scholarly journals Self sliding growth guidance for early-onset scoliosis: Clinical and radiological results after a minimum of five years (5-13) of follow-up

2021 ◽  
Vol 1 ◽  
pp. 100146
Author(s):  
Mustafa Eltayep ◽  
Recep Dincer ◽  
Ahmet Ates ◽  
Sina Coskun ◽  
Ugur Tasci ◽  
...  
Author(s):  
Justin V.C. Lemans ◽  
Sebastiaan P.J. Wijdicks ◽  
René M. Castelein ◽  
Moyo C. Kruyt

2019 ◽  
Vol 39 (8) ◽  
pp. 400-405 ◽  
Author(s):  
John T. Wilkinson ◽  
Chad E. Songy ◽  
David B. Bumpass ◽  
Francis L. McCullough ◽  
Richard E. McCarthy

2019 ◽  
Vol 28 (8) ◽  
pp. 1073-1077
Author(s):  
Grzegorz Miękisiak ◽  
Krzysztof Koltowski ◽  
Piotr Menartowicz ◽  
Zygmunt Oleksik ◽  
Dariusz Kotulski ◽  
...  

2021 ◽  
Vol 1 ◽  
pp. 100148
Author(s):  
Sinan Kahraman ◽  
Sina Coskun ◽  
Recep Dincer ◽  
Ahmet Ates ◽  
Mustafa Eltayep ◽  
...  

2021 ◽  
Author(s):  
Mandar Deepak Borde ◽  
Sarang Sapare ◽  
Emile Schutgens ◽  
Chadi Ali ◽  
Hilali Noordeen

Abstract Study design A cross-sectional retrospective Level 3 study. Objective To study the serum levels of Titanium and Aluminium ions in patients operated using the magnetically controlled growing rod (MCGR) system. Summary of background data 14 consecutive patients of early onset scoliosis with varying etiology managed with MCGR system with a minimum follow-up of 24 months were selected for the study. The group consisted of two boys (14.3%) and 12 girls (85.7%). The average age of the patients at the time of surgery was 10.4 years (5–15 years). The average period of follow-up was 43.7 months (28–79 months). After informed consent of the subjects and their caretakers, serum levels of titanium and aluminium were measured. These levels were then assessed with regards to the number of screws used, number of distractions and complications. Methods The concentration of titanium and aluminium ions in the serum was measured using high resolution inductively coupled plasma mass spectrometry. Results For the sake of ease of assessment, patients were divided into three etiology-based groups—idiopathic (n = 6), neuromuscular (n = 2) and syndromic (n = 6). The mean serum titanium level was 15.9 μg/L (5.1–28.2 μg/L) while that of aluminium was 0.1 μmol/L (0.1–0.2 μmol/L). Of the 14 patients, 2 (14.2%) patients had mechanical failure (actuator pin dysfunction), 3 (21.4%) had rod breakage requiring revision surgery and one patient (7.1%) had surgical site infection managed with appropriate antibiotics. Patients undergoing revision for rod breakage did not show any metallosis of the tissues during surgery. Conclusion Analysis of patients with scoliosis operated using the magnetic growing rod system concludes that it is accompanied by presence of titanium in the blood but whether clinically significant or not needs to be ascertained by comparison of preoperative and postoperative blood concentrations of the titanium ions in individual subjects. The aluminium ion concentration remains within normal limits. Though implant malfunction may raise the titanium levels in the blood, its clinical significance needs to be determined. The aluminium levels are not affected irrespective to the presence or absence of complications. The long-term effects of raised titanium levels in the blood also warrant further prospective studies designed for precise and deeper analyses.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Ziyang Liu ◽  
Tie Liu ◽  
Yong Hai ◽  
Lingyun Wu ◽  
Junrui Jonathan Hai ◽  
...  

Abstract Background Obtaining and maintaining final shoulder balance after the entire treatment course is essential for early-onset scoliosis (EOS) patients. The relatively small number of growing-rod (GR) graduates who complete final fusion has resulted in an overall paucity of research on the GR treatment of EOS and a lack of research on the shoulder balance of EOS patients during GR treatment. Methods Twenty-four consecutive patients who underwent GR treatment until final fusion were included. Radiographic shoulder balance parameters, including the radiographic shoulder height (RSH), clavicle angle (CA), and T1 tilt angle (T1T), before and after each step of the entire treatment were measured. Shoulder balance changes from GR implantation to the last follow-up after final fusion were depicted and analysed. Demographic data, surgical-related factors, and radiographic parameters were analysed to identify risk factors for final shoulder imbalance. The shoulder balance of patients at different time points was further analysed to explore the potential effect of the series of GR treatment steps on shoulder balance. Results The RSH showed substantial improvement after GR implantation (P = 0.036), during the follow-up period after final fusion (P = 0.021) and throughout the entire treatment (P = 0.011). The trend of change in the CA was similar to that of the RSH, and the T1T improved immediately after GR implantation (P = 0.037). Further analysis indicated that patients with shoulder imbalance before final fusion showed significantly improved shoulder balance after fusion (P = 0.045), and their RSH values at early postfusion and the final follow-up did not show statistically significant differences from those in the prefusion shoulder balance group (P > 0.05). Early postfusion shoulder imbalance (odds ratio (OR): 19.500; 95% confidence interval (CI) = 1.777–213.949; P = 0.015) was identified as an independent risk factor for final shoulder imbalance. Conclusions Shoulder balance could be improved by GR implantation but often changes during the multistep lengthening process, and the final result is relatively unpredictable. Final fusion could further adjust the prefusion shoulder imbalance. Focusing on the prefusion shoulder balance of GR graduates and providing patients with early shoulder balance after fusion might be necessary.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Nicola Piolanti ◽  
Lorenzo Andreani ◽  
Paolo Domenico Parchi ◽  
Enrico Bonicoli ◽  
Francesco Niccolai ◽  
...  

Acetabular cup loosening is associated with pain, reduced function, and instability of the implant. If such event happens while the femoral implant is in a satisfactory position and is well fixed to the bone, isolated acetabular revision surgery is indicated. The aim of this single-center retrospective study was to evaluate the clinical and radiological results over the medium term (12-month follow-up mean 36, max 60) of isolated acetabular revisions surgery using a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head (>32). 33 patients were enrolled. We collect any relevant data from the clinical board. Routine clinical and radiographic examinations were performed preoperatively; the postoperative follow-up was made at 1, 3, and 6 months and yearly thereafter. At the last available follow-up, we report satisfactory improvement of functional scores in all the patients; 2 patients (6.1%) showed thigh pain and only 4 hips (12.11%) presented mild groin pain; all the femoral components are well fixed and there were no potential or pending rerevisions. With bias due to the follow-up and to the retrospective design of the study, we report clinical, functional, and radiological satisfactory results.


Sign in / Sign up

Export Citation Format

Share Document