A general rate model approach for the optimization of the core radius fraction for multicomponent isocratic elution in preparative nonlinear liquid chromatography using cored beads

2011 ◽  
Vol 66 (15) ◽  
pp. 3531-3539 ◽  
Author(s):  
Tingyue Gu ◽  
Mingqing Liu ◽  
Kwok-Shun C. Cheng ◽  
Senthilkumar Ramaswamy ◽  
Chen Wang
2019 ◽  
Vol 16 ◽  
Author(s):  
Joanna Wittckind Manoel ◽  
Camila Ferrazza Alves Giordani ◽  
Livia Maronesi Bueno ◽  
Sarah Chagas Campanharo ◽  
Elfrides Eva Sherman Schapoval ◽  
...  

Introduction: Impurity analysis is an important step in the quality control of pharmaceutical ingredients and final product. Impurities can arise from drug synthesis or excipients and even at small concentrations may affect product efficacy and safety. In this work two methods using high performance liquid chromatography (HPLC) were developed and validated for the evaluation of besifloxacin and its impurity synthesis, with isocratic elution and another with gradient elution. Method: The analysis by HPLC in isocratic elution mode was performed using a cyano column maintained at 25 °C. The mobile phase was composed by 0.5% triethylamine (pH 3.0): acetonitrile (88:12 v/v) eluted at a flow rate of 1.0 ml/min with detection at 330 nm. The gradient elution method was carried out with the same column and mobile phase components only modifying the rate between organic and aqueous phase during analysis. The procedures have been validated according to internationally accepted guidelines, observing results within acceptable limits. Results: The methods presented were found to be linear in the 140 to 260 µg/ml range for besifloxacin and 0.3 to 2.3 µg/ml for an impurity named A. The limits of detection and quantification were respectively 0.07 and 0.3 µg/ml for impurity A, with a 20 µL injection volume. The precision achieved for all analyses performed provided RSD inter-day equal to 6.47 and 6.36% for impurity A with isocratic elution and gradient, respectively. The accuracy was higher than 99% and robustness exhibited satisfactory results. In the isocratic method an analysis time of 25 min and 15 min was obtained for gradient. For impurity A, the number of theoretical plates in the isocratic mode was about 5000 while in the gradient mode it was about 45000, hence, it made the column more efficient by changing the mobile phase composition during elution. In besifloxacin raw material and in pharmaceutical product used in this study, other related impurities were present but but impurity A was searched for and not detected Conclusion: The proposed methods can be applied for quantitative determination of impurities in the analysis of the besifloxacin raw material, as well as in ophthalmic suspension of the drug, considering the quantitation limit.


2021 ◽  
Vol 2 (1) ◽  
pp. 120-126
Author(s):  
Elida Elfi Barus ◽  
M.Yasir Nasution ◽  
Andri Soemitra

In the Covid Pandemic 19, sharia cooperatives must be a solution for the welfare of their members and the UMKM that they support so that they can move up in class, but how if it is difficult to access, therefore sharia cooperatives must be digital-based and include collaborating with fintech. This study tries to answer the problems that occur, strategies, and stakeholders involved in the development of Islamic cooperatives in collaboration with sharia fintech in Indonesia using the Interpretive Structural Model (ISM) approach. The core problem faced in developing sharia cooperatives in collaboration with sharia fintech is the lack of education and promotion of Islamic financial institutions collaboration, especially in sharia cooperatives with sharia fintech (E9), which initially became competitors to financial institutions because they were very flexible and fast and have become OJK's instructions that fintech must collaborate with financial institutions including sharia ones. Furthermore, it can be suggested for legislators, actors and drafter to constantly monitor and improve the process in the context of the progress and welfare of cooperatives and SMEs in Indonesia.


1995 ◽  
Vol 163 ◽  
pp. 262-270
Author(s):  
A. M. Cherepashchuk

New spectrophotometric, photometric and polarimetric observations of V444 Cygni confirm the basic conclusion that the WN5 star has a small core radius (rc < 4 R⊙) and a high core temperature (Tc > 60 000 K), which are characteristic of massive helium stars. Values of rc < 3 — 6 R⊙ and Tc > 70 000 — 90 000 K for the core of the WN7 star in the Cygnus X-3 system agree well with this conclusion. A clumping structure of WR winds is suggested. X-ray observations of colliding winds in WR+O binaries suggest radial expansion and anomalous chemical composition of WR winds.


Sign in / Sign up

Export Citation Format

Share Document