Preparation of well-adhered γ-Al2O3 washcoat on metallic wire mesh monoliths by electrophoretic deposition

2007 ◽  
Vol 253 (6) ◽  
pp. 3303-3310 ◽  
Author(s):  
Hong Sun ◽  
Xie Quan ◽  
Shuo Chen ◽  
Huimin Zhao ◽  
Yazhi Zhao
2007 ◽  
Vol 76 (24) ◽  
Author(s):  
J. Bravo-Abad ◽  
L. Martín-Moreno ◽  
F. J. García-Vidal ◽  
E. Hendry ◽  
J. Gómez Rivas

1986 ◽  
Vol 108 (3) ◽  
pp. 446-449 ◽  
Author(s):  
G. A. Karim ◽  
M. G. Kibrya

The combustion of a homogeneous lean methane-air stream was investigated in a vertical, cylindrical combustor of 150 mm diameter in the presence of a metallic wire mesh. Eight metallic materials were deposited in turn onto a stainless steel wire mesh by electroplating. The potential improvement in the lean blowout limit due to catalytic effects was established separately from those due to the thermal and aerodynamic contributions of the wire mesh and its holder ring. The effectiveness of the various metallic surfaces tested in the lean combustion of methane was in the following descending order: Pt → Cu → Ag → brass → Cr → Cd → Ni → stainless steel. Moreover, it was confirmed that hydrogen was more sensitive to catalytic effects extending to relatively lower temperatures than methane.


2022 ◽  
Vol 170 ◽  
pp. 108599
Author(s):  
Xin Xue ◽  
Yuhan Wei ◽  
Fang Wu ◽  
Hongbai Bai ◽  
Chunhong Lu ◽  
...  

2013 ◽  
Vol 57 (2) ◽  
pp. 690-697 ◽  
Author(s):  
Zenghui Zhao ◽  
Yoav Peles ◽  
Michael K. Jensen
Keyword(s):  

Swiss Surgery ◽  
2003 ◽  
Vol 9 (6) ◽  
pp. 283-288
Author(s):  
Maurer ◽  
Stamenic ◽  
Stouthandel ◽  
Ackermann ◽  
Gonzenbach

Aim of study: To investigate the short- and long-term outcome of patients with isolated lateral malleolar fracture type B treated with a single hemicerclage out of metallic wire or PDS cord. Methods: Over an 8-year period 97 patients were treated with a single hemicerclage for lateral malleolar fracture type B and 89 were amenable to a follow-up after mean 39 months, including interview, clinical examination and X-ray controls. Results: The median operation time was 35 minutes (range 15-85 min). X-ray controls within the first two postoperative days revealed an anatomical restoration of the upper ankle joint in all but one patient. The complication rate was 8%: hematoma (2 patients), wound infection (2), Sudeck's dystrophy (2) and deep vein thrombosis (1). Full weight-bearing was tolerated at median 6.0 weeks (range 2-26 weeks). No secondary displacement, delayed union or consecutive arthrosis of the upper ankle joint was observed. All but one patient had restored symmetric joint mobility. Ninety-seven percent of patients were satisfied or very satisfied with the outcome. Following bone healing, hemicerclage removal was necessary in 19% of osteosyntheses with metallic wire and in none with PDS cord. Conclusion: The single hemicerclage is a novel, simple and reliable osteosynthesis technique for isolated lateral type B malleolar fractures and may be considered as an alternative to the osteosynthesis procedures currently in use.


1965 ◽  
Vol 15 (1) ◽  
pp. 40-48
Author(s):  
D. R. Brown ◽  
F. W. Salt

Sign in / Sign up

Export Citation Format

Share Document