A novel high-throughput liquid chromatography assay for Carbohydrate-Deficient Transferrin (CDT) based on flow-modulated isocratic elution and terbium-induced fluorescence

2021 ◽  
pp. 122942
Author(s):  
Giacomo Musile ◽  
Elio Franco De Palo ◽  
Romolo Marco Dorizzi ◽  
Kseniia Shestakova ◽  
Svetlana Appolonova ◽  
...  
2019 ◽  
Vol 16 ◽  
Author(s):  
Joanna Wittckind Manoel ◽  
Camila Ferrazza Alves Giordani ◽  
Livia Maronesi Bueno ◽  
Sarah Chagas Campanharo ◽  
Elfrides Eva Sherman Schapoval ◽  
...  

Introduction: Impurity analysis is an important step in the quality control of pharmaceutical ingredients and final product. Impurities can arise from drug synthesis or excipients and even at small concentrations may affect product efficacy and safety. In this work two methods using high performance liquid chromatography (HPLC) were developed and validated for the evaluation of besifloxacin and its impurity synthesis, with isocratic elution and another with gradient elution. Method: The analysis by HPLC in isocratic elution mode was performed using a cyano column maintained at 25 °C. The mobile phase was composed by 0.5% triethylamine (pH 3.0): acetonitrile (88:12 v/v) eluted at a flow rate of 1.0 ml/min with detection at 330 nm. The gradient elution method was carried out with the same column and mobile phase components only modifying the rate between organic and aqueous phase during analysis. The procedures have been validated according to internationally accepted guidelines, observing results within acceptable limits. Results: The methods presented were found to be linear in the 140 to 260 µg/ml range for besifloxacin and 0.3 to 2.3 µg/ml for an impurity named A. The limits of detection and quantification were respectively 0.07 and 0.3 µg/ml for impurity A, with a 20 µL injection volume. The precision achieved for all analyses performed provided RSD inter-day equal to 6.47 and 6.36% for impurity A with isocratic elution and gradient, respectively. The accuracy was higher than 99% and robustness exhibited satisfactory results. In the isocratic method an analysis time of 25 min and 15 min was obtained for gradient. For impurity A, the number of theoretical plates in the isocratic mode was about 5000 while in the gradient mode it was about 45000, hence, it made the column more efficient by changing the mobile phase composition during elution. In besifloxacin raw material and in pharmaceutical product used in this study, other related impurities were present but but impurity A was searched for and not detected Conclusion: The proposed methods can be applied for quantitative determination of impurities in the analysis of the besifloxacin raw material, as well as in ophthalmic suspension of the drug, considering the quantitation limit.


2013 ◽  
Vol 59 (10) ◽  
pp. 1514-1522 ◽  
Author(s):  
Morteza Razavi ◽  
Lisa DS Johnson ◽  
Julian J Lum ◽  
Gary Kruppa ◽  
N Leigh Anderson ◽  
...  

BACKGROUND Biomarker validation remains one of the most challenging constraints to the development of new diagnostic assays. To facilitate biomarker validation, we previously developed a chromatography-free stable isotope standards and capture by antipeptide antibodies (SISCAPA)-MALDI assay allowing rapid, high-throughput quantification of protein analytes in large sample sets. Here we applied this assay to the measurement of a surrogate proteotypic peptide from protein C inhibitor (PCI) in sera from patients with prostate cancer. METHODS A 2-plex SISCAPA-MALDI assay for quantification of proteotypic peptides from PCI and soluble transferrin receptor (sTfR) was used to measure these peptides in 159 trypsin-digested sera collected from 51 patients with prostate cancer. These patients had been treated with radiation with or without neoadjuvant androgen deprivation. RESULTS Patients who experienced biochemical recurrence of prostate cancer showed decreased serum concentrations of the PCI peptide analyte within 18 months of treatment. The PCI peptide concentrations remained increased in the sera of patients who did not experience cancer recurrence. Prostate-specific antigen concentrations had no predictive value during the same time period. CONCLUSIONS The high-throughput, liquid chromatography–free SISCAPA-MALDI assay is capable of rapid quantification of proteotypic PCI and sTfR peptide analytes in complex serum samples. Decreased serum concentrations of the PCI peptide were found to be related to recurrence of prostate cancer in patients treated with radiation with or without hormone therapy. However, a larger cohort of patients will be required for unequivocal validation of the PCI peptide as a biomarker for clinical use.