Raman spectroscopy and X-ray photo-spectroscopy analysis of graphite media irradiated at low doses

2019 ◽  
Vol 147 ◽  
pp. 105-112 ◽  
Author(s):  
D.A. Bradley ◽  
Z. Siti Rozaila ◽  
M.U. Khandaker ◽  
K.S. Almugren ◽  
Worawat Meevasana ◽  
...  
Author(s):  
D. J. Bailey ◽  
M. C. Stennett ◽  
J. Heo ◽  
N. C. Hyatt

AbstractSEM–EDX and Raman spectroscopy analysis of radioactive compounds is often restricted to dedicated instrumentation, within radiological working areas, to manage the hazard and risk of contamination. Here, we demonstrate application of WetSEM® capsules for containment of technetium powder materials, enabling routine multimodal characterisation with general user instrumentation, outside of a controlled radiological working area. The electron transparent membrane of WetSEM® capsules enables SEM imaging of submicron non-conducting technetium powders and acquisition of Tc Lα X-ray emission, using a low cost desktop SEM–EDX system, as well as acquisition of good quality μ-Raman spectra using a 532 nm laser.


2021 ◽  
Author(s):  
Sneha Pravin Kandare ◽  
V. N. Bhoraskar ◽  
A. B . Phatangare ◽  
Rekha Rao ◽  
Mala Rao ◽  
...  

Abstract Microwave synthesized nano sized Cu2ZnSnS4 (CZTS) powder was irradiated with 6 MeV electrons, to investigate stability under radiation. The structural, optical, vibrational and morphological properties were explored using X-ray diffraction, UV-Visible spectroscopy, Raman spectroscopy and Scanning Electron Microscope (SEM).The irradiated sample shows significant change in properties when compared to the pristine sample. X ray peak broadening analysis has been used to estimate the crystallite size and lattice strain. Raman spectroscopy analysis confirms the transition of ordered kesterite to disordered kesterite phase after electron irradiation at electron fluence of 4 x1015 e-/cm2. CZTS nano-particles having hierarchical flower like morphology starts agglomerating after electron irradiation as observed from SEM images. The sample did not amorphize upto the highest fluence 4 x 1015 e-/cm2 employed in this study.


2005 ◽  
Vol 126 ◽  
pp. 101-105 ◽  
Author(s):  
B. Moulin ◽  
L. Hennet ◽  
D. Thiaudière ◽  
P. Melin ◽  
P. Simon

2018 ◽  
Vol 69 (7) ◽  
pp. 1714-1717
Author(s):  
Roxana Ionela Vasluianu ◽  
Norina Consuela Forna ◽  
Elena Raluca Baciu ◽  
Mirela Zaltariov ◽  
Lavinia Vasiliu ◽  
...  

The anti-erosion effect of fluoride on the enamel surface was investigated by ATR-FTIR, SEM and EDX techniques. Four extracted teeth (two incisors and two premolars) were initially bleached with carabamide peroxide and etched with ortho-phosphoric acid then fluoride treatment was applied. Significant differences in enamel composition and morphology were observed providing the effect of fluoride application in remineralization of teeth. Infrared spectroscopy was employed to probe the changes in enamel structure. Scanning electron microscopy/energy dispersive X-ray spectroscopy analysis revealed higher content in F of teeth enamel. Morphology changes revealed a re-mineralization of enamel surface after the treatment with fluoride gel.


2016 ◽  
Vol 5 (4) ◽  
pp. 308-317
Author(s):  
Hagos Tesfay ◽  
Erika S. Bronze-Uhle ◽  
Augusto Batagin-Neto ◽  
Anna C. Véron ◽  
Thomas Geiger ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document