩽λ⩽0.32


2020 ◽  
Vol 205 ◽  
pp. 05024
Author(s):  
Mithun Mandal ◽  
Ramakrishna Bag

Geothermal energy is one of the potential energy resources to meet future energy demand keeping environmental pollution under control. This paper presents the use of geothermal energy for space heating from energy pile. An energy pile with a single U tube heat exchanger of polyethylene (PE) pipe was modeled in this study. The effect of pile and heat exchanger properties on the total heat extraction was studied by the finite element analysis using COMSOL Multiphysics. The 3D model was developed and validated based on the literature reported results of an experimental thermal performance of a borehole equipped with a single and double U tube heat exchanger. Tetrahedral elements were considered for simulation of a 3D model. The model of a single energy pile of certain dimensions with different soil layers was considered, each soil layers were associated with different temperature. The effect of various parameters such as the length of concrete pile, the diameter of concrete pile, the thickness of U pipe, the inner diameter of U pipe and velocity of fluid inside the U pipe on amount of heat extraction was studied for an energy pile equipped with a single U tube heat exchanger. It was observed that the most influential parameters in increasing the outlet temperature of the heat exchanger loop are the diameter of the concrete pile, the inner diameter of U pipe and the velocity of fluid inside the U pipe.


2014 ◽  
Vol 20 (7) ◽  
pp. 731-737 ◽  
Author(s):  
Fu-Jen Wang ◽  
Meng-Chieh Lee ◽  
Tong-Bou Chang ◽  
Yong-Sheng Chen ◽  
Ron-Chin Jung

1964 ◽  
Vol 86 (2) ◽  
pp. 121-126 ◽  
Author(s):  
J. R. Mondt

Design, fabrication, and operation experience with periodic-flow heat exchangers used in General Motors regenerative vehicular gas turbines has indicated that analysis techniques available in published reports are too restrictive for accurate performance and thermal distortion calculations. The design usefulness of previously published analyses is somewhat limited because fluid and metal temperature distributions are not part of the calculated results. These distributions are required for primary seal matching and core and structural thermal stress calculations. A nodal analysis has been accomplished at the General Motors Research Laboratories and a type of finite difference solution obtained for the periodic-flow heat exchanger. This solution can be used to study the effects of longitudinal thermal conduction, variable heat-transfer coefficients, finite rotation, and provides temperature distributions as functions of time and space for transient as well as “steady-state.” This has been checked both with available solutions for more simplified cases and some experimental measured results for periodic flow heat exchangers designed and built as part of the General Motors vehicular regenerative gas turbine program. A brief outline of the calculation procedures, program capabilities, and some calculated results is presented. This includes temperature distributions for periodic-flow heat-exchanger parameters encountered in the vehicular regenerator application.


2013 ◽  
Vol 2013 (1) ◽  
pp. 4362
Author(s):  
Fu-Jen Wang ◽  
Meng-Chieh Lee ◽  
Rong-Chin Jung ◽  
Yong-Sheng Chen ◽  
You-De Ke

Sign in / Sign up

Export Citation Format

Share Document